Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Other Publications
    • ajnr

User menu

  • Subscribe
  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
OtherINTERVENTIONAL

Percutaneous Direct Puncture Glue Embolization of High-Flow Craniofacial Arteriovenous Lesions: A New Circular Ring Compression Device with a Beveled Edge

C.W. Ryu, S.M. Whang, D.C. Suh, S.-M. Kim, Y.-J. Jang, H.-J. Kim, M.-J. Kim, S.E. Chang, J.P. Hong and S.J. Kim
American Journal of Neuroradiology March 2007, 28 (3) 528-530;
C.W. Ryu
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
S.M. Whang
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
D.C. Suh
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
S.-M. Kim
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Y.-J. Jang
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
H.-J. Kim
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M.-J. Kim
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
S.E. Chang
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J.P. Hong
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
S.J. Kim
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

Abstract

SUMMARY: The purpose of this study was to evaluate the efficacy of a newly designed circular ring compression device that allows safe and effective glue injection during preoperative embolization of high-flow superficial craniofacial arteriovenous malformations (AVMs). The device was used in 4 cases of craniofacial AVM with multiple feeding arteries and draining veins. It provided a safe glue injection route as well as effective compression of radiating multiple venous drainage routes.

Direct-puncture embolization with n-butyl 2-cyanoacrylate (n-BCA) is an effective and safe technique for preoperative devascularization of craniofacial arteriovenous malformations (AVMs).1–3 Both venous outflow and arterial inflow of the lesion should be limited during injection of the embolic material to avoid inadvertent distal migration of embolic material, including pulmonary embolization and occlusion of venous drainage. Manual compression of the draining vein is usually used for flow reduction.3 However, when an AVM has multiple channels of venous drainage, achieving successful blockage of blood flow is technically difficult with manual compression. Using a compression device for circumferential flow reduction can be more effective than manual digital compression; however, it is sometimes difficult to inject the glue while firmly maintaining compression of a high-flow vascular lesion.4 The purpose of this study was to introduce a newly designed circular ring device and to evaluate the safety and efficacy of the compression of the vascular lesion during glue embolization of a high-flow craniofacial AVM in the head and neck area.

Materials and Methods

We developed a circular ring device with a beveled edge of 2 different levels at the margin (Fig 1). The circular ring device was made by cutting the body portion of a plastic cup to create an elevated margin in two thirds of the circular portion of the cup body.

Fig 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 1.

A, Circular ring device with a beveled edge. The lower margin provides a comfortable injection window while maintaining compression through the elevated margin. Circular ring devices can be constructed by cutting a plastic cup body. B, Plan diagram of the device.

The circular ring device was used on 4 patients (4 men; range, 9–55 years of age) with scalp and neck AVMs (Table). These were superficially located high-flow lesions with multiple feeders and radiating venous drainage channels. We evaluated the pre-embolization angiographic findings (ie, feeding artery, draining vein, and nidus shape).

View this table:
  • View inline
  • View popup

Summary of clinical information and the findings of pre-embolization angiography

Embolization Technique

A selective pre-embolic angiogram was obtained and analyzed for its anatomic details, including arterial feeder, nidus, and venous drainage. The same angiography (compression angiography) was repeated after the circular ring device was placed at the verge of the vascular lesion and it compressed the lesion (Fig 2). Compression was regarded as ideal when the compression angiogram revealed the stasis of the flow within the boundary of the circular ring device without demonstration of venous drainage outside the device. It was necessary to adjust the compression force while obtaining the compression angiogram to properly compress the veins but not compress the arterial feeders completely to prevent blockage of the inflow.

Fig 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 2.

A 37-year-old man (patient 4) with a growing pulsatile mass and bruit caused by a long-standing high-flow arteriovenous fistula in the right anterior lower neck. A, Cutaneous branches of the right external carotid artery are dilated. Multiple dilated venous pouches are connected to the external jugular vein. B, During the compression around the shunt by the circular ring device, contrast medium stagnates within the device margin. C, Final angiogram obtained after glue embolization shows no further shunt. D, Surgical resection specimens were obtained by en bloc resection. Note the presence of glue in the dilated malformed vessels (arrow).

Once the position of the device and the degree of compression were determined, direct puncture with an 18-gauge needle (BD Angiocath Plus, Becton Dikinson Korea, Seoul, Korea) was done through the lower margin of the device while we compressed the elevated margin of the device. When the needle was inserted into the lesion and blood was returned through the needle, a direct puncture angiogram was obtained to confirm whether the needle tip was in the nidus, venous pouch, or arterial feeder. Although the needle tip can be placed in the nidus, venous pouch, or arterial feeder, the dilated venous sac next to the fistula seems to be the ideal puncture site because targeting the dilated venous sac is relatively easy and injected glue slowly regurgitates from the dilated vein into the fistula and then into the arterial feeders, leading to complete devascularization of the lesion while maintaining effective compression.

If the needle was securely positioned within the vascular space, a 30%–50% mixture of n-BCA (Histoacryl Blue, Braun, Melsungen, Germany) and iodized oil (Lipiodol, Laboratoire Guerbet, Roissy, France) was injected during compression of the verge of the AVM by the circular ring. The operator maintained the compression of the circular ring device until complete polymerization of the n-BCA and iodized oil mixture was obtained. Repeated puncture and n-BCA mixture injection were performed in case there was residual AVM. Migration of the glue cast was carefully monitored by high-quality fluoroscopy.

Results

The data of our 4 patients are summarized in the Table. Three had scalp lesions, and 1 had a lesion in the right lower neck (patient 4). On pre-embolization angiography, all lesions had multiple feeding arteries and multiple draining veins. The arterial supplies to the 3 scalp lesions (patients 1–3) were branches of superficial temporal arteries. Draining veins included the superficial scalp, supraorbital, and external jugular veins. An AVM, including a fistula lesion in the right anterior lower neck (patient 4), was supplied by branches of the facial artery, the superior thyroid artery, and the thyrocervical trunk and drained to multiple branches of the external jugular vein.

Successful devascularization was confirmed on postembolization angiography. A lesion in the anterior lower neck revealed a small number of residual feeders from the branch of the thyrocervical trunk, which was selected by a microcatheter and additionally embolized by using fragmented gelatin sponge (Gelfoam, Phadia, Uppsala, Sweden). In 4 cases, the glue cast was localized within and/or around the margin of the circular ring without distal migration during injection. The shape of the glue cast changed in 2 patients (patients 1 and 3), especially by using the 30% glue mixture while releasing the compression before complete polymerization.

Before surgical excision (from 1 to 3 days after embolization), skin necrosis was not demonstrated and pulsation of the AVM was not palpated at the lesion site. Complete resection was possible in all patients, with a clear resection margin during surgery. After surgical excision of the embolized AVM, all lesions were pathologically confirmed as vascular malformations.

Discussion

Because of the development of endovascular treatment techniques and the advantages of minimally invasive interventional procedures, endovascular embolization has become the treatment of choice for craniofacial AVM.3,5 Endovascular devascularization of a craniofacial AVM has also been used as an adjunct to surgery or as the definitive therapy. Even though any mass remaining after embolization was resected in our series, mainly for cosmetic reasons, regression of the mass effect can be expected after absorption of the thrombus during the clinical follow-up when surgical resection is not performed. Although endovascular glue embolization can be the definitive treatment, surgical resection may be performed in patients in whom a superficial palpable glue cast protrudes on the face, thereby causing cosmetic problems or forming a residual recanalized lesion on follow-up study.6–8 The follow-up period of assessment of complete cure is at least 1 year in the intracranial AVM.6

The direct puncture embolization of the venous pouch of an AVM has the advantage of reducing the risk of ischemia (ie, skin necrosis and compromise of the central retinal artery) and is technically simple compared with transarterial embolization.3 When a liquid embolic agent is used for devascularization of a high-flow arteriovenous shunt, the venous flow reduction is important to prevent complications. Inadvertent loss of embolic material into to the venous side of a shunt may lead to occlusion of normal venous outflow or even to a pulmonary embolism.5,9,10

Several blood-flow reduction methods that could be used for a liquid embolic agent during percutaneous embolization of an AVM have been documented and include manual compression of a draining vein by a digit,3 band ligation of a draining vein,5 temporary occlusion of a proximal artery by a metallic coil, and circumferential flow reduction by using a circular ring,4 and so forth.

The shape of the glue cast changed in 2 patients (patients 1 and 3), especially by using the 30% glue mixture while releasing the compression before complete polymerization. Although the cast remained in the venous side without causing any complication in our study, the change in shape may cause further distal migration of the glue cast. Therefore, we recommend using 40%–50% glue, depending on the treatment plan, because more than 50% glue becomes very hard during surgical resection.11 Although exact estimation of the polymerization time after glue injection is difficult, we think that 2 minutes should be enough for polymerization.11,12 In our 4 patients, the new circular ring device was effective for trapping the glue mixture within the venous sac of the craniofacial high-flow AVM and for occluding the arteriovenous shunt. Compared with the cookie-cutter technique using a simple ring device,4 our new devices were very convenient for compressing a lesion as well as safe and effective for injecting glue through the window formed by beveled edge of the device.

