AJDRAJNR - American Journal of Neuroradiology

Published ahead of print on April 16, 2008
doi: 10.3174/ajnr.A1089

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
ajnr.A1089v1
29/7/1344    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Google Scholar
Right arrow Articles by Everton, K.L.
Right arrow Articles by Harnsberger, H.R.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Everton, K.L.
Right arrow Articles by Harnsberger, H.R.

HEAD & NECK

The Oculomotor Cistern: Anatomy and High-Resolution Imaging

K.L. Evertona, U.A. Rassnera, A.G. Osborna and H.R. Harnsbergera

a From the Department of Radiology, University of Utah, Salt Lake City, Utah

Please address correspondence to Anne G. Osborn, MD, Department of Radiology, College of Medicine, 1A71 University Hospital, Salt Lake City, Utah 84132; e-mail: Anne.Osborn{at}hsc.utah.edu

BACKGROUND AND PURPOSE: The oculomotor cistern (OMC) is a small CSF-filled dural cuff that invaginates into the cavernous sinus, surrounding the third cranial nerve (CNIII). It is used by neurosurgeons to mobilize CNIII during cavernous sinus surgery. In this article, we present the OMC imaging spectrum as delineated on 1.5T and 3T MR images and demonstrate its involvement in cavernous sinus pathology.

MATERIALS AND METHODS: We examined 78 high-resolution screening MR images of the internal auditory canals (IAC) obtained for sensorineural hearing loss. Cistern length and diameter were measured. Fifty randomly selected whole-brain MR images were evaluated to determine how often the OMC can be visualized on routine scans. Three volunteers underwent dedicated noncontrast high-resolution MR imaging for optimal OMC visualization.

RESULTS: One or both OMCs were visualized on 75% of IAC screening studies. The right cistern length averaged 4.2 ± 3.2 mm; the opening diameter (the porus) averaged 2.2 ± 0.8 mm. The maximal length observed was 13.1 mm. The left cistern length averaged 3.0 ± 1.7 mm; the porus diameter averaged 2.1 ±1.0 mm, with a maximal length of 5.9 mm. The OMC was visualized on 64% of routine axial T2-weighted brain scans.

CONCLUSION: The OMC is an important neuroradiologic and surgical landmark, which can be routinely identified on dedicated thin-section high-resolution MR images. It can also be identified on nearly two thirds of standard whole-brain MR images.