Data supplements
Supplemental Online Text and Figures
Files in this Data Supplement:
- Online Text and Figures (PDF) -
Online Figure 1: Grid-independence study. A, Influence of mesh resolution on the computation of the inflow/outflow region-separating line (zero normal-velocity contour line) on a plane across the neck of aneurysm 1 at peak systole. B, Influence of mesh resolution on the computation of normal-velocity profiles along a chord across the neck of aneurysm 1 at peak systole.
Online Figure 2: A, Inlet velocity profiles for Fourier analysis, exercise condition. Solid black line indicates 10 coefficients in the Fourier series; dashed gray line, 6 coefficients; dot-dashed black line, 3 coefficients. B, RRT. I, Ten Fourier coefficients. II, Six Fourier coefficients. III, Three Fourier coefficients.
- Online Text and Figures (PDF) -