Footnotes

  • This work was supported by a grant (2006-143) from the Asan Institute for Life Sciences, Seoul, Korea

References

  1. ↵
    Barnwell SL, Halbach VV, Dowd CF, et al. Endovascular treatment of scalp arteriovenous fistulas associated with a large varix. Radiology 1989;173:533–39
    PubMed
  2. Mathis JM, DeNardo AJ, Jensen ME, et al. Arteriovenous fistula of the scalp after hair transplantation treated by endovascular embolization. Ann Plast Surg 1994;33:633–37
    CrossRefPubMed
  3. ↵
    Han MH, Seong SO, Kim HD, et al. Craniofacial arteriovenous malformation: preoperative embolization with direct puncture and injection of n-butyl cyanoacrylate. Radiology 1999;211:661–66
    PubMed
  4. ↵
    Duncan IC, Fourie PA. Circumferential flow reduction during percutaneous embolotherapy of extracranial vascular malformations: the “cookie-cutter” technique. AJNR Am J Neuroradiol 2003;24:1453–55
    Abstract/FREE Full Text
  5. ↵
    Yakes W. Management of extracranial head and neck and paraspinal vascular malformations. In: Connors JJ, Wojak JC, ed. Interventional Neuroradiology: Strategies and Practical Techniques. Philadelphia: Saunders;1999 :327–37
  6. ↵
    Yu SC, Chan MS, Lam JM, et al. Complete obliteration of intracranial arteriovenous malformation with endovascular cyanoacrylate embolization: initial success and rate of permanent cure. AJNR Am J Neuroradiol 2004;25:1139–43
    Abstract/FREE Full Text
  7. Rao VR, Mandalam KR, Gupta AK, et al. Dissolution of isobutyl 2-cyanoacrylate on long-term follow-up. AJNR Am J Neuroradiol 1989;10:135–41
    Abstract/FREE Full Text
  8. ↵
    Vinters HV, Lundie MJ, Kaufmann JC. Long-term pathological follow-up of cerebral arteriovenous malformations treated by embolization with bucrylate. N Engl J Med 1986;314:477–83
    PubMed
  9. ↵
    Kline JN, Ryals TJ, Galvin JR, et al. Pulmonary embolization and infarction: an iatrogenic complication of transcatheter embolization of a cerebral arteriovenous malformation with polyvinyl alcohol sponge. Chest 1993;103:1293–95
    PubMed
  10. ↵
    Duckwiler GR, Dion JE, Vinuela F, et al. Delayed venous occlusion following embolotherapy of vascular malformations in the brain. AJNR Am J Neuroradiol 1992;13:1571–79
    Abstract/FREE Full Text
  11. ↵
    Suh DC, Shi HB, Park SS, et al. Change of spontaneous reaction of glue and lipiodol mixture during embolization after the addition of tungsten powder: in vitro study. AJNR Am J Neuroradiol 2000;21:1277–79
    Abstract/FREE Full Text
  12. ↵
    Brothers MF, Kaufmann JC, Fox AJ, et al. n-Butyl 2-cyanoacrylate–substitute for IBCA in interventional neuroradiology: histopathologic and polymerization time studies. AJNR Am J Neuroradiol 1989;10:777–86
    Abstract/FREE Full Text
  • Received July 4, 2006.
  • Accepted after revision September 20, 2006.
  • Copyright © American Society of Neuroradiology
View Abstract
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 28 (3)
American Journal of Neuroradiology
Vol. 28, Issue 3
March 2007
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Percutaneous Direct Puncture Glue Embolization of High-Flow Craniofacial Arteriovenous Lesions: A New Circular Ring Compression Device with a Beveled Edge
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Percutaneous Direct Puncture Glue Embolization of High-Flow Craniofacial Arteriovenous Lesions: A New Circular Ring Compression Device with a Beveled Edge
C.W. Ryu, S.M. Whang, D.C. Suh, S.-M. Kim, Y.-J. Jang, H.-J. Kim, M.-J. Kim, S.E. Chang, J.P. Hong, S.J. Kim
American Journal of Neuroradiology Mar 2007, 28 (3) 528-530;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Percutaneous Direct Puncture Glue Embolization of High-Flow Craniofacial Arteriovenous Lesions: A New Circular Ring Compression Device with a Beveled Edge
C.W. Ryu, S.M. Whang, D.C. Suh, S.-M. Kim, Y.-J. Jang, H.-J. Kim, M.-J. Kim, S.E. Chang, J.P. Hong, S.J. Kim
American Journal of Neuroradiology Mar 2007, 28 (3) 528-530;
del.icio.us logo Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Materials and Methods
    • Results
    • Discussion
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Intraorbital access using fluoroscopic flat panel detector CT navigation and three-dimensional MRI overlay
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Clinical Significance of Prehospital Telecommunication Defined as the Critical Stroke Call Pathway in Acute Ischemic Stroke Requiring Intra-Arterial Recanalization Therapy
  • ADC Level is Related to DWI Reversal in Patients Undergoing Mechanical Thrombectomy: A Retrospective Cohort Study
  • Angiographically Occult Subarachnoid Hemorrhage: Yield of Repeat Angiography, Influence of Initial CT Bleed Pattern, and Sources of Diagnostic Error in 242 Consecutive Patients
Show more INTERVENTIONAL

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2021 Distinguished Reviewers
  • Press Releases

Resources

  • Evidence-Based Medicine Level Guide
  • How to Participate in a Tweet Chat
  • AJNR Podcast Archive
  • Ideas for Publicizing Your Research
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Share Your Art in Perspectives
  • Get Peer Review Credit from Publons
  • Moderate a Tweet Chat

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal
  • Position Statements

© 2022 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire