Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Other Publications
    • ajnr

User menu

  • Subscribe
  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
Research ArticleINTERVENTIONAL

Evaluation of the Stability of Aneurysms after Embolization Using Detachable Coils: Correlation between Stability of Aneurysms and Embolized Volume of Aneurysms

Shinichi Tamatani, Yasushi Ito, Hiroshi Abe, Tetsuo Koike, Shigekazu Takeuchi and Ryuichi Tanaka
American Journal of Neuroradiology May 2002, 23 (5) 762-767;
Shinichi Tamatani
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yasushi Ito
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hiroshi Abe
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tetsuo Koike
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Shigekazu Takeuchi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ryuichi Tanaka
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

References

  1. ↵
    Bavinzski G, Killer M, Gruber A, Reinprecht A, Gross CE, Richling B. Treatment of basilar artery bifurcation aneurysms by using Guglielmi detachable coils: a 6-year experience. J Neurosurg 1999;90:843–852
    PubMedWeb of Science
  2. ↵
    Byrne J, Sohn MJ, Molyneux AJ. Five-year experience in using coil embolization for ruptured intracranial aneurysms: outcomes and incidence of late rebleeding. J Neurosurg 1999;90:656–663
    CrossRefPubMedWeb of Science
  3. ↵
    Cognard C, Pierot L, Boulin A, et al. Intracranial aneurysms: endovascular treatment with mechanical detachable spirals in 60 aneurysms. Radiology 1997;202:783–792
    PubMedWeb of Science
  4. ↵
    Cognard C, Weill A, Castaings L, Moret J. Intracranial berry aneurysms: angiographic and clinical results after endovascular treatment. Radiology 1998;206:499–510
    PubMedWeb of Science
  5. ↵
    Cognard C, Weill A, Spelle L, et al. Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils. Radiology 1999;212:348–356
    CrossRefPubMedWeb of Science
  6. Graves VB, Strother CM, Duf TA, Perl J. Early treatment of ruptured aneurysms with Guglielmi detachable coils: effect on subsequent bleeding. Neurosurgery 1995;37:640–648
    PubMedWeb of Science
  7. Guglielmi G, Viñnuela F, Duckwiler G, et al. Endovascular treatment of posterior circulation aneurysms by electrothrombosis using electrically detachable coils. J Neurosurg 1992;77:515–524
    PubMedWeb of Science
  8. ↵
    Hayakawa M, Murayama Y, Duckwiler GR, Gobin YP, Guglielmi G, Viñnuela F. Natural history of the neck remnant of a cerebral aneurysm treated with the Guglielmi detachable coil system. J Neurosurg 2000;93:561–568
    CrossRefPubMedWeb of Science
  9. ↵
    Malisch TW, Guglielmi G, Viñnuela F, et al. Intracranial aneurysms treated with the Guglielmi detachable coil: midterm clinical results in a consecutive series of 100 patients. J Neurosurg 1997;87:176–183
    CrossRefPubMedWeb of Science
  10. McDougall CG, Halbach VV, Dowd CF, Higashida RT, Larsen DW, Hieshima GB. Endovascular treatment of basilar tip aneurysms using electrolytically detachable coils. J Neurosurg 1996;84:393–399
    PubMedWeb of Science
  11. ↵
    Viñnuela F, Duckwiler G, Mawad M. Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 1997;86:475–482
    PubMedWeb of Science
  12. ↵
    Debrun GM, Aletich VA, Kehrli P, Misra M, Ausman JI, Charbel F. Selection of cerebral aneurysms for treatment using Guglielmi detachable coils: the preliminary university of Illinois at Chicago Experience. Neurosurgery 1998;43:1281–1297
    CrossRefPubMedWeb of Science
  13. Hodgson TJ, Carroll T, Jellinek DA. Subarachnoid hemorrhage due to late recurrence of a previously unruptured aneurysm after complete endovascular occlusion. AJNR Am J Neuroradiol 1998;19:1939–1941
    Abstract
  14. Makoui AS, Smith DA, Evans AJ, Cahill DW. Early aneurysm recurrence after technically satisfactory Guglielmi detachable coil therapy: is early surveillance needed? case report. J Neurosurg 2000;92:355–358
    CrossRefPubMed
  15. Manabe H, Fujita S, Hatayama T, Suzuki S, Yagihashi S. Rerupture of coil-embolized aneurysm during long-term observation: case report. J Neurosurg 1998;88:1096–1098
    PubMedWeb of Science
  16. ↵
    Mericle RA, Wakhloo AK, Lopes DK, Lanzino G, Guterman LR, Hopkins LN. Delayed aneurysm regrowth and recanalization after Guglielmi detachable coil treatment: case report. J Neurosurg 1998;89:142–145
    PubMed
  17. ↵
    Satoh K, Matsubara S, Hondoh H, Nagahiro S. Intracranial aneurysm embolization using Interlocking detachable coils. Intervent Neuroradiol 1997;3[suppl 2]:125–128
  18. ↵
    Guglielmi G, Viñnuela F, Dion J, Duckwiler G. Electrothrombosis of saccular aneurysms via endovascular approach: part 2: preliminary clinical experience. J Neurosurg 1991;75:8–14
    CrossRefPubMedWeb of Science
  19. ↵
    Fernandez Zubillaga A, Guglielmi G, Viñnuela F, Duckwiler GR. Endovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results. AJNR Am J Neuroradiol 1994;15:815–820
    Abstract/FREE Full Text
  20. ↵
    Graves VB, Strother CM, Partington CR, Rappe A. Flow dynamics of lateral carotid artery aneurysms and their effects on coils and balloons: an experimental study in dogs. AJNR Am J Neuroradiol 1992;13:189–196
    Abstract/FREE Full Text
  21. ↵
    Higashida RT, Smith W, Gress D, et al. Intravasculcar stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery: case report and review of the literature. J Neurosurg 1997;87:944–949
    CrossRefPubMedWeb of Science
  22. ↵
    Sekhon LH, Morgan MK, Sorby W, Grinnell V. Combined endovascular stent implantation and endovascular coil placement for the treatment of a wide-necked vertebral aneurysm: technical case report. Neurosurgery 1998;43:380–384
    CrossRefPubMedWeb of Science
  23. ↵
    Moret J, Cognard C, Weill A, Castaings L, Rey A. The “remodeling technique” in the treatment of wide neck intracranial aneurysms: angiographic results and clinical follow-up in 56 cases. Intervent Neuroradiol 1997;3:21–35
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 23 (5)
American Journal of Neuroradiology
Vol. 23, Issue 5
1 May 2002
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Evaluation of the Stability of Aneurysms after Embolization Using Detachable Coils: Correlation between Stability of Aneurysms and Embolized Volume of Aneurysms
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Evaluation of the Stability of Aneurysms after Embolization Using Detachable Coils: Correlation between Stability of Aneurysms and Embolized Volume of Aneurysms
Shinichi Tamatani, Yasushi Ito, Hiroshi Abe, Tetsuo Koike, Shigekazu Takeuchi, Ryuichi Tanaka
American Journal of Neuroradiology May 2002, 23 (5) 762-767;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Evaluation of the Stability of Aneurysms after Embolization Using Detachable Coils: Correlation between Stability of Aneurysms and Embolized Volume of Aneurysms
Shinichi Tamatani, Yasushi Ito, Hiroshi Abe, Tetsuo Koike, Shigekazu Takeuchi, Ryuichi Tanaka
American Journal of Neuroradiology May 2002, 23 (5) 762-767;
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Methods
    • Results
    • Discussion
    • Conclusion
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Long-Term Results and Follow-Up Examinations after Endovascular Embolization for Unruptured Cerebral Aneurysms
  • In vitro measurement of the permeability of endovascular coils deployed in cerebral aneurysms
  • Quantitative Analysis of Conebeam CT for Delineating Stents in Stent-Assisted Coil Embolization
  • Predisposing factors for recanalization of cerebral aneurysms after endovascular embolization: a multivariate study
  • Safety and effectiveness of large volume coils in the treatment of small aneurysms
  • Volume versus standard coils in the treatment of intracranial aneurysms
  • Influence of observers, threshold values, and measurement methods on volumetric analysis of cerebral aneurysms with three-dimensional rotational angiography
  • Balloon remodeling of complex anterior communicating artery aneurysms: technical considerations and complications
  • Mechanical properties and fibrin characteristics of endovascular coil-clot complexes: relevance to endovascular cerebral aneurysm repair paradigms
  • Predicting parent vessel patency and treatment durability: a proposed grading scheme for the immediate angiographic results following Onyx HD-500 embolization of intracranial aneurysms
  • Endovascular treatment of intracranial aneurysms with detachable coils: correlation between aneurysm volume, packing, and angiographic recurrence
  • Flow Diversion versus Traditional Endovascular Coiling Therapy: Design of the Prospective LARGE Aneurysm Randomized Trial
  • Validation and Initial Application of a Semiautomatic Aneurysm Measurement Software: A Tool for Assessing Volumetric Packing Attenuation
  • Analysis of Complications and Recurrences of Aneurysm Coiling with Special Emphasis on the Stent-Assisted Technique
  • Initial experience with Penumbra Coil 400 versus standard coils in embolization of cerebral aneurysms: a retrospective review
  • Initial experience with an extremely soft bare platinum coil, ED coil-10 Extra Soft, for endovascular treatment of cerebral aneurysms
  • Effect of Core Laboratory and Multiple-Reader Interpretation of Angiographic Images on Follow-Up Outcomes of Coiled Cerebral Aneurysms: A Systematic Review and Meta-Analysis
  • A carving method to determine an optimal working projection using three-dimensional volume rendering digital subtraction angiography in coil embolization of cerebral aneurysms
  • Complex shaped detachable platinum coil system for the treatment of cerebral aneurysms: The Codman Trufill DCS and Trufill DCS Orbit Detachable Coil System COMPLEX Registry final results
  • Analysis and quantification of endovascular coil distribution inside saccular aneurysms using histological images
  • AngioSuite: an accurate method to calculate aneurysm volumes and packing densities
