AJDRAJNR - American Journal of Neuroradiology

Publication Preview: Published February 13, 2008

American Journal of Neuroradiology 2008;29:1017.

This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
ajnr.A0955v1
29/5/1017    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yeom, J.S.
Right arrow Articles by Riew, K.D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yeom, J.S.
Right arrow Articles by Riew, K.D.

SPINE

Value of Diagnostic Lumbar Selective Nerve Root Block: A Prospective Controlled Study

J.S. Yeom, J.W. Lee, K.-W. Park, B.-S. Chang, C.-K. Lee, J.M. Buchowski and K.D. Riew

From the Departments of Orthopaedic Surgery (J.S.Y., K.-W.P., B.-S.C., C.-K.L.) and Radiology (J.W.L.), Seoul National University College of Medicine, Seoul, Republic of Korea; and Department of Orthopaedic Surgery (J.M.B., K.D.R.), Washington University, St. Louis, Mo.

Please address correspondence to Bong-Soon Chang, M.D., Assistant Professor, Department of Orthopaedic Surgery, Seoul National University School of Medicine, 28 Yeonkeon-dong, Chongro-gu, Seoul, 110-744, Republic of Korea; e-mail: bschang{at}snu.ac.kr

BACKGROUND AND PURPOSE: Although diagnostic lumbar selective nerve root blocks are often used to confirm the pain-generating nerve root level, the reported accuracy of these blocks has been variable and their usefulness is controversial. The purpose of this study was to evaluate the accuracy of diagnostic lumbar selective nerve root blocks to analyze potential causes of false results in a prospective, controlled, single-blinded manner.

Materials and METHODS: A total of 105 block anesthetics were performed under fluoroscopic guidance in 47 consecutive patients with pure radiculopathy from a single confirmed level: 47 blocks were performed at the symptomatic level, and 58 were performed at the adjacent asymptomatic "control" level. Contrast and local anesthetics were injected, and spot radiographs were taken in all cases. We calculated the diagnostic value of the block anesthetics using concordance with the injected level. We analyzed the potential causes of false results using spot radiographs.

RESULTS: On the basis of a definition of a positive block as 70% pain relief, determined by receiver-operator characteristic (ROC) analysis, diagnostic lumbar selective nerve root block anesthetics had a sensitivity of 57%, a specificity of 86%, an accuracy of 73%, a positive predictive value of 77%, and a negative predictive value of 71%. False-negatives were due to the following causes identifiable on spot radiographs: insufficient infiltration, insufficient passage of the injectate, and intraepineural injections. On the other hand, false-positives resulted from overflow of the injectate from the injected asymptomatic level into either the epidural space or symptomatic level.

CONCLUSION: The accuracy of diagnostic lumbar selective nerve root blocks is only moderate. To improve the accuracy, great care should be taken to avoid inadequate blocks and overflow, and to precisely interpret spot radiographs.