Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Other Publications
    • ajnr

User menu

  • Subscribe
  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
Research ArticleSPINE

Percutaneous Vertebroplasty: A Special Syringe for Cement Injection

Imad Al-Assir, Antonio Perez-Higueras, Jose Florensa, Alberto Muñoz and Emilio Cuesta
American Journal of Neuroradiology January 2000, 21 (1) 159-161;
Imad Al-Assir
aFrom the Department of Neuroradiology (I.A.-A., A.P.-H., J.F., E.C.), Fundación Jiménez Díaz, and the Department of Radiology (A.M.), Section of Neuroradiology, Hospital Universitario, Madrid, Spain.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Antonio Perez-Higueras
aFrom the Department of Neuroradiology (I.A.-A., A.P.-H., J.F., E.C.), Fundación Jiménez Díaz, and the Department of Radiology (A.M.), Section of Neuroradiology, Hospital Universitario, Madrid, Spain.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jose Florensa
aFrom the Department of Neuroradiology (I.A.-A., A.P.-H., J.F., E.C.), Fundación Jiménez Díaz, and the Department of Radiology (A.M.), Section of Neuroradiology, Hospital Universitario, Madrid, Spain.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Alberto Muñoz
aFrom the Department of Neuroradiology (I.A.-A., A.P.-H., J.F., E.C.), Fundación Jiménez Díaz, and the Department of Radiology (A.M.), Section of Neuroradiology, Hospital Universitario, Madrid, Spain.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Emilio Cuesta
aFrom the Department of Neuroradiology (I.A.-A., A.P.-H., J.F., E.C.), Fundación Jiménez Díaz, and the Department of Radiology (A.M.), Section of Neuroradiology, Hospital Universitario, Madrid, Spain.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

Article Figures & Data

Figures

  • Figure1
    • Download figure
    • Open in new tab
    • Download powerpoint

    fig 1. Material used in vertebroplasty. 1, special screw system syringe (A, handle; B, luer-lock end; C, lateral port; D, screw plunger); 2, high-pressure plastic tubing; 3, 10-mL syringe; 4, 14-gauge needle; 5, short stylet; 6, long stylet; 7, container in which to mix cement; 8, spoon

  • Figure2
    • Download figure
    • Open in new tab
    • Download powerpoint

    fig 2. Special screw system syringe connected to the 10-mL syringe.

    A, Before loading, the cement within the conventional syringe that is connected to the lateral port (thin arrow) can be seen. Notice the screw system plunger (thick arrow).

    B, After loading, the cement within the special screw system syringe (asterisks), can be seen. The empty conventional syringe is still placed in the lateral port.

  • Figure3
    • Download figure
    • Open in new tab
    • Download powerpoint

    fig 3. Plastic tubing (thin arrow) and needle (crossed arrow) are connected to the syringe. As the screw plunger (thick arrow) is turned, the cement is advanced into the plastic tubing and then into the needle. The lateral port (short arrow) is excluded from the syringe chamber as the plunger advances. One hand holds the syringe by the handle, and the other turns the screw plunger

PreviousNext
Back to top

In this issue

American Journal of Neuroradiology
Vol. 21, Issue 1
1 Jan 2000
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Percutaneous Vertebroplasty: A Special Syringe for Cement Injection
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Percutaneous Vertebroplasty: A Special Syringe for Cement Injection
Imad Al-Assir, Antonio Perez-Higueras, Jose Florensa, Alberto Muñoz, Emilio Cuesta
American Journal of Neuroradiology Jan 2000, 21 (1) 159-161;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Percutaneous Vertebroplasty: A Special Syringe for Cement Injection
Imad Al-Assir, Antonio Perez-Higueras, Jose Florensa, Alberto Muñoz, Emilio Cuesta
American Journal of Neuroradiology Jan 2000, 21 (1) 159-161;
del.icio.us logo Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Technique
    • Discussion
    • Conclusion
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Radiation Dose to the Operator during Vertebroplasty: Prospective Comparison of the Use of 1-cc Syringes versus an Injection Device
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Surgical Ligation of Spinal CSF-Venous Fistulas after Transvenous Embolization in Patients with Spontaneous Intracranial Hypotension
  • Spontaneous Spinal CSF Leaks Stratified by Age, Body Mass Index, and Spinal Level
  • MRI Findings after Recent Image-Guided Lumbar Puncture: The Rate of Dural Enhancement and Subdural Collections
Show more SPINE

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2021 Distinguished Reviewers
  • Press Releases

Resources

  • Evidence-Based Medicine Level Guide
  • How to Participate in a Tweet Chat
  • AJNR Podcast Archive
  • Ideas for Publicizing Your Research
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Share Your Art in Perspectives
  • Get Peer Review Credit from Publons
  • Moderate a Tweet Chat

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal
  • Position Statements

© 2022 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire