Research ArticleSPINE
A Comparison of Angiographic CT and Multisection CT in Lumbar Myelographic Imaging
J.-H. Buhk, E. Elolf, D. Jacob, H.-H. Rustenbeck, A. Mohr and M. Knauth
American Journal of Neuroradiology March 2008, 29 (3) 442-446; DOI: https://doi.org/10.3174/ajnr.A0853
J.-H. Buhk
E. Elolf
D. Jacob
H.-H. Rustenbeck
A. Mohr
References
- ↵Bartynski WS, Lin L. Lumbar root compression in the lateral recess: MR imaging, conventional myelography, and CT myelography comparison with surgical confirmation. AJNR Am J Neuroradiol 2003;24:348–60
- ↵Bischoff RJ, Rodriguez RP, Gupta K, et al. A comparison of computed tomography-myelography, magnetic resonance imaging, and myelography in the diagnosis of herniated nucleus pulposus and spinal stenosis. J Spinal Disord 1993;6:289–95
- Saint-Louis LA. Lumbar spinal stenosis assessment with computed tomography, magnetic resonance imaging, and myelography. Clin Orthop Relat Res 2001;122–36
- ↵Tsuchiya K, Katase S, Aoki C, et al. Application of multi-detector row helical scanning to postmyelographic CT. Eur Radiol 2003;13:1438–43
- ↵Kufeld M, Claus B, Campi A, et al. Three-dimensional rotational myelography. AJNR Am J Neuroradiol 2003;24:1290–93
- ↵Zellerhoff M, Scholz B, Ruehrnschopf EP, et al. Low contrast 3D reconstruction from C-arm data. Proc SPIE 2005;5745:646–55
- ↵Benndorf G, Strother CM, Claus B, et al. Angiographic CT in cerebrovascular stenting. AJNR Am J Neuroradiol 2005;26:1813–18
- Benndorf G, Claus B, Strother CM, et al. Increased cell opening and prolapse of struts of a Neuroform stent in curved vasculature: value of angiographic com-puted tomography: technical case report. Neurosurgery 2006;58:ONS-E380; discussion ONS-E380
- ↵Heran NS, Song JK, Namba K, et al. The utility of DynaCT in neuroendovascular procedures. AJNR Am J Neuroradiol 2006;27:330–32
- ↵Kalender WA. The use of flat-panel detectors for CT imaging [in German]. Radiologe 2003;43:379–87
- ↵Loose R, Wucherer M, Brunner T. [Visualization of 3D low contrast objects by CT cone-beam reconstruction of a rotational angiography with a dynamic solid body detector [in German]. RoFo 2005;S1:PO 160
- ↵Cohen J. Weighted kappa: nominal scale agreement with provision for scaled disagreement or partial credit. Psychol Bull 1968;70:213–20
- ↵Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977;33:159–74
- ↵
- ↵
- ↵Jakobsson U, Westergren A. Statistical methods for assessing agreement for ordinal data. Scand J Caring Sci 2005;19:427–31
- ↵Anxionnat R, Bracard S, Macho J, et al. 3D angiography. Clinical interest. First applications in interventional neuroradiology. J Neuroradiol 1998;25:251–62
- ↵Gray JE, Archer BR, Butler PF, et al. Reference values for diagnostic radiology: application and impact. Radiology 2005;235:354–58
- ↵
In this issue
Advertisement
A Comparison of Angiographic CT and Multisection CT in Lumbar Myelographic Imaging
J.-H. Buhk, E. Elolf, D. Jacob, H.-H. Rustenbeck, A. Mohr, M. Knauth
American Journal of Neuroradiology Mar 2008, 29 (3) 442-446; DOI: 10.3174/ajnr.A0853
Jump to section
Related Articles
- No related articles found.
Cited By...
This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.
- Andrew C. Glatz, Xiaowei Zhu, Matthew J. Gillespie, Brian D. Hanna, Jonathan J. RomeJACC: Cardiovascular Imaging 2010 3 11
- M. Söderman, D. Babic, S. Holmin, T. AnderssonNeuroradiology 2008 50 10
More in this TOC Section
Similar Articles
Advertisement