Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Other Publications
    • ajnr

User menu

  • Subscribe
  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
Research ArticleBRAIN

Multivoxel 3D Proton Spectroscopy in the Brain at 1.5 Versus 3.0 T: Signal-to-Noise Ratio and Resolution Comparison

Oded Gonen, Stephan Gruber, Belinda S. Y. Li, Vladimir Mlynárik and Ewald Moser
American Journal of Neuroradiology October 2001, 22 (9) 1727-1731;
Oded Gonen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Stephan Gruber
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Belinda S. Y. Li
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Vladimir Mlynárik
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ewald Moser
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

References

  1. ↵
    Thulborn KR. Why neuroradiologists should consider very-high field magnets for clinical applications of functional magnetic resonance imaging. Top Magn Reson Imag 1999;10:1-2
    CrossRefPubMed
  2. ↵
    Hoult DI, Lauterbur PC. The sensitivity of the zeugmatographic experiment involving human samples. J Magn Reson 1979;34:425-433
    CrossRefWeb of Science
  3. ↵
    Edelstein WA, Glover GH, Hardy CJ, Edington RW. The intrinsic signal-to-noise ratio in NMR imaging. Magn Reson Med 1986;3:604-618
    PubMedWeb of Science
  4. Ocali O, Atalar E. Ultimate intrinsic signal-to-noise ratio in MRI. Magn Reson Med 1998;39:462-473
    PubMed
  5. Gruetter R, Weisdorf SA, Rajanayagan V, et al. Resolution improvements in in vivo 1H NMR spectra with increased magnetic field strength. J Magn Reson 1998;135:260-264
    CrossRefPubMed
  6. Jezzard JP, Duewell S, Balaban RS. MR relaxation times in human brain: measurements at 4 T. Radiology 1996;199:773-779
    PubMedWeb of Science
  7. ↵
    Hu J, Javaid T, Arias-Mendoza F, Liu Z, McNamara R, Brown TR. A fast, reliable automatic shimming procedure using 1H chemical shift imaging spectroscopy. J Magn Reson Ser B 1995;108:213-219
    CrossRefPubMed
  8. ↵
    Haase A, Frahm J, Hänicke W, Matthaei D. 1H NMR chemical shift selective (CHESS) imaging. Phys Med Biol 1985;30:341-344
    CrossRefPubMedWeb of Science
  9. Star-Lack J, Nelson SJ, Kurhanewicz J, Huang LR, Vigneron DB. Improved water and lipid suppression for 3D PRESS CSI using RF band selective inversion with gradient dephasing (BASING). Magn Reson Med 1997;38:311-321
    PubMed
  10. ↵
    Gruetter R. Automatic localized in vivo adjustment of all first and second order shim coils. Magn Reson Med 1993;29:804-811
    CrossRefPubMedWeb of Science
  11. ↵
    Gonen O, Arias-Mendoza F, Goelman G. 3D localized In Vivo 1H spectroscopy of human brain using a hybrid of 1D-Hadamard with 2D-chemical shift imaging. Magn Reson Med 1997;37:644-650
    CrossRefPubMed
  12. Gonen O, Wang Z-J, Molloy PT, Zimmerman RA. A Hadamard/chemical shift imaging hybrid for pediatric brain 3D multivoxel proton NMR spectroscopy: application to neurofibromatosis type I disorder. AJNR Am J Neuroradiol 1999;20:1333-1341
    Abstract/FREE Full Text
  13. ↵
    Bottomley PA. Spatial localization in NMR spectroscopy in vivo. Ann NY Acad Sci 1987;508:333-348
    CrossRefPubMedWeb of Science
  14. ↵
    Kreis R, Ernst T, Ross BD. Absolute concentrations of water and metabolites in the human brain. II. Metabolite concentrations. J Magn Reson 1993;102:9-19
    CrossRefWeb of Science
  15. Barker PB, Blackband SJ, Chatham JC, Mathews VP, Bryan RN. Quantitation of proton NMR spectra of the human brain using tissue water as an internal concentration reference. NMR Biomed 1993;6:89-94
    CrossRefPubMedWeb of Science
  16. Mlynárik V, Gruber S, Moser E. Proton relaxation times of metabolites in human brain tissue at 3 Tesla. MAGMA 2000;11:185
  17. Gonen O, Murdoch JB, Stoyanova R, Goelman G. 3D multivoxel proton spectroscopy of human brain using a hybrid of 8th-order Hadamard encoding with 2D-chemical shift imaging. Magn Reson Med 1998;39:34-40
    PubMed
  18. ↵
    Marion D, Ikura M, Bax A. Improved solvent suppression in one- and two-dimensional NMR spectra by convolution of time domain data. J Magn Reson 1989;84:425-430
    Web of Science
  19. ↵
    Duyn JH, Gillen J, Sobering G, van Zijl PCM, Moonen CTW. Multisection proton MR spectroscopic imaging of the brain. Radiology 1993;188:277-282
    PubMedWeb of Science
  20. ↵
    Ernst RR, Bodenhausen G, Wokaun A. Principles of Nuclear Magnetic Resonance in One and Two Dimensions. Oxford, England: Clarendon; 1987;152
  21. ↵
    Soher BJ, Young K, Govindaraju V, Maudsley AA. Automated spectral analysis III: application to in vivo proton MR spectroscopy and spectroscopic imaging. Magn Reson Med 1998;40:822-831
    PubMedWeb of Science
  22. Frahm J, Bruhn H, Gyngell ML, Merboldt KD, Hänicke W, Sauter R. Localized proton NMR spectroscopy in different regions of the human brain in vivo. Relaxation times and concentration of cerebral metabolites. Magn Reson Med 1989;11:47-63
    PubMedWeb of Science
  23. ↵
    Danielsen EA, Ross B. Magnetic Resonance Spectroscopy Diagnosis of Neurological Diseases. New York, NY: Marcel Dekker; 1999
  24. ↵
    Li S, Williams GD, Frisk TA, Arnold BW, Smith MB. A computer simulation of the static magnetic field distribution in the human head. Magn Reson Med 1995;34:268-275
    PubMedWeb of Science
  25. ↵
    Li S, Dardzinski BJ, Collins CM, Yang QX, Smith MB. Three-dimensional mapping of the static field inside the human head. Magn Reson Med 1996;36:705-714
    PubMed
  26. Gonen O, Grossman RI. The accuracy of whole brain N-acetylaspartate quantification. Magn Reson Imag 2000;18:1255-1258
    CrossRefPubMedWeb of Science
  27. ↵
    Hanson LG, Adalsteinsson E, Pfefferbaum A, Spielman DM. Optimal voxel size for measuring global gray and white matter proton metabolite concentrations using chemical shift imaging. Magn Reson Imag 2000;44:10-18
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 22 (9)
American Journal of Neuroradiology
Vol. 22, Issue 9
1 Oct 2001
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Multivoxel 3D Proton Spectroscopy in the Brain at 1.5 Versus 3.0 T: Signal-to-Noise Ratio and Resolution Comparison
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Multivoxel 3D Proton Spectroscopy in the Brain at 1.5 Versus 3.0 T: Signal-to-Noise Ratio and Resolution Comparison
Oded Gonen, Stephan Gruber, Belinda S. Y. Li, Vladimir Mlynárik, Ewald Moser
American Journal of Neuroradiology Oct 2001, 22 (9) 1727-1731;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Multivoxel 3D Proton Spectroscopy in the Brain at 1.5 Versus 3.0 T: Signal-to-Noise Ratio and Resolution Comparison
Oded Gonen, Stephan Gruber, Belinda S. Y. Li, Vladimir Mlynárik, Ewald Moser
American Journal of Neuroradiology Oct 2001, 22 (9) 1727-1731;
del.icio.us logo Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Methods
    • Results
    • Discussion
    • Conclusion
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Magnetic resonance spectroscopy of the brain
  • Reduced medial temporal lobe N-acetylaspartate in cognitively impaired but nondemented patients
  • NMR Spectroscopy and Pediatric Brain Tumors
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Fast Contrast-Enhanced 4D MRA and 4D Flow MRI Using Constrained Reconstruction (HYPRFlow): Potential Applications for Brain Arteriovenous Malformations
  • Multimodal CT Provides Improved Performance for Lacunar Infarct Detection
  • Optimal MRI Sequence for Identifying Occlusion Location in Acute Stroke: Which Value of Time-Resolved Contrast-Enhanced MRA?
Show more BRAIN

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2021 Distinguished Reviewers
  • Press Releases

Resources

  • Evidence-Based Medicine Level Guide
  • How to Participate in a Tweet Chat
  • AJNR Podcast Archive
  • Ideas for Publicizing Your Research
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Share Your Art in Perspectives
  • Get Peer Review Credit from Publons
  • Moderate a Tweet Chat

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal
  • Position Statements

© 2022 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire