Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Other Publications
    • ajnr

User menu

  • Subscribe
  • Alerts
  • Log in
  • Log out

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in
  • Log out

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
Abstract

Fast spin-echo and fast fluid-attenuated inversion-recovery versus conventional spin-echo sequences for MR quantification of multiple sclerosis lesions.

S Bastianello, A Bozzao, A Paolillo, E Giugni, C Gasperini, T Koudriavtseva, E Millefiorini, M A Horsfield, C Colonnese, D Toni, M Fiorelli, C Pozzilli and L Bozzao
American Journal of Neuroradiology April 1997, 18 (4) 699-704;
S Bastianello
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A Bozzao
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A Paolillo
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
E Giugni
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C Gasperini
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T Koudriavtseva
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
E Millefiorini
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M A Horsfield
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C Colonnese
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
D Toni
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M Fiorelli
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C Pozzilli
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
L Bozzao
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Abstract

PURPOSE To compare fast spin-echo (FSE) and fast fluid-attenuated inversion recovery (FLAIR) sequences with conventional spin-echo (CSE) MR imaging in the quantification of the number and volume of multiple sclerosis lesions.

METHODS In 30 patients with relapsing-remitting multiple sclerosis, we calculated the total number and volume of lesions detected with each of the three sequences using a semiautomated program.

RESULTS On CSE sequences, we calculated a total of 2,583 lesions with a global volume of 836.3 cm3. With FSE sequences, we observed a 16% relative reduction in the number of lesions detected and a 25% relative reduction in global volume as compared with CSE. With fast FLAIR sequences, we detected a significantly lower number and volume of infratentorial lesions, whereas at the cortical/subcortical level the lesions were both more numerous and bulkier than on CSE sequences. Finally, we observed a higher lesion/white matter contrast, a significant reduction in time required for the quantification of lesion load, and a very low interobserver variability in favor of fast FLAIR sequences.

CONCLUSION Despite its limitations in the detection of infratentorial lesions, the fast FLAIR sequence in conjunction with a semiautomated quantification program provides a reliable means to evaluate the total lesion burden in patients with MS.

  • Copyright © American Society of Neuroradiology
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology
Vol. 18, Issue 4
1 Apr 1997
  • Table of Contents
  • Index by author
Advertisement
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Fast spin-echo and fast fluid-attenuated inversion-recovery versus conventional spin-echo sequences for MR quantification of multiple sclerosis lesions.
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Fast spin-echo and fast fluid-attenuated inversion-recovery versus conventional spin-echo sequences for MR quantification of multiple sclerosis lesions.
S Bastianello, A Bozzao, A Paolillo, E Giugni, C Gasperini, T Koudriavtseva, E Millefiorini, M A Horsfield, C Colonnese, D Toni, M Fiorelli, C Pozzilli, L Bozzao
American Journal of Neuroradiology Apr 1997, 18 (4) 699-704;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Fast spin-echo and fast fluid-attenuated inversion-recovery versus conventional spin-echo sequences for MR quantification of multiple sclerosis lesions.
S Bastianello, A Bozzao, A Paolillo, E Giugni, C Gasperini, T Koudriavtseva, E Millefiorini, M A Horsfield, C Colonnese, D Toni, M Fiorelli, C Pozzilli, L Bozzao
American Journal of Neuroradiology Apr 1997, 18 (4) 699-704;
del.icio.us logo Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Prehypertensive Blood Pressures and Regional Cerebral Blood Flow Independently Relate to Cognitive Performance in Midlife
  • FLAIR2: A Combination of FLAIR and T2 for Improved MS Lesion Detection
  • Brain Function, Cognition, and the Blood Pressure Response to Pharmacological Treatment
  • Brain Imaging Findings Predict Blood Pressure Response to Pharmacological Treatment
  • Reduced cerebral blood flow response and compensation among patients with untreated hypertension
  • Exclusion of brain lesions: is MR contrast medium required after a negative fluid-attenuated inversion recovery sequence?
  • A Comparison of MR Imaging with Fast-FLAIR, HASTE-FLAIR, and EPI-FLAIR Sequences in the Assessment of Patients with Multiple Sclerosis
  • Memory Dysfunction in Multiple Sclerosis Corresponds to Juxtacortical Lesion Load on Fast Fluid-Attenuated Inversion-Recovery MR Images
  • Multisequence MRI in clinically isolated syndromes and the early development of MS
  • Relevance of Hypointense Lesions on Fast Fluid-Attenuated Inversion Recovery MR Images as a Marker of Disease Severity in Cases of Multiple
  • Interscanner Variation in Brain MR Lesion Load Measurements in Multiple Sclerosis Using Conventional Spin-Echo, Rapid Relaxation-Enhanced, and Fast-FLAIR Sequences
  • Precision and reliability for measurement of change in MRI lesion volume in multiple sclerosis: a comparison of two computer assisted techniques
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2021 Distinguished Reviewers
  • Press Releases

Resources

  • Evidence-Based Medicine Level Guide
  • How to Participate in a Tweet Chat
  • AJNR Podcast Archive
  • Ideas for Publicizing Your Research
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Share Your Art in Perspectives
  • Get Peer Review Credit from Publons
  • Moderate a Tweet Chat

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal
  • Position Statements

© 2022 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire