Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Other Publications
    • ajnr

User menu

  • Subscribe
  • Alerts
  • Log in
  • Log out

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in
  • Log out

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
Research ArticleExpedited Publication

Safety of the Pipeline Embolization Device in Treatment of Posterior Circulation Aneurysms

T.J. Phillips, J.D. Wenderoth, C.C. Phatouros, H. Rice, T.P. Singh, L. Devilliers, V. Wycoco, S. Meckel and W. McAuliffe
American Journal of Neuroradiology August 2012, 33 (7) 1225-1231; DOI: https://doi.org/10.3174/ajnr.A3166
T.J. Phillips
aFrom the Department of Neurological Intervention and Imaging Western Australia (T.J.P., C.C.P., T.P.S., V.W., W.M.), Sir Charles Gairdner Hospital, Perth, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J.D. Wenderoth
cNeurointerventional Service (J.D.W.), Prince of Wales Hospital and Liverpool Hospital, Sydney, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C.C. Phatouros
aFrom the Department of Neurological Intervention and Imaging Western Australia (T.J.P., C.C.P., T.P.S., V.W., W.M.), Sir Charles Gairdner Hospital, Perth, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
H. Rice
bNeurointerventional Section (H.R., L.D.), Gold Coast Hospital, Surfers Paradise, Queensland, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T.P. Singh
aFrom the Department of Neurological Intervention and Imaging Western Australia (T.J.P., C.C.P., T.P.S., V.W., W.M.), Sir Charles Gairdner Hospital, Perth, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
L. Devilliers
bNeurointerventional Section (H.R., L.D.), Gold Coast Hospital, Surfers Paradise, Queensland, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
V. Wycoco
aFrom the Department of Neurological Intervention and Imaging Western Australia (T.J.P., C.C.P., T.P.S., V.W., W.M.), Sir Charles Gairdner Hospital, Perth, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
S. Meckel
dDepartment of Neuroradiology (S.M.), University Hospital Freiburg, Freiberg, Germany.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
W. McAuliffe
aFrom the Department of Neurological Intervention and Imaging Western Australia (T.J.P., C.C.P., T.P.S., V.W., W.M.), Sir Charles Gairdner Hospital, Perth, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: The published results of treating internal carotid artery aneurysms with the PED do not necessarily apply to its use in the posterior circulation because disabling brain stem infarcts can be caused by occlusion of a single perforator. In this multicenter study, we assessed the safety of PED placement in the posterior circulation.

MATERIALS AND METHODS: A prospective case registry was maintained of all posterior circulation aneurysms treated with PEDs at 3 Australian neurointerventional centers during a 27-month period. The objective was to assess the complications and aneurysm occlusion rates associated with posterior circulation PEDs.

RESULTS: Thirty-two posterior circulation aneurysms were treated in 32 patients. No deaths or poor neurologic outcomes occurred. Perforator territory infarctions occurred in 3 (14%) of the 21 patients with basilar artery aneurysms, and in all 3, a single PED was used. Two asymptomatic intracranial hematomas were recorded. No aneurysm rupture or PED thrombosis was encountered. The overall rate of permanent neurologic complications was 9.4% (3/32); all 3 patients had very mild residual symptoms and a good clinical outcome. Aneurysm occlusion was demonstrated in 85% of patients with >6 months of follow-up and 96% of patients with >1 year of follow-up.

CONCLUSIONS: The PED is effective in the treatment of posterior circulation aneurysms that are otherwise difficult or impossible to treat with standard endovascular or surgical techniques, and its safety is similar to that of stent-assisted coiling techniques. A higher clinical perforator infarction rate may be associated with basilar artery PEDs relative to the internal carotid artery.

ABBREVIATIONS:

mRS
modified Rankin Scale
PED
Pipeline Embolization Device
SFD
Silk flow diverter
TGA
Therapeutic Goods Association
WFNS
World Federation of Neurological Surgeons

The introduction of the PED (Chestnut Medical Technologies, Menlo Park, California) was a significant addition to the endovascular treatment options for anterior circulation intracranial aneurysms. Published registries have documented excellent aneurysm closure results with safety profiles comparable with or better than balloon-assisted or stent-supported coiling.1⇓⇓⇓⇓–6 Most cases included in publications to date are of anterior circulation aneurysms, mostly in the internal carotid artery, and the growing body of evidence can be reasonably applied to this anatomic subset.1⇓⇓⇓⇓–6 The relative paucity of posterior circulation aneurysms in the larger published series and the case reports of delayed thrombosis of posterior circulation PEDs serve as a reminder that experience and data associated with using PEDs to treat internal carotid artery aneurysms does not automatically apply to their use in the posterior circulation. The purpose of this multicenter prospective registry was to analyze the safety and results of using PEDs to treat posterior circulation aneurysms.

Materials and Methods

A prospective case registry was maintained of consecutive posterior circulation aneurysms treated with PEDs at 3 Australian neurointerventional centers between August 2009 and October 2011. The study included 32 patients, 21 of them female (ratio 1:1.91) (age range, 15–78 years; mean, 52 years; median, 52 years). Sixteen patients were current or ex-smokers. Seventeen cases are also included in other publications.5,7 Data were prospectively collected on patient demographics, clinical parameters, aneurysm characteristics, antiplatelet and anticoagulation regimens, and technical and clinical complications. The cases are detailed in the On-line Table.

All aneurysms included were judged by a multidisciplinary team as not satisfactorily treatable by standard endovascular or surgical techniques. Written informed consent was obtained from all patients and/or their families. Before the TGA approval of the PED, individual applications were made to the hospital administration and the TGA for use of the device on compassionate grounds.

All patients were loaded with clopidogrel (Plavix) and aspirin preoperatively. One center had access to point-of-care P2Y12 inhibition testing (VerifyNow; Accumetrics, San Diego, California), which allowed customization of loading schedules in response to inhibition levels.

For elective procedures, most patients were prescribed 5–7 days of either 75 mg or 150 mg daily of clopidogrel. Dosing regimens varied between centers, with 1 center preferring a shorter term, higher dose schedule of 300 mg daily for 2 days. Shorter regimens were used in cases of recent SAH, in most, 300 or 600 mg of clopidogrel on the day of the procedure.

All patients were prescribed dual antiplatelet therapy postoperatively. The duration varied with operator preference and patient compliance. Two patients stopped taking clopidogrel prematurely at 2 weeks (patient 16) and 3 months (patient 4). In 3 patients, the clopidogrel was stopped at 3 months, after aneurysm occlusion was demonstrated. In patient 9, the clopidogrel was stopped at 5 months to treat persistent aneurysm filling. Presently, clopidogrel has been stopped in 24 of 32 patients, 10 at 6 months or earlier, 5 between 6 and 12 months, and 9 at ≥12 months. In the 8 still taking clopidogrel, 7 are <6 months posttreatment, and 1 is between 6 and 12 months post-PED.

All patients were heparinized during stent deployment, titrated to an activated clotting time of >250 seconds or twice the baseline. All patients were heparinized postoperatively with a target activated partial thromboplastin time 2× normal. The duration varied with operator preference, 21 patients for 13–24 hours, 10 for >24 hours, and 1 for <24 hours. In 1 case involving sacrifice of a vertebral artery (patient 18), anticoagulation was continued for 1 week with subcutaneous enoxaparin.

All procedures were performed with the patient under general anesthetic by interventional neuroradiologists. Using a coaxial or triaxial guide-catheter system, we deployed all PEDs through a Marksman microcatheter (ev3; Irvine, California) under digital-subtraction fluoroscopy. A subjective decision about the number of PEDs was made by the operator at the time. Additional PEDs were used to bridge the neck of fusiform aneurysms, eliminate the impression of an inflow jet into the aneurysm post-PED, or decrease the aneurysm emptying relative to the parent vessel. Incomplete opening of a PED was remedied with balloon angioplasty when needed (HyperGlide; ev3) in 10 aneurysms. If used, endosaccular coils were deployed either before the PED or through a jailed microcatheter.

All patients were seen and examined by interventional neuroradiologists immediately postoperatively, daily during their inpatient admission, and in the outpatient clinic at 1, 3, and 6 months after discharge. Additional independent follow-up was also routinely performed by the referring neurologist or neurosurgeon, and all patients with neurologic complications were independently assessed by a neurologist. Clinical and imaging follow-up ranged from 4 to 39 months (mean, 21 months; median, 22 months) and was >6 months in 28/32 cases. CTA (if no coils were present) and MR imaging were used at various time points in several patients, depending on the clinical need. All patients had either CTA or MR imaging in the first 3 months. Twenty-seven patients have undergone a 6-month DSA; in patient 10, this was withheld due to renal failure, but aneurysm occlusion was demonstrated on MRA. Patients 29–32 are scheduled to have 6-month DSA in the next 60 days. Imaging findings detailing the presence of aneurysm occlusion, in-construct stenosis, and silent infarction were assessed. Delayed clinical complications and ongoing antiplatelet therapy compliance were assessed.

The primary objective of this study was to assess the complications associated with deploying PEDs in the posterior circulation. The outcome end points of this study are clinical complications and aneurysm occlusion.

Results

Twenty asymptomatic aneurysms were treated in 20 patients. Four aneurysms in 4 patients were treated after presentation with a focal acute2 or chronic2 mass-induced neurologic deficit. Eight aneurysms in 8 patients were treated with PEDs after recent rupture and SAH. Treatment was on days 0, 1, 2, 3, 11, 21, 24, and 26 post-SAH. Six were good clinical grades (WFNS 0–1), and 2 were poor grades (WFNS 4–5).

Two of the 8 patients with SAH were treated with PEDs after primary treatment with coiling (patient 9) and stent-coiling (patient 20) resulting in acute aneurysm recurrence during the same admission. Of the 20 asymptomatic patients, 6 had been previously treated with stent-coiling; 1, with coiling alone; and 1 was previously clipped. Neither of the 2 patients with acute mass effect had been previously treated. One of the 2 patients with chronic mass effect had been previously coiled.

Twelve berry aneurysms were included; 11 of these were wide-neck (dome/neck <1:6 or neck ≥4 mm), and 7 incorporated branch vessels. Twenty aneurysms classified as fusiform, blister, sidewall, or dissecting were included. Aneurysm size raged from 2 to 30 mm (mean, 9.7 mm; median, 10 mm).

In 21 patients, PED constructs were partially or entirely deployed within the basilar artery. Eleven of these were basilar tip–posterior cerebral artery P1 segment aneurysms, 8 were basilar trunk aneurysms, and 2 were vertebrobasilar junction aneurysms. Seven vertebral artery lesions, 1 posterior inferior cerebral artery lesion, and 3 posterior cerebral artery lesions were treated with PED constructs in the parent artery without involvement of the basilar artery. Only patient 4 had overlapping PEDs within the normal basilar artery. The first PED migrated downward for >5 minutes, uncovering the 2-mm blister sidewall aneurysm in the distal basilar trunk. A second PED was deployed with no adverse sequelae.

Forty-seven PEDs were deployed in 32 patients to treat 32 aneurysms. In 1 patient, 4 PEDs were used to form the construct, in 2 patients 3 PEDs, and in 8 patients 2 PEDs were used. Calibers ranged from 2.5 to 4.75 mm (median, 3.25 mm; lengths, 10–30 mm; median, 18 mm). In 11 patients (6 asymptomatic, 4 SAH, and 1 acute mass effect), endosaccular coils were also deployed. Coil sacrifice of the contralateral vertebral artery distal to the posterior inferior cerebral artery origin was performed in all 3 patients with vertebrobasilar junction aneurysms (patients 3, 16, and 18). After PED deployment across the junction of the ipsilateral vertebral artery and the basilar artery, the contralateral vertebral artery filled the aneurysm sac. This necessitated sacrifice of this vertebral artery (Fig 1).

Fig 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 1.

Patient 18 was a 43-year-old man who presented with WFNS grade 4 SAH. A multilocular vertebrobasilar junction aneurysm at a fenestration was treated with stent-assisted Enterprise (Cordis, Miami Lakes, Florida) coiling, with the stent in the left limb of the fenestration. The patient had a stormy course, including symptomatic vasospasm requiring angioplasty, but made an excellent recovery. Follow-up angiography documents a growing aneurysm and some compaction. A, B, C, and D, Anteroposterior subtracted DSA studies. A, Filling of the aneurysm from the right and left sides (black arrow at the approximate margin of Enterprise stent). A PED was placed within the left vertebrobasilar Enterprise stent, and the endoleak was treated with coil occlusion of the right vertebral artery and a right fenestrated limb (B and C). Follow-up angiogram (D) at 12 months documents patency of the construct without aneurysm filling.

Previous publications have recommended that if a PED is used to treat a recently ruptured aneurysm, it should be combined with endosaccular coiling whenever possible.5,7 Patients 4 and 10 had PED constructs to treat blister aneurysms that were too small to support coils. Patient 24 was treated with a construct of 2 PEDs for a 6 × 20 mm dissecting fusiform vertebral artery aneurysm with no stable sac to hold the coils. The 5 other recently ruptured aneurysms included in the study were packed with coils before1 or at the time of PED deployment.4

Complications

Acute Complications.

A single patient had a groin hematoma, which resolved without treatment. A recurrent multilobed vertebrobasilar junction aneurysm in a 37-year-old man had originally been treated with stent-assisted coiling after SAH 1 year earlier (patient 18). The recanalized aneurysm was treated with a PED spanning the distal left vertebral and proximal basilar arteries, with coil deconstruction of the right vertebral artery distal to the posterior inferior cerebral artery. He awoke from the procedure with unilateral right-sided deafness, no facial nerve weakness, and no cerebellar signs. MR imaging demonstrated no brain stem or cerebellar infarction. In the absence of an infarct at the cochlear nucleus, the presumption is that the eighth cranial nerve was damaged. An embolus into the labyrinthine artery (anterior inferior cerebellar artery branch) was possible, but the absence of a cerebellar or facial nerve infarction is unusual. Another possibility is a perforator infarct to the eighth nerve due to the ipsilateral vertebral artery sacrifice. His mRS score was 1 at 6-month follow-up.

After PED and coil treatment of a ruptured fusiform basilar tip–posterior cerebral artery aneurysm, patient 7 was confused on day 1 postprocedure. CT demonstrated a left cerebellar tonsillar 2-cm hematoma and a small 5-mm anterior right thalamic lacune (Fig 2). The patient's confusion resolved within 48 hours, and he was discharged home 13 days post-SAH with an mRS score of 0 at 1 month. No other infarction was detected at 3-month MR imaging.

Fig 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 2.

Patient 7 was a 64-year-old man who presented with WFNS clinical grade 1 SAH. Anteroposterior (AP) subtracted DSA (A) documents a fusiform aneurysm of the right P1 segment (black arrow, left superior cerebellar artery). A single PED construct was placed from the basilar artery through the fusiform aneurysm into the distal P1-P2 junction, with coiling of the aneurysm sac. Postoperative CT at 24 hours (B and C) documents a small left cerebellar hemorrhage and a new mesial right anterior thalamic lacune. The patient made an excellent recovery and was discharged home on day 13 post-subarachnoid hemorrhage. Follow-up angiography at 12 months (AP subtracted DSA, D) documents occlusion of the aneurysm and patency of the cerebellar artery and P1 segment.

Delayed Ischemic Strokes.

An enlarging wide-neck 10-mm basilar tip aneurysm in a 56-year-old woman (patient 17) was treated electively with coils and a PED as a neck construct deployed from the left P1 posterior cerebral artery into the basilar trunk (Fig 3). No immediate complications were encountered. She re-presented to the hospital on day 25, with initially transient, then stuttering progressive hemianesthesia and dysarthria, while still taking clopidogrel and aspirin. On examination, she had left upper limb incoordination, mild upper limb weakness, and gait ataxia. MR imaging demonstrated an acute right ventral pontine (basilar perforating artery territory) infarct, and same-day DSA demonstrated a widely patent PED construct with no thrombus or visible branch artery occlusion. The patient had 2 old lacunes predating treatment. With rehabilitation, her brain stem signs improved greatly, and at 6 months, she had an mRS score of 1 as assessed by an independent neurologist.

Fig 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 3.

Patient 17 was a woman 56 years of age with a 6 × 10 mm (height × neck width) basilar tip aneurysm with rapid growth, measuring 2.5 mm 6 years previously. There was incorporation of the left P1 and, to a lesser extent, the right P1 with a patent left posterior communicating artery. The patient had a history of hypertension with triple medical therapy and depression. A, C, E, and F, Subtracted DSA anteroposterior images of the basilar artery. In view of the very unfavorable dome/neck ratio (0:6), we decided to use the PED as a stent-assist construct in this instance because the device would fill the vessel and markedly narrow the neck without “cutting the corners” as other coiling assist constructs tend to. The PED was placed in the left P1 (native image, B) because the right posterior communicating artery was hypoplastic. Coiling was successful with a small locule and maintenance of the posterior communicating artery on the left (C). The patient remained well with appropriate platelet inhibition. After she re-presented with a stroke, MR imaging (D) depicts a right paramedian pontine infarct at the level of the proximal third of the stent within the basilar artery. Angiography performed the same day (E) shows that the aneurysm is occluded, apart from a small side locule, and there is no in-construct stenosis or thrombosis. Follow-up angiography at 11 months (F) shows that the posterior communicating artery and stent are widely patent. The small right locule is significantly smaller.

A 47-year-old woman with an unruptured basilar tip aneurysm was treated electively with a single PED from the left P1 posterior cerebral artery into the basilar trunk (patient 27). She had no neurologic deficit or any other complication in the first 72 hours postoperatively and was ready to be discharged from the hospital. On day 3, she reported sudden-onset visual and balance disturbances. On clinical examination, she had upbeat vertical nystagmus, impaired convergence, and difficulty with conjugate gaze on pursuit. During the next week, she developed right-leaning ataxia, and in weeks 2 and 3, she developed right-sided lower limb spasticity. MR imaging performed on days 4, 18, and 28 did not demonstrate any unequivocal brain stem lesions; however, the clinical picture was ascribed to a brain stem (basilar perforating artery territory) infarction by an independent neurologist. With rehabilitation, her deficits improved, with mild subjective hamstring tightness her only residuum. She returned to work at 3 months with an mRS score of 1, and on MR imaging on day 28, the aneurysm was occluded.

Delayed Transient Ischemic Attacks.

A 61-year-old woman with multiple vascular risk factors was treated with a PED and right vertebral artery sacrifice for a recurrent left vertebrobasilar junction aneurysm that had been originally treated with stent-assisted coiling and Onyx (ev3) embolization 7 years earlier (patient 16). At 2–3 months postprocedure, the patient stopped her aspirin and clopidogrel against medical advice. At 97 days postprocedure, the patient re-presented with a transient episode of expressive dysphasia. This resolved in <24 hours. No acute ischemic lesion was detected on MR imaging. She was reloaded with clopidogrel as a precaution and remains well.

Complications Demonstrated on Imaging without Clinical Sequelae.

All patients had parenchymal brain imaging with CT or MR imaging within 3 months of PED treatment. Patient 24 was a 48-year-old man treated with a construct of 2 PEDs for a 6 × 20 mm dissecting fusiform vertebral artery aneurysm on day 2 after WFNS grade 5 SAH. A postoperative CT demonstrated small bilateral retrocerebellar subdural hematomas. These were asymptomatic and resolved with conservative management.

In-Construct Stenosis.

Patient 20 had in-construct stenosis without flow limitation demonstrated on 6-month DSA. On 12-month DSA, this had resolved.

Summary of Complications

No aneurysms ruptured. No stent thrombosis was encountered. No poor neurologic outcomes (dependency or death) occurred.

Three (9.4%) of 32 patients had permanent neurologic deficits (patients 17, 18, and 27). All 3 of these patients have only minor residual symptoms (loss of vocal volume, unilateral hamstring tightness, and unilateral deafness, respectively) and are independent and have returned to work (mRS 1).

Three (9.4%) of the 32 cases were complicated by infarction in the territory of a perforator covered by the PED construct (patients 7, 17, and 27); the latter 2 of these had permanent neurologic deficits and were included in the group above. Patient 7 had a unilateral thalamic infarct with transient confusion but no permanent deficit. These patients represent 3 (14%) of the 21 with PED constructs in the basilar artery. None of these 3 patients had overlapping PEDs.

One asymptomatic cerebellar hematoma (patient 7) and 1 asymptomatic subdural hematoma (patient 24) were detected.

Aneurysm Occlusion

Twenty-four aneurysms have occluded. Of the 32 patients included in the study, 28 had >6 months' follow-up, and in 24 (86%) of these patients, aneurysm occlusion has been demonstrated. Twenty-three patients had >1 year follow-up, and in 22 (96%) of these patients, aneurysm occlusion was demonstrated. Aneurysm occlusion was demonstrated in all (100%) of the 8 patients with >2-year follow-up. Nine patients in whom coils were used with PEDs had >6-month imaging follow-up, and 7 of the aneurysms were occluded. Nine patients in whom the PED was deployed across the basilar bifurcation had >6-month imaging follow-up, and 7 of the aneurysms were occluded.

Late Aneurysm Occlusion.

A fusiform blister aneurysm of the left P1/P2 segment in patient 9 was treated with a PED and coils on day 11 post-WFNS grade 4 SAH after initial stent coiling (Solitaire; ev3) failed with rapid early aneurysm recurrence. At 18 months, a residual 4-mm bleb-like residuum remained, which had continued to increase in size after clopidogrel had been stopped at 5 months. At 22 months, 17 months after cessation of clopidogrel, complete aneurysm closure was demonstrated on DSA.

Aneurysms Not Occluded beyond 12 Months.

Patient 12 was a 69-year-old man who presented with acute brain stem compression from a 15-mm basilar artery sidewall aneurysm. This was treated with a construct of 2 PEDs and endosaccular coils. His clinical signs and the brain stem compression and edema on MR imaging resolved, but serial follow-up DSA and MRA demonstrated persistent aneurysm filling, probably due to marked angulation of his tortuous basilar artery at the level of the aneurysm. Twenty months after the initial treatment, a third PED was deployed in the construct across the aneurysm neck. This was well-tolerated, and imaging follow-up is pending.

Discussion

Most cases published to date are of internal carotid artery aneurysms,1,2,5⇓⇓⇓–9 and extrapolations can reasonably be made from these data when discussing PED treatment of unruptured internal carotid artery aneurysms with other clinicians or with patients. However the volume of published data on using PEDs to treat posterior circulation aneurysms is much smaller, and the carotid data cannot automatically be applied to this group.

The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms (PITA) study included only 1 basilar and 1 vertebral artery aneurysm,6 the Buenos Aires article had 3 basilar artery and 5 vertebral artery aneurysms,1 and the Budapest series had 1 basilar artery aneurysm.2 None reported ischemic or hemorrhagic complications in patients with posterior circulation aneurysms, and the posterior aneurysms were all occluded.

Fisher et al3 included 22 posterior circulation aneurysms in their series of 101. Three of the 5 serious clinical complications were in patients with posterior circulation aneurysms: 2 acute cerebellar hemorrhages within 24 hours of elective basilar artery aneurysm treatment and a fatal basilar artery thrombosis after clopidogrel cessation. De Barros Faria et al10 published a series of 23 dissecting aneurysms treated with PEDs, 11 after SAH. Twenty-one were posterior circulation lesions, with 10 in the basilar artery. One patient with a vertebral artery lesion had an embolic stroke. Six of the 21 (29%) patients with posterior circulation aneurysms had complete aneurysm closure.10 A report of 3 patients treated with PEDs in the setting of recent aneurysm rupture included 1 basilar artery aneurysm. MR imaging in this patient documented a clinically silent pontine infarct.11

Delayed aneurysm rupture and delayed construct thrombosis are uncommon complications that are increasingly being reported. A fatal spontaneous delayed rupture of a previously unruptured large posterior inferior cerebral artery aneurysm following treatment with a PED and a series of 2 delayed internal carotid artery aneurysm ruptures after treatment with the PED have been published.12,13 Recent case reports have documented 3 very late construct occlusions in posterior circulation cases, 2 of them fatal.14,15

The SFD (Balt Extrusion, Montmorency, France) is another flow-diverting device with a similar concept. Early reports of delayed aneurysm rupture led to the manufacturers issuing a Medical Device Alert, instructing physicians not to use the device without coils, due to the “potential for patient death.”16⇓⇓–19 In the largest published Silk series, Byrne et al20 reported 14% parent artery occlusion, 4% permanent neurologic complications, 8% mortality, and complete aneurysm occlusion in 49%. Basilar artery aneurysms in 3 of 7 patients had clinical complications, 2 fatal. Lubicz et al21 included 4 basilar artery aneurysms in their Silk series of 29. Two of the 4 patients had delayed strokes, and 1 aneurysm was occluded successfully. In a series of 24 patients with 5 aneurysms in the posterior circulation, Tahtinen et al22 reported a 67% primary technical success, a need for intra-arterial abciximab in 17%, 15% parent artery thrombosis at follow-up, 4% mortality, and 70% aneurysm occlusion. Kulscar et al23 published 12 cases of basilar artery aneurysms treated with SFDs, 2 acutely after SAH. There were 4 strokes: 1 stent thrombosis and 3 perforator infarcts. Fifty-eight percent aneurysm occlusion was documented.23 A series of 31 posterior circulation fusiform aneurysms comprised 4 that were treated with SFDs. One of the 3 patients with basilar artery aneurysms had a stroke at 2 weeks, causing hemiparesis.24

The vertebrobasilar system supplies the unforgivingly eloquent rhombencephalon and mesencephalon and differs embryologically from the anterior circulation.25 Severe and bilateral disabling brain stem infarcts can be caused by occlusion of a single perforator that is invisible on angiography.3,10,11,20,⇓⇓⇓–24 Perforator infarction has also been reported after overlapped PED constructs in the anterior cerebral artery A1 and middle cerebral artery M1 segments.6,26 A series of 26 flow-diverter treatments in the anterior, middle, and posterior cerebral arteries recorded ischemic events that were reversible in 7.4% and permanent in 3.7%.27

In our study, PEDs were deployed in the basilar artery in 22 patients; 1 of these with 2 overlapping PEDs was in the normal basilar artery. Perforator territory infarctions occurred in 3 (14%) of the 21 basilar artery aneurysms, and in all 3, a single PED was used. No visible perforators were lost in these 3 patients. Perhaps there is sufficient flow demand to maintain DSA-visible perforators in the presence of a single PED.

Mortality was zero. The rate of permanent neurologic complications was 9.4% (3/32); all 3 had very mild residual symptoms and a good clinical outcome. Although clinical follow-up was >6 months in 28 of 32 patients, we are mindful that very late stent occlusions have been reported.8,9 In our study, the PED proved to be an effective treatment for posterior circulation aneurysms with high rates of aneurysm closure (91% of cases with >1-year follow-up, and 86% of those with >6-month follow-up). Large series of stent-assisted coiling report 5%–7% permanent neurologic complications, and 24%–28%, incomplete aneurysm occlusion.9,28 A series of 19 patients treated with a Y-stent placement technique for basilar tip aneurysms recorded initial complications of 32%, delayed thromboembolic complications in 11, and aneurysm closure in 63%.29

Conclusions

The PED is effective in the treatment of posterior circulation aneurysms that are otherwise difficult or impossible to treat with standard endovascular or surgical techniques. The major stroke and mortality rate was zero in this series, but minor permanent neurologic deficits were observed in 3/32 (9.4%) patients. Perforator infarctions were documented in 3 (14%) of the 21 patients with basilar artery aneurysms. The limited data available, including this study, suggest that a higher clinical perforator infarction rate is associated with use of the PED in the basilar artery relative to its more widespread use in the internal carotid artery. This serves as a reminder that though it is a very effective device, the PED should be reserved for cases not treated easily or effectively with balloon-assisted or scaffolding-type stent assistance.

Footnotes

  • Disclosures: Jason Wenderoth—UNRELATED: Employment: ev3, Comments: I am one of the Asia-Pacific proctors for Onyx and the Pipeline Embolization Device manufactured by ev3. During the past 3 years, on 2 occasions, I have been paid a daily wage plus travel and accommodation expenses to travel to other cities to teach other physicians how to use these devices. Hal Rice—UNRELATED: Consultancy: ev3 proctor, Travel/Accommodations/Meeting Expenses Unrelated to Activities Listed: ev3 meeting sponsorship. Tejinder Singh—UNRELATED: ev3, Comments: Travel and accommodation only to attend the Neuroexchange meeting 2009 in Noosa, Australia. No money was paid to me or my institution. Victor Wycoco—UNRELATED: Travel/Accommodations/Meeting Expenses Unrelated to Activities Listed: ev3 sponsored a nationwide Pipeline Symposium in 2011 (to discuss international and national experience with the stent to date) where accommodation and travel was sponsored. No monies were given directly to me. This study was not discussed at the meeting. Stephan Meckel—UNRELATED: Board Membership: Member of independent Core Lab for Pipeline for Uncoilable or Failed Aneurysms and Complete Occlusion of Coilable Aneurysms trials, Comments: I received honoraria from Chestnut Medical Technologies Inc/ev3.

References

  1. 1.↵
    1. Lylyk P,
    2. Miranda C,
    3. Ceratto R,
    4. et al
    . Curative endovascular reconstruction of cerebral aneurysms with the Pipeline embolization device: the Buenos Aires experience. Neurosurgery 2009;64:632–42
    CrossRefPubMed
  2. 2.↵
    1. Szikora I,
    2. Berentei Z,
    3. Kulcsar Z,
    4. et al
    . Treatment of intracranial aneurysms by functional reconstruction of the parent artery: the Budapest experience with the Pipeline embolization device. AJNR Am J Neuroradiol 2010;31:1139–47
    Abstract/FREE Full Text
  3. 3.↵
    1. Fischer S,
    2. Vajda Z,
    3. Aguilar Perez M,
    4. et al
    . Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissections. Neuroradiology 2012;54:369–82
    CrossRefPubMed
  4. 4.↵
    1. Lubicz B,
    2. Collignon L,
    3. Raphaeli GØ,
    4. et al
    . Pipeline flow-diverter stent for endovascular treatment of intracranial aneurysms: preliminary experience in 20 patients with 27 aneurysms. World Neurosurg 2011;76:114–19
    CrossRefPubMed
  5. 5.↵
    1. McAuliffe W,
    2. Wycoco V,
    3. Rice H,
    4. et al
    . Immediate and midterm results following treatment of unruptured intracranial aneurysms with the Pipeline embolization device. AJNR Am J Neuroradiol 2012;33:164–70
    Abstract/FREE Full Text
  6. 6.↵
    1. Nelson PK,
    2. Lylyk P,
    3. Szikora I,
    4. et al
    . The Pipeline embolization device for the intracranial treatment of aneurysms trial. AJNR Am J Neuroradiol 2011;32:34–40
    Abstract/FREE Full Text
  7. 7.↵
    1. McAuliffe W,
    2. Wenderoth JD
    . Immediate and midterm results following treatment of recently ruptured intracranial aneurysms with the Pipeline embolization device. AJNR Am J Neuroradiol 2012;33:487–93
    Abstract/FREE Full Text
  8. 8.↵
    1. Piotin M,
    2. Blanc R,
    3. Spelle L,
    4. et al
    . Stent-assisted coiling of intracranial aneurysms: clinical and angiographic results in 216 consecutive aneurysms. Stroke 2010;41:110–15
    Abstract/FREE Full Text
  9. 9.↵
    1. Fiorella D,
    2. Albuquerque FC,
    3. Woo H,
    4. et al
    . Neuroform stent assisted aneurysm treatment: evolving treatment strategies, complications and results of long term follow-up. J NeuroInterv Surg 2010;2:16–22
    Abstract/FREE Full Text
  10. 10.↵
    1. de Barros Faria M,
    2. Castro RN,
    3. Lundquist J,
    4. et al
    . The role of the Pipeline embolization device for the treatment of dissecting intracranial aneurysms. AJNR Am J Neuroradiol 2011;32:2192–95
    Abstract/FREE Full Text
  11. 11.↵
    1. Martin AR,
    2. Pablo Cruz J,
    3. Matouk CC,
    4. et al
    . The Pipeline flow-diverting stent for exclusion of ruptured intracranial aneurysms with difficult morphologies. Neurosurgery 2012;70 (1 suppl operative): 21–28 discussion 28
    CrossRefPubMed
  12. 12.↵
    1. Hampton T,
    2. Walsh D,
    3. Tolias C,
    4. et al
    . Mural destabilization after aneurysm treatment with a flow-diverting device: a report of two cases. J NeuroInterv Surg 2011;3:167–71
    Abstract/FREE Full Text
  13. 13.↵
    1. Chow M,
    2. McDougall C,
    3. O'Kelly C,
    4. et al
    . Delayed spontaneous rupture of a posterior inferior cerebellar artery aneurysm following treatment with flow diversion: a clinicopathologic study of the Pipeline embolization device for the treatment of dissecting intracranial aneurysms. AJNR Am J Neuroradiol 2012;33:E46–51
    Abstract/FREE Full Text
  14. 14.↵
    1. Fiorella D,
    2. Hsu D,
    3. Woo HH,
    4. et al
    . Very late thrombosis of a Pipeline embolization device construct: case report. Neurosurgery 2010;67: onsE313–14, discussion onsE314
  15. 15.↵
    1. Klisch J,
    2. Turk A,
    3. Turner R,
    4. et al
    . Very late thrombosis of flow-diverting constructs after the treatment of large fusiform posterior circulation aneurysms. AJNR Am J Neuroradiol 2011;32:627–32
    Abstract/FREE Full Text
  16. 16.↵
    1. Turowski B,
    2. Macht S,
    3. Kulcsar Z,
    4. et al
    . Early fatal hemorrhage after endovascular cerebral aneurysm treatment with a flow diverter (Silk-Stent): do we need to rethink our concepts? Neuroradiology 2011;53:37–41
    CrossRefPubMed
  17. 17.↵
    1. Kulcsar Z,
    2. Houdart E,
    3. Bonafe A,
    4. et al
    . Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment. AJNR Am J Neuroradiol 2011;32:20–25
    Abstract/FREE Full Text
  18. 18.↵
    1. Cloft HJ
    . Flow diversion for cerebral aneurysms: a cautionary tale of the Pipeline embolization device for the treatment of dissecting intracranial aneurysms. AJNR Am J Neuroradiol 2011;32: 26
  19. 19.↵
    Medical Device Alert: Intracranial Stent Manufactured by Balt Extrusion (MDA/2010/023). http://www.mhra.gov.uk/Publications/Safetywarnings/MedicalDeviceAlerts/CON076289. Accessed on 3 March, 2012.
  20. 20.↵
    1. Byrne JV,
    2. Beltechi R,
    3. Yarnold JA,
    4. et al
    . Early experience in the treatment of intra-cranial aneurysms by endovascular flow diversion: a multicentre prospective study. PLoS ONE 2010;5:e12492
    CrossRefPubMed
  21. 21.↵
    1. Lubicz B,
    2. Collignon L,
    3. Raphaeli G,
    4. et al
    . Flow-diverter stent for the endovascular treatment of intracranial aneurysms: a prospective study in 29 patients with 34 aneurysms. Stroke 2010;41:2247–53
    Abstract/FREE Full Text
  22. 22.↵
    1. Tahtinen OI,
    2. Manninen HI,
    3. Vanninen RL,
    4. et al
    . The Silk flow diverting stent in the endovascular treatment of complex intracranial aneurysms: technical aspects and mid-term results in 24 consecutive patients. Neurosurgery 2012;70:617–23, discussion 623–24
    CrossRefPubMed
  23. 23.↵
    1. Kulcsar Z,
    2. Ernemann U,
    3. Wetzel SG,
    4. et al
    . High-profile flow diverter (Silk) implantation in the basilar artery: efficacy in the treatment of aneurysms and the role of the perforators. Stroke 2010;41:1690–96
    Abstract/FREE Full Text
  24. 24.↵
    1. Raphaeli G,
    2. Collignon L,
    3. Bruneau M,
    4. et al
    . Endovascular treatment of posterior circulation fusiform aneurysms: single-centre experience in 31 patients. Neurosurgery 2011 Mar 23. [Epub ahead of print]
  25. 25.↵
    1. Charles R
    . Normal and abnormal embryology and development of the intracranial vascular system. Neurosurg Clin N Am 2010;21:399–426
    CrossRefPubMed
  26. 26.↵
    1. van Rooij WJ,
    2. Sluzewski M
    . Perforator infarction after placement of a Pipeline flow-diverting stent for an unruptured A1 aneurysm. AJNR Am J Neuroradiol 2010;31:E43–44
    FREE Full Text
  27. 27.↵
    1. Pistocchi S,
    2. Blanc R,
    3. Bartolini B,
    4. et al
    . Flow diverters at and beyond the level of the circle of Willis for the treatment of intracranial aneurysms. Stroke 2012;43:1032–38
    Abstract/FREE Full Text
  28. 28.↵
    1. Mocco J,
    2. Snyder KV,
    3. Albuquerque FC,
    4. et al
    . Treatment of intracranial aneurysms with the Enterprise stent: a multicenter registry. J Neurosurg 2009;110:35–39
    CrossRefPubMed
  29. 29.↵
    1. Spiotta AM,
    2. Gupta R,
    3. Fiorella D,
    4. et al
    . Mid-term results of endovascular coiling of wide-necked aneurysms using double stents in a Y configuration. Neurosurgery 2011;69: 421
  • Received December 21, 2011.
  • Accepted after revision April 5, 2012.
  • © 2012 by American Journal of Neuroradiology
View Abstract
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 33 (7)
American Journal of Neuroradiology
Vol. 33, Issue 7
1 Aug 2012
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Safety of the Pipeline Embolization Device in Treatment of Posterior Circulation Aneurysms
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Safety of the Pipeline Embolization Device in Treatment of Posterior Circulation Aneurysms
T.J. Phillips , J.D. Wenderoth, C.C. Phatouros, H. Rice, T.P. Singh, L. Devilliers, V. Wycoco, S. Meckel, W. McAuliffe
American Journal of Neuroradiology Aug 2012, 33 (7) 1225-1231; DOI: 10.3174/ajnr.A3166

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Safety of the Pipeline Embolization Device in Treatment of Posterior Circulation Aneurysms
T.J. Phillips , J.D. Wenderoth, C.C. Phatouros, H. Rice, T.P. Singh, L. Devilliers, V. Wycoco, S. Meckel, W. McAuliffe
American Journal of Neuroradiology Aug 2012, 33 (7) 1225-1231; DOI: 10.3174/ajnr.A3166
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • References
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • Flow Diversion of Posterior Circulation Aneurysms: Systematic Review of Disaggregated Individual Patient Data
  • Virtual simulation with Sim&Size software for Pipeline Flex Embolization: evaluation of the technical and clinical impact
  • Flow diverters for ruptured posterior circulation perforator aneurysms: multicenter experience and literature review
  • Outcome of intracranial flow diversion according to the antiplatelet regimen used: a systematic review and meta-analysis
  • Y-configuration stenting for coiling of wide-neck bifurcation aneurysms using Low-profile Visualized Intraluminal Support Junior
  • Preliminary experience with the use of low profile visualized intraluminal support device in basilar artery for aneurysm treatment
  • Comparison of Pipeline Embolization Device Sizing Based on Conventional 2D Measurements and Virtual Simulation Using the Sim&Size Software: An Agreement Study
  • LVIS Blue as a low porosity stent and coil adjuvant
  • Risk of Branch Occlusion and Ischemic Complications with the Pipeline Embolization Device in the Treatment of Posterior Circulation Aneurysms
  • A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies
  • Early angiographic signs of acute thrombus formation following cerebral aneurysm treatment with the Pipeline embolization device
  • Thrombogenicity of flow diverters in an ex vivo shunt model: effect of phosphorylcholine surface modification
  • Ophthalmic artery occlusion after Pipeline Embolization Device placement with reconstitution of flow via an endoleak: a report of two cases
  • First US experience with Pipeline Flex with Shield Technology using aspirin as antiplatelet monotherapy
  • Treatment of posterior circulation non-saccular aneurysms with flow diverters: a single-center experience and review of 56 patients
  • Use of Platelet Function Testing Before Pipeline Embolization Device Placement: A Multicenter Cohort Study
  • FRED Flow Diverter: A Study on Safety and Efficacy in a Consecutive Group of 50 Patients
  • Pipeline embolization device for the treatment of vertebral artery aneurysms: the fate of covered branch vessels
  • Intra-DIC (distal intracranial catheter) deployment of the Pipeline embolization device: a novel rescue strategy for failed device expansion
  • Republished: Successful treatment of a giant pediatric fusiform basilar trunk aneurysm with surpass flow diverter
  • Posterior Inferior Cerebellar Artery Patency after Flow-Diverting Stent Treatment
  • Flow diversion of large internal carotid artery aneurysms with the surpass device: impressions and technical nuance from the initial North American experience
  • Republished: The first North American use of the Pipeline Flex flow diverter
  • Flow diverter stent treatment for ruptured basilar trunk perforator aneurysms
  • Classification of cavernous internal carotid artery tortuosity: a predictor of procedural complexity in Pipeline embolization
  • Long-Term Follow-Up Results following Elective Treatment of Unruptured Intracranial Aneurysms with the Pipeline Embolization Device
  • A reappraisal of the Pipeline embolization device for the treatment of posterior circulation aneurysms
  • Posterior circulation flow diversion: a single-center experience and literature review
  • Endoluminal Reconstruction for Nonsaccular Aneurysms of the Proximal Posterior Cerebral Artery with the Pipeline Embolization Device
  • Successful treatment of a giant pediatric fusiform basilar trunk aneurysm with surpass flow diverter
  • The FRED Flow-Diverter Stent for Intracranial Aneurysms: Clinical Study to Assess Safety and Efficacy
  • Use of thromboelastography to tailor dual-antiplatelet therapy in patients undergoing treatment of intracranial aneurysms with the Pipeline embolization device
  • Extra-Aneurysmal Flow Modification Following Pipeline Embolization Device Implantation: Focus on Regional Branches, Perforators, and the Parent Vessel
  • Retrograde trans-anterior communicating artery rescue of unopened Pipeline Embolization Device with balloon dilation: complication management
  • The first North American use of the Pipeline Flex flow diverter
  • Heterogeneous practice patterns regarding antiplatelet medications for neuroendovascular stenting in the USA: a multicenter survey
  • Platelet function inhibitors and platelet function testing in neurointerventional procedures
  • Endovascular treatment of fusiform intracranial vertebral artery aneurysms using reconstructive techniques
  • Use of Flow-Diverting Devices in Fusiform Vertebrobasilar Giant Aneurysms: A Report on Periprocedural Course and Long-Term Follow-Up
  • Retrograde trans-anterior communicating artery rescue of unopened Pipeline Embolization Device with balloon dilation: complication management
  • Non-saccular vertebrobasilar aneurysms and dolichoectasia: a systematic literature review
  • Coiling of Large and Giant Aneurysms: Complications and Long-Term Results of 334 Cases
  • Treatment of recurrent intracranial aneurysms with the Pipeline Embolization Device
  • Last-Recorded P2Y12 Reaction Units Value Is Strongly Associated with Thromboembolic and Hemorrhagic Complications Occurring Up to 6 Months after Treatment in Patients with Cerebral Aneurysms Treated with the Pipeline Embolization Device
  • Endovascular Treatment of Intracranial Aneurysms With Flow Diverters: A Meta-Analysis
  • What's Coming Down the Pipe--And Should We Be Excited, Concerned, or Both?
  • Pre-procedure P2Y12 reaction units value predicts perioperative thromboembolic and hemorrhagic complications in patients with cerebral aneurysms treated with the Pipeline Embolization Device
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • MRI Findings in Children with Acute Flaccid Paralysis and Cranial Nerve Dysfunction Occurring during the 2014 Enterovirus D68 Outbreak
  • MRI Surrogates for Molecular Subgroups of Medulloblastoma
  • WEB-DL Endovascular Treatment of Wide-Neck Bifurcation Aneurysms: Short- and Midterm Results in a European Study
Show more EXPEDITED PUBLICATION

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2022 Distinguished Reviewers
  • Press Releases

Resources

  • Evidence-Based Medicine Level Guide
  • How to Participate in a Tweet Chat
  • AJNR Podcast Archive
  • Ideas for Publicizing Your Research
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Share Your Art in Perspectives
  • Get Peer Review Credit from Publons
  • Moderate a Tweet Chat

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal
  • