Research ArticleEDITORIAL
Diffusion-weighted Imaging as a Surrogate Marker for Stroke as a Complication of Cerebrovascular Procedures and Devices
Colin P. Derdeyn
American Journal of Neuroradiology August 2001, 22 (7) 1234-1235;
References
- ↵Ginsberg LE, Stump DA, King JC, Deal DD, Moody DM. Air embolus risk with glass versus plastic syringes: in vitro study and implications for neuroangiography. Radiology 1994;191:813-816
- ↵Moody DM, Bell MA, Challa VA, Johnston WE, Prough DS. Brain microemboli during cardiac surgery or aortography. Ann Neurol 1990;28:477-486
- Theron JG, Payelle GG, Coskun , et al. Carotid artery stenosis: treatment with balloon angioplasty and stent placement. Radiology 1996;201:607-636
- ↵Klotzsch C, Nahser HC, Henkes H, Kuhne D, Berlit P. Detection of microemboli distal to cerebral aneurysms before and after therapeutic embolization. AJNR Am J Neuroradiol 1998;19:1315-1318
- ↵Rordorf G, Bellon RJ, Budzik RF Jr, et al. Silent thromboembolic events associated with the treatment of unruptured cerebral aneurysms by use of Guglielmi detachable coils: prospective study applying diffusion-weighted imaging. AJNR Am J Neuroradiol 2001;22:5-10
- ↵Bendszus M, Koltzenburg M, Buger R, Warmuth-Metz M, Hofmann E, Solymosi L. Silent embolism in diagnostic cerebral angiography and neurointernventional procedures: a prospective study. Lancet 1999;354:1594-1597
- Diegler A, Hirsch R, Schneider F, Schilling LO, Falk V, Rauch T, Mohr FW. Neuromonitoring and neurocognitive outcome in off-pump versus conventional coronary bypass operation. Ann Thorac Surg 2000;69:1162-1166
In this issue
Advertisement
Diffusion-weighted Imaging as a Surrogate Marker for Stroke as a Complication of Cerebrovascular Procedures and Devices
Colin P. Derdeyn
American Journal of Neuroradiology Aug 2001, 22 (7) 1234-1235;
Jump to section
Related Articles
- No related articles found.
Cited By...
- Association of Iatrogenic Infarcts With Clinical and Cognitive Outcomes in the Evaluating Neuroprotection in Aneurysm Coiling Therapy Trial
- Embolic Protection Devices in Transcatheter Aortic Valve Replacement
- Microembolism and Catheter Ablation II: Effects of Cerebral Microemboli Injection in a Canine Model
- New Ischemic Brain Lesions on Diffusion-Weighted MRI after Carotid Artery Stenting with Filter Protection: Frequency and Relationship with Plaque Morphology
- Ischemic Cerebrovascular Complications of Cardiac Procedures
- Silent Cerebral Ischemia Detected With Diffusion-Weighted Imaging in Patients Treated With Protected and Unprotected Carotid Artery Stenting
This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.
More in this TOC Section
Similar Articles