AJDRAJNR - American Journal of Neuroradiology

Published ahead of print on October 10, 2007
doi: 10.3174/ajnr.A0741

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
ajnr.A0741v1
29/1/134    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Romijn, M.
Right arrow Articles by Majoie, C.B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Romijn, M.
Right arrow Articles by Majoie, C.B.

BRAIN

Diagnostic Accuracy of CT Angiography with Matched Mask Bone Elimination for Detection of Intracranial Aneurysms: Comparison with Digital Subtraction Angiography and 3D Rotational Angiography

M. Romijna, H.A.F. Gratama van Andelb, M.A. van Walderveena, M.E. Sprengersa, J.C. van Rijna, W.J. van Rooijc, H.W. Venemaa,b, C.A. Grimbergenb, G.J. den Heetena and C.B. Majoiea

a Department of Radiology, Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
b Department of Medical Physics, Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
c Department of Radiology, St. Elisabeth Ziekenhuis, Tilburg, the Netherlands

Please address correspondence to C.B. Majoie, MD, PhD, Department of Radiology, Room G1-223.2, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, the Netherlands; e-mail: c.b.majoie{at}amc.uva.nl

BACKGROUND AND PURPOSE: Our aim was to determine the diagnostic accuracy of multisection CT angiography combined with matched mask bone elimination (CTA-MMBE) for detection of intracranial aneurysms compared with digital subtraction angiography (DSA) and 3D rotational angiography (3DRA).

MATERIALS AND METHODS: Between January 2004 and February 2006, 108 patients who presented with clinically suspected subarachnoid hemorrhage underwent both CTA-MMBE and DSA for diagnosis of an intracranial aneurysm. Two neuroradiologists, independently, evaluated 27 predefined vessel locations in the CTA-MMBE images for the presence of an aneurysm. After consensus, diagnostic accuracy of CTA was calculated per predefined location and per patient. Interobserver agreement was calculated with {kappa} statistics.

RESULTS: In 88 patients (81%), 117 aneurysms (82 ruptured, 35 unruptured) were present on DSA. CTA-MMBE detected all ruptured aneurysms except 1. Overall specificity, sensitivity, positive predictive value, and negative predictive value of CTA-MMBE were 0.99, 0.90, 0.98, and 0.95 per patient and 0.91, 1.00, 0.97, and 0.99 per location, respectively. Sensitivity was 0.99 for aneurysms ≥3 mm and 0.38 for aneurysms <3 mm. Interobserver agreement for aneurysm detection was excellent ({kappa} value of 0.92 per location and 0.80 per patient).

CONCLUSION: CTA-MMBE is accurate in detecting intracranial aneurysms in any projection without overprojecting bone. CTA-MMBE has limited sensitivity in detecting very small aneurysms. Our data suggest that DSA and 3DRA can be limited to the vessel harboring the ruptured aneurysm before endovascular treatment, after detection of a ruptured aneurysm with CTA.




This article has been cited by other articles:


Home page
RadiologyHome page
Q. Li, F. Lv, Y. Li, T. Luo, K. Li, and P. Xie
Evaluation of 64-Section CT Angiography for Detection and Treatment Planning of Intracranial Aneurysms by Using DSA and Surgical Findings
Radiology, September 1, 2009; 252(3): 808 - 815.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. J. Kaufmann and D. F. Kallmes
Diagnostic Cerebral Angiography: Archaic and Complication-Prone or Here to Stay for Another 80 Years?
Am. J. Roentgenol., June 1, 2008; 190(6): 1435 - 1437.
[Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
W.J. van Rooij, J.P.P. Peluso, M. Sluzewski, and G.N. Beute
Additional Value of 3D Rotational Angiography in Angiographically Negative Aneurysmal Subarachnoid Hemorrhage: How Negative Is Negative?
AJNR Am. J. Neuroradiol., May 1, 2008; 29(5): 962 - 966.
[Abstract] [Full Text] [PDF]