AJDRAJNR - American Journal of Neuroradiology

Published ahead of print on September 3, 2008
doi: 10.3174/ajnr.A1274

This Article
Free to Access This article has been Unlocked
Right arrow Abstract
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sasaki, M.
Right arrow Articles by Fujiwara, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sasaki, M.
Right arrow Articles by Fujiwara, S.

Tracer Delay–Insensitive Algorithm Can Improve Reliability of CT Perfusion Imaging for Cerebrovascular Steno-Occlusive Disease: Comparison with Quantitative Single-Photon Emission CT

M. Sasakia, K. Kudoa, K. Ogasawarab and S. Fujiwaraa

a Advanced Medical Research Center, Iwate Medical University, Morioka, Japan
b Department of Neurosurgery, Iwate Medical University, Morioka, Japan


Figure 1
View larger version (76K):
[in this window]
[in a new window]

 
Fig 1. CBF and MTT maps of a 70-year-old woman with occlusion of the right MCA. A and E, CTP with bSVD. B and F, CTP with sSVD. C and G, CTP with bMTF. D, Quantitative SPECT with 123I-IMP. AD, CBF. EG, MTT. AIF was obtained from the second portion of the left MCA. AC, E–G, CBF and MTT color maps on CTP appear different among the different deconvolution algorithms. BD, Images obtained by using sSVD (B) and bMTF (C) overestimate the decrease in CBF of the right MCA territory, compared with that generated by SPECT (D), whereas images using bSVD (A) correspond well with those using SPECT (D).


Figure 2
View larger version (16K):
[in this window]
[in a new window]

 
Fig 2. Absolute CBF values of the unaffected and affected MCA territories with different algorithms and different locations of AIFs. The ranges of the CBF obtained by bSVD in any conditions and those obtained by sSVD with the AIF on the unaffected MCA are significantly smaller than the corresponding ranges obtained by quantitative SPECT. However, those obtained by bMTF are significantly larger than those obtained by SPECT, particularly when the AIF is on the affected MCA. The CBF ranges obtained by sSVD with the AIF on the affected MCA are compatible with those generated by SPECT. {dagger}P < .01.


Figure 3
View larger version (13K):
[in this window]
[in a new window]

 
Fig 3. The CBF ratios of the affected MCA territory to the contralateral corresponding area with different algorithms and different locations of AIFs. When comparing the CBF ratios with SPECT, we observed that the CBF ratios were underestimated in many patients on CTP with sSVD and bMTF but not with bSVD, regardless of the location (affected or unaffected side) of the AIF on the MCA.