AJDRAJNR - American Journal of Neuroradiology

Publication Preview: Published May 1, 2008

American Journal of Neuroradiology 2008;29:1324.

This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
ajnr.A1105v1
29/7/1324    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Weon, Y.C.
Right arrow Articles by Kim, S.Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Weon, Y.C.
Right arrow Articles by Kim, S.Y.

BRAIN

Optimal Diffusion-Weighted Imaging Protocol for Lesion Detection in Transient Global Amnesia

Y.C. Weon, J.H. Kim, J.S. Lee and S.Y. Kim

From the Departments of Radiology (Y.C.W., J.H.K.) and Neurology (J.S.L., S.Y.K.), Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seoul, Korea.

Please address correspondence to Jae Hyoung Kim, MD, Department of Radiology, Seoul National University Bundang Hospital, 300 Gumi-dong, Bundang-gu, Seongnam-si, 463-707, Korea; e-mail: jaehkim{at}snu.ac.kr

BACKGROUND AND PURPOSE: Diffusion-weighted imaging (DWI) can depict small punctate hyperintense lesions in the hippocampus in transient global amnesia (TGA). The purpose of this study was to find an optimal DWI protocol for lesion detection in TGA by investigating various imaging parameters and imaging timing after symptom onset.

MATERIALS AND METHODS: Sixteen patients with TGA diagnosed during 14 months underwent DWI within 24 hours and again at follow-up 3 days after onset. Each DWI session included 4 different sequences using different b-values (seconds per square millimeter) and section thicknesses (millimeter): 1000/5, 1000/3, 2000/3, and 3000/3. The presence or absence of hyperintense lesions on the 8 DWIs was determined visually, and the number of lesions detected was compared.

RESULTS: Thirteen of the 16 patients (81%) had either single or multiple punctate hyperintense lesions, totaling 24 lesions, and the remaining 3 patients had no lesions. All lesions detected were in the hippocampus except 1. The number of lesions detected on initial DWIs at a b-value/section thickness of 1000/5, 1000/3, 2000/3, and 3000/3 was 3, 9, 13, and 13, respectively, whereas that of follow-up DWIs was 17, 22, 24, and 24, respectively.

CONCLUSION: On the basis of these preliminary results, the highest lesion detection was achieved for DWI with b = 2000/3 mm or b = 3000/3 mm at 3 days postonset. When no lesion is detected by DWI within 24 hours after onset, follow-up DWI is recommended several days later.