  • Embolization of intracranial aneurysms with second-generation Matrix-2 detachable coils: mid-term and long-term results
  • How Do Coil Configuration and Packing Density Influence Intra-Aneurysmal Hemodynamics?
  • Matrix2 Coils in Embolization of Intracranial Aneurysms: 1-Year Outcome and Comparison with Bare Platinum Coil Group in a Single Institution
  • Stent-Assisted Coiling of Complex Middle Cerebral Artery Aneurysms: Initial and Midterm Results
  • Two-Year Follow-Up of Contrast Stasis within the Sac in Unruptured Aneurysm Coil Embolization: Progressive Thrombosis or Enlargement?
  • Relative cost comparison of embolic materials used for treatment of wide-necked intracranial aneurysms
  • Cerecyte versus Platinum Coils in the Treatment of Intracranial Aneurysms: Packing Attenuation and Clinical and Angiographic Midterm Results
  • Coiling of Intracranial Aneurysms: A Systematic Review on Initial Occlusion and Reopening and Retreatment Rates
  • Computerized Assessment of Angiographic Occlusion Rate and Coil Density in Embolized Human Cerebral Aneurysms
  • Retreatment of Previously Embolized Cerebral Aneurysms: The Risk of Further Coil Embolization Does Not Negate the Advantage of the Initial Embolization
  • Relationship Between Aneurysm Volume and Histologic Healing after Coil Embolization in Elastase-Induced Aneurysms: A Retrospective Study
  • Endovascular Treatment of Intracranial Aneurysms with Matrix Detachable Coils: Midterm Anatomic Follow-Up from a Prospective Multicenter Registry
  • Complex-Shaped Platinum Coils for Brain Aneurysms: Higher Packing Density, Improved Biomechanical Stability, and Midterm Angiographic Outcome
  • Retreatment of Ruptured Cerebral Aneurysms in Patients Randomized by Coiling or Clipping in the International Subarachnoid Aneurysm Trial (ISAT)
  • HydroCoil for Endovascular Aneurysm Occlusion (HEAL) Study: 3-6 Month Angiographic Follow-Up Results
  • Treatment of Cerebral Aneurysms with Hydrogel-Coated Platinum Coils (HydroCoil): Early Single-Center Experience
  • Embolization of Intracranial Aneurysms With Hydrogel-Coated Coils Versus Inert Platinum Coils: Effects on Packing Density, Coil Length and Quantity, Procedure Performance, Cost, Length of Hospital Stay, and Durability of Therapy
  • Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms.
  • Endosaccular Treatment of Intracranial Aneurysms Using Matrix Coils: Early Experience and Midterm Follow-Up
  • HydroCoil for Endovascular Aneurysm Occlusion (HEAL) Study: Periprocedural Results.
  • Volume Measurement of Intracranial Aneurysms from 3D Rotational Angiography: Improvement of Accuracy by Gradient Edge Detection
  • Matrix Detachable Coils for the Endovascular Treatment of Intracranial Aneurysms: Analysis of Early Angiographic and Clinical Outcomes
  • Short-Term Outcome of Intracranial Aneurysms Treated with Polyglycolic Acid/Lactide Copolymer-Coated Coils Compared to Historical Controls Treated with Bare Platinum Coils: A Single-Center Experience
  • Absent Relationship between the Coil-Embolization Ratio in Small Aneurysms Treated with a Single Detachable Coil and Outcomes
  • A Multicenter Study of 705 Ruptured Intracranial Aneurysms Treated with Guglielmi Detachable Coils
  • Three-Dimensional Packing with Complex Orbit Coils for the Endovascular Treatment of Intracranial Aneurysms
  • Coil Thickness and Packing of Cerebral Aneurysms: A Comparative Study of Two Types of Coils
  • Endovascular Treatment of Intracranial Aneurysms with Matrix Coils: A Preliminary Study of Immediate Post-treatment Results
  • Endovascular Treatment of Intracranial Wide-Necked Aneurysms Using Three-Dimensional Coils: Predictors of Immediate Anatomic and Clinical Results
  • Aneurysm Packing with HydroCoil Embolic System versus Platinum Coils: Initial Clinical Experience
  • Increasing the Packing of Small Aneurysms with Complex-Shaped Coils: An In Vitro Study
  • Long-Term Angiographic Recurrences After Selective Endovascular Treatment of Aneurysms With Detachable Coils
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Transradial Approach for Neuroendovascular Procedures: A Single-Center Review of Safety and Feasibility
  • Aneurysm Treatment in Acute SAH with Hydrophilic-Coated Flow Diverters under Single-Antiplatelet Therapy: A 3-Center Experience
  • Anatomic Snuffbox (Distal Radial Artery) and Radial Artery Access for Treatment of Intracranial Aneurysms with FDA-Approved Flow Diverters
Show more INTERVENTIONAL

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2020 Distinguished Reviewers
  • Press Releases

Resources

  • Evidence-Based Medicine Level Guide
  • How to Participate in a Tweet Chat
  • AJNR Podcast Archive
  • Ideas for Publicizing Your Research
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Share Your Art in Perspectives
  • Get Peer Review Credit from Publons
  • Moderate a Tweet Chat

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal
  • Position Statements

© 2021 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire