AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ogata, T.
Right arrow Articles by Minematsu, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ogata, T.
Right arrow Articles by Minematsu, K.

Transcranial Color-Coded Real-Time Sonographic Criteria for Occlusion of the Middle Cerebral Artery in Acute Ischemic Stroke

Toshiyasu Ogataa, Kazumi Kimuraa, Makoto Nakajimaa, Kouichi Ikenoa, Hiroaki Naritomia and Kazuo Minematsua

a From the Department of Medicine, Cerebrovascular Division, National Cardiovascular Center, Osaka, Japan



View larger version (111K):

[in a new window]
 
FIG 1. Left anteroposterior carotid angiograms in representative cases evaluated with cerebral angiography and TCCS. Y axis is represented blood flow velocity (cm/s). Left image shows occlusion of the horizontal portion of the left MCA (a). Occlusion site overlies the external carotid artery branch. Doppler waveforms of the left (b) and right (c) MCAs show EDVs of 14.5 and 49.9 cm/s, respectively. Right image shows occlusion of the branch in the left MCA (a). Doppler waveforms of the left (b) and right (c) MCAs show EDVs of 18.2 and 44.6 cm/s, respectively.



View larger version (10K):

[in a new window]
 
FIG 2. Scattergrams. Top, Mean EDVs (±2 SDs) for the control, MO, and MB groups are 40.5 ± 11.5, 12.2 ± 3.6, and 19.6 ± 4.8, respectively (P < .001, Scheffé test). Bottom, Mean end-diastolic ratios (±2 SDs) for the control, MO, and MB groups are 1.2 ± 0.1, 4.2 ± 1.5, and 1.8 ± 0.5, respectively (P < .001, Scheffé test).



View larger version (10K):

[in a new window]
 
FIG 3. Sensitivity-specificity curves.

A, Predicting MO or MB by EDV. Optimal threshold value for EDV is 25 cm/s.

B, Differentiating MO from MB by the end-diastolic ratio. Optimal threshold value for the ratio is 2.7.



View larger version (16K):

[in a new window]
 
FIG 4. Algorithm for diagnosing MO and MB by using the EDV and end-diastolic ratio on TCCS.