Abstract
MR angiography with ultrashort echo time in cerebral aneurysms treated with Guglielmi detachable coils.
F Gönner, O Heid, L Remonda, G Nicoli, R W Baumgartner, N Godoy and G Schroth
American Journal of Neuroradiology August 1998, 19 (7) 1324-1328;
F Gönner
Department of Neuroradiology, University of Berne, Switzerland.
O Heid
Department of Neuroradiology, University of Berne, Switzerland.
L Remonda
Department of Neuroradiology, University of Berne, Switzerland.
G Nicoli
Department of Neuroradiology, University of Berne, Switzerland.
R W Baumgartner
Department of Neuroradiology, University of Berne, Switzerland.
N Godoy
Department of Neuroradiology, University of Berne, Switzerland.
G Schroth
Department of Neuroradiology, University of Berne, Switzerland.

Abstract
We evaluated a time-of-flight three-dimensional MR angiographic sequence with an ultrashort echo time for its ability to characterize the perfusional state of cerebral aneurysms that had been treated with Guglielmi detachable coils and to depict adjacent cerebral arteries. The results were compared with findings at conventional MR angiography and digital subtraction angiography. Adjacent vessels were seen better in 36% of patients imaged with the new technique. Both MR angiographic methods detected residual cerebral aneurysmal perfusion with a tendency to overestimate the patent portion of the aneurysm.
- Copyright © American Society of Neuroradiology
In this issue
Advertisement
MR angiography with ultrashort echo time in cerebral aneurysms treated with Guglielmi detachable coils.
F Gönner, O Heid, L Remonda, G Nicoli, R W Baumgartner, N Godoy, G Schroth
American Journal of Neuroradiology Aug 1998, 19 (7) 1324-1328;
Jump to section
Related Articles
- No related articles found.
Cited By...
- MRA versus DSA for the follow-up imaging of intracranial aneurysms treated using endovascular techniques: a meta-analysis
- Pointwise Encoding Time Reduction with Radial Acquisition with Subtraction-Based MRA during the Follow-Up of Stent-Assisted Coil Embolization of Anterior Circulation Aneurysms
- Usefulness of Non-Contrast-Enhanced MR Angiography Using a Silent Scan for Follow-Up after Y-Configuration Stent-Assisted Coil Embolization for Basilar Tip Aneurysms
- Assessing Blood Flow in an Intracranial Stent: A Feasibility Study of MR Angiography Using a Silent Scan after Stent-Assisted Coil Embolization for Anterior Circulation Aneurysms
- MRA Versus DSA for Follow-Up of Coiled Intracranial Aneurysms: A Meta-Analysis
- In Vitro and In Vivo Imaging Characteristics Assessment of Polymeric Coils Compared with Standard Platinum Coils for the Treatment of Intracranial Aneurysms
- Outcomes of Endovascular Treatments of Aneurysms: Observer Variability and Implications for Interpreting Case Series and Planning Randomized Trials
- 3D Computerized Occlusion Rating of Embolized Experimental Aneurysms Using Noninvasive 1.5T MR Imaging
- Temporal Evolution of Susceptibility Artifacts from Coiled Aneurysms on MR Angiography: An In Vivo Canine Study
- A Prospective Trial of 3T and 1.5T Time-of-Flight and Contrast-Enhanced MR Angiography in the Follow-Up of Coiled Intracranial Aneurysms
- MR Angiographic Follow-Up of Intracranial Aneurysms Treated with Detachable Coils: Evaluation of a Blood-Pool Contrast Medium
- Follow-Up of Coiled Cerebral Aneurysms at 3T: Comparison of 3D Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography
- Noninvasive Imaging of Treated Cerebral Aneurysms, Part I: MR Angiographic Follow-Up of Coiled Aneurysms
- Follow-up of intracranial aneurysms selectively treated with coils: Prospective evaluation of contrast-enhanced MR angiography.
- Intracranial Aneurysms Treated With Guglielmi Detachable Coils: Imaging Follow-Up With Contrast-Enhanced MR Angiography
- Endovascular Treatment of Posterior Circulation Cerebral Aneurysms By Using Guglielmi Detachable Coils: A 10-Year Single-Center Experience with Special Regard to Technical Development
- MR Angiography at 3T versus Digital Subtraction Angiography in the Follow-up of Intracranial Aneurysms Treated with Detachable Coils
- MR Angiographic Evaluation of Platinum Coil Packs at 1.5T and 3T: An In Vitro Assessment of Artifact Production: Technical Note
- Intracranial Aneurysms Treated with Guglielmi Detachable Coils: Usefulness of 6-Month Imaging Follow-Up with Contrast-Enhanced MR Angiography
- Intracranial Aneurysms Treated with Guglielmi Detachable Coils: Is Contrast Material Necessary in the Follow-up with 3D Time-of-Flight MR Angiography?
- CT and MR Imaging Findings and Their Implications in the Follow-up of Patients with Intracranial Aneurysms Treated with Endosaccular Occlusion with Onyx
- Aneurysms of the Anterior Communicating Artery Treated with Guglielmi Detachable Coils: Follow-Up with Contrast-Enhanced MR Angiography
- Utility of CT Angiography and MR Angiography for the Follow-up of Experimental Aneurysms Treated with Stents or Guglielmi Detachable Coils
- Three-dimensional Time-of-Flight MR Angiography in the Evaluation of Intracranial Aneurysms Treated with Guglielmi Detachable Coils
- INTERVENTIONAL NEURORADIOLOGY
- MR Angiography with Three-Dimensional Time-of-Flight and Targeted Maximum-Intensity-Projection Reconstructions in the Follow-up of Intracranial Aneurysms Embolized with Guglielmi Detachable Coils
This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.
Similar Articles
Advertisement