AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sorteberg, A.
Right arrow Articles by Strother, C. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sorteberg, A.
Right arrow Articles by Strother, C. M.

Effect of Guglielmi Detachable Coil Placement on Intraaneurysmal Pressure: Experimental Study in Canines

Angelika Sorteberga, Wilhelm Sorteberga, Aquilla S. Turka, Alan Rappea, Per Hj Nakstada and Charles M. Strothera

a From the Department of Neurosurgery (A.S., W.S.) and Department of Radiology, Section of Neuroradiology (P.H.N.), Rikshospitalet, The National Hospital, Oslo, Norway; Department of Radiology (A.S.T., A.R., C.M.S.), University of Wisconsin Health Sciences Center, Madison.



View larger version (152K):

[in a new window]
 
FIG 1. DSA image shows a bifurcation and a lateral aneurysm. The pressure wire is in place in the dome of the bifurcation aneurysm. The pressure sensor is at the junction of the radiopaque and nonradiopaque portion of the wire (arrow). A dime is taped to the neck of the animal



View larger version (23K):

[in a new window]
 
FIG 2. Pressure trace in the dome of a lateral aneurysm during injection of 30 mL/s saline over 2 s. The pressure amplitude, mean pressure, upstroke, and downstroke of the saline injection are indicated



View larger version (35K):

[in a new window]
 
FIG 3. Pressures observed during injections of 10, 20, and 30 mL saline over 1 or 2 s. The volume, not the duration of injection, correlated with the magnitude of the pressure increases



View larger version (32K):

[in a new window]
 
FIG 4. Pressures in the parent artery versus the dome of the aneurysm during the injection of saline at 20 mL/s



View larger version (41K):

[in a new window]
 
FIG 5. Pressures in the dome of an aneurysm during injections of 10, 20, and 30 mL of saline over 2 s before and after complete coil placement. The mean pressure was unaffected by coil placement, whereas the pressure amplitude was attenuated



View larger version (33K):

[in a new window]
 
FIG 6. Pressure trace from the dome of an aneurysm before GDC coiling (top) and after complete GDC placement (bottom) during injections of 10 mL of saline over 2 s. Neither baseline pressure nor the induced pressure increase was reduced after coiling. The upstroke of the pressure increase decelerates after saline injection (dotted lines)