The Cochlear-Carotid Interval: Anatomic Variation and Potential Clinical Implications
R.J. Younga,
D.R. Shatzkesc,
J.S. Babba and
A.K. Lalwanib
a Department of Radiology, Division of Neuroradiology, New York University Medical Center, New York, NY
b Department of Otolaryngology and Physiology and Neuroscience, New York University Medical Center, New York, NY
c Department of Radiology, Division of Head & Neck Radiology, St. Lukes Roosevelt Hospital Center, New York, NY

View larger version (52K):
[in a new window]
|
Fig. 1. Normal cochlea-carotid interval (CCI), measured on coronal CT images as the minimal distance from the basal turn of the cochlea to the carotid canal. Both sides are from a single patient.
A, Right CCI measures 2.1 mm (arrow).
B, Left CCI measures 1.0 mm (arrow).
C, 3D temporal bone reconstruction of a normal CCI shows the normal separation between the cochlea and carotid canal.
| |

View larger version (59K):
[in a new window]
|
Fig. 2. Case report: masked bone conduction thresholds are shown for a series of audiograms performed on September 8 (A), October 19 (B), November 11 (C), and December 2 (D).
A, The initial baseline audiogram demonstrated high-frequency sensorineural hearing loss (SNHL) that is symmetric and bilateral (dashed box).
B, Six weeks later, the patient complained of left-sided hearing loss and the audiogram revealed left-sided mid-tone SNHL (dashed box).
C, Three weeks later, when the patient presented with contralateral SNHL, the audiogram showed resolution of left-sided mid-tone SNHL and new right-sided mid-tone SNHL (dashed box).
D, Three weeks later, when the patient again presented with left-sided symptoms, the audiogram showed resolution of right-sided mid-tone SNHL and new left-sided mid-tone SNHL (dashed box). Subsequent audiogram was similar to the initial evaluation; however, the fluctuation continued.
| |

View larger version (64K):
[in a new window]
|
Fig. 3. Case report with mid-tone SNHL: coronal temporal bone CT images. Coronal CT (A) and (C) 3D reconstruction show right CCI to measure 0.2 mm (arrow). Coronal CT (B) and (D) 3D reconstruction show left CCI to measure 0.0 mm (arrow).
| |

View larger version (22K):
[in a new window]
|
Fig. 4. Audiogram from Modugno et als reported patient with bilateral dehiscence of the bony cochlea shows typical mid-tone SNHL that is identical to that seen in Fig 2. (Figure reproduced from Modugno GC, Brandolini C, Cappello I, et al. Bilateral dehiscence of the bony cochlear basal turn. Arch Otolaryngol Head Neck Surg 2004;130:142729. Copyright © 2004 American Medical Association, All rights reserved. Used with permission.)
| |