Published ahead of print on July 17, 2008
doi: 10.3174/ajnr.A1220
Origin of Synchronized Low-Frequency Blood Oxygen Level–Dependent Fluctuations in the Primary Visual Cortex
J.S. Andersona
a From the Department of Neuroradiology, University of Utah, Salt Lake City, Utah

View larger version (35K):
[in this window]
[in a new window]
|
Fig 1. Selection of regions of interest. A, Visual stimuli shown to right and left hemifields corresponding to activation in left and right visual cortices. Stimuli were flashed with alternating black and white regions (100% contrast) at 6 Hz, alternating between left and right images every 20 seconds for 4 minutes. B, Activation maps in 1 subject from previously mentioned stimulation. Activation in the primary and extrastriate visual cortex is seen on the left in red and on the right in green. The yellow box on the sagittal view shows the brain region acquired for BOLD sequences. C, Left visual cortex time series. Slightly >3% increase in BOLD signal intensity is seen averaged across the left primary visual cortex cluster. Three minutes of data are shown.
| |

View larger version (21K):
[in this window]
[in a new window]
|
Fig 2. Synchronized BOLD fluctuations. A, Time series data from 1 subject. Six minutes of data are shown. Traces represent average BOLD signal intensity from regions of interest in the bilateral primary visual cortex (V1), left LGN, and bilateral frontal eye fields (FEF). B, Cross-correlation analysis represents full 14-minute resting state data from regions listed previously. Bilateral V1 shows strong focal correlation, with similar but diminished correlation between V1 and LGN. No correlation is seen between V1 and FEF. Bilateral FEF show much broader temporal correlation. C, Summary resting state BOLD cross-correlation from 6 subjects. Green traces show cross-correlograms for individual subjects, and black traces show an average cross-correlogram across subjects (bilateral V1, n = 6; left V1-left LGN, n = 3; left V1-left FEF, n = 2, left FEF-right FEF: n = 2).
| |

View larger version (17K):
[in this window]
[in a new window]
|
Fig 3. Vascular low-pass filtering of neurovascular coupling. A, Data in the first column represent BOLD responses to a 6-Hz flashing radial checkerboard pattern turned ON and OFF at frequencies ranging from 0.01 to 0.5 Hz. Data in the second column represent BOLD responses to single flashes of 1 screen refresh duration (13 ms) of the same radial checkerboard pattern presented at frequencies ranging from 0.1 to 4 Hz. B, Peak-to-peak response for 1 period of the stimulus. Individual points plotted are responses from each subject of the amplitude of the BOLD response averaged across all cycles of stimulus presentation. Left and right hemifield responses are plotted as separate data points on the left and are averaged for each data point on the right. Error bars represent 1 standard error of the mean. C, Mean BOLD responses compared with baseline (blank screen stimulus), averaged across the entire trial for each frequency condition. Data points and error bars are as in Fig 3B.
| |

View larger version (11K):
[in this window]
[in a new window]
|
Fig 4. Frequencies present in spontaneous BOLD fluctuations in the primary visual cortex. A, Full-field (inset) and zoomed-in power spectra of resting-state BOLD fluctuations. Spectra are computed for each subject, normalized to the unit area under the curve, and averaged across subjects. Shaded regions represent ±1 standard error of the mean as a function of frequency. B, Superimposed vascular filtering data of Fig 3B and the resting-state power spectrum from Fig 4A. Frequencies between 0.05 and 0.2 Hz are under-represented if frequency distribution of spontaneous BOLD fluctuations arises from vascular filtering alone.
| |

View larger version (26K):
[in this window]
[in a new window]
|
Fig 5. Power in spontaneous BOLD fluctuations in resting and visual stimulation conditions. Resting state (blue) condition shows the shift of frequency distribution to higher frequencies compared with natural visual stimulation condition (red). Spectra are averaged across 6 subjects for each condition. Shaded areas represent standard error of the mean as a function of frequency across the population. The pair-wise t test for each frequency range (0–0.02 Hz and 0.02–0.05 Hz) indicates statistically significant differences between the 2 conditions for each of the 2 ranges.
| |