AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Heiserman, J. E.
Right arrow Articles by Nederkoorn, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Heiserman, J. E.
Right arrow Articles by Nederkoorn, P. J.

Letter

Flow Voids and Carotid MR Angiography

Joseph E. Heiserman, PhD, MD, Director of MRIa

a Barrow Neurological Institute,
Phoenix, Arizona

I read with interest the recent article by Nederkoorn and coworkers (1) regarding the occurrence of flow voids in 3D time-of-flight MR angiography (TOF-MRA) of the carotid bifurcation, although I was disappointed that they had not discovered a smaller series analyzing 2D TOF-MRA published by our group (2). In fact, the lower limit of percent stenosis associated with a flow void is similar between the two studies, probably primarily due to the relatively long echo time (TE = 6.9 ms) used in Nederkoorn’s 3D-TOF series. It is important to note that flow voids would be even more likely to represent greater than 70% diameter stenosis with a shorter TE, as is commonly employed by many practitioners for this purpose. In 10 of the 14 arteries in which flow voids were observed at less than 70% stenosis as determined by digital substraction angiography (DSA), the authors note that Doppler sonography suggested a more severe stenosis. A trend toward poor DSA image quality with increasing stenosis is suggested as a cause. Since only two or three projections were obtained of each artery at DSA, another possible cause would be underestimation of true stenosis by DSA due to lack of the optimal projection.

References

  1. Nedekoorn PJ, van der Graaf Y, Eikelboom BC, van der Lugt A, Bartels LW, Mali WPTM. Time-of-flight MR angiography of carotid artery stenosis: Does a flow void represent severe stenosis? AJNR2002; 23 :1779 –1784[Abstract/Free Full Text]

  2. Heiserman JE, Zabramski JM, Drayer BP, Keller PJ. Clinical significance of the flow gap in carotid magnetic resonance angiography. J Neurosurg1996; 85 :384 –387[Medline]


 
Willem P.T.M. Malib and Paul J. Nederkoornb

b Department of Radiology
University Hospital
Utrech, the Netherlands

Reply

We agree with the clinical important findings described by Heiserman et al (1). Their study, however, focused on 2D-TOF MRA, where we describe the results of 3D-TOF MRA. We have only used 2D-TOF MRA to confirm flow void artifacts found on the three-dimensional images. In our opinion maximal-intensity-projections of 3D-TOF MRA are actually used in clinical practice to determine the degree of stenosis and therefore flow voids often are recognized with this technique. However, their conclusions certainly are in line with our findings and we apologize for not having cited their article. We agree with their suggestion that DSA in two or three projections might underestimate stenosis. Moreover, we recently studied the same hypothesis (2) and found it confirmed.

References

  1. Heiserman JB, Zabrarnski JM, Drayer BP, Keller PJ. Clinical significance of the flow gap in carotid magnetic resonance angiography. J Neurosurg1996; 85 :384 –387[Medline]

  2. Nederkoorn PJ, Elgersma OE, Mali WP, Eikelboom BC, Kappelle LJ, van der Graaf Y. Overestimation of carotid artery stenosis with magnetic resonance angiography compared with digital subtraction angiography. J Vasc Surg2002; 36 :806 –13[Medline]




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
F. Runck, R.P. Steiner, W.A. Bautz, and M.M. Lell
MR Imaging: Influence of Imaging Technique and Postprocessing on Measurement of Internal Carotid Artery Stenosis
AJNR Am. J. Neuroradiol., October 1, 2008; 29(9): 1736 - 1742.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Lell, C. Fellner, U. Baum, T. Hothorn, R. Steiner, W. Lang, W. Bautz, and F.A. Fellner
Evaluation of Carotid Artery Stenosis with Multisection CT and MR Imaging: Influence of Imaging Modality and Postprocessing
AJNR Am. J. Neuroradiol., January 1, 2007; 28(1): 104 - 110.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Heiserman, J. E.
Right arrow Articles by Nederkoorn, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Heiserman, J. E.
Right arrow Articles by Nederkoorn, P. J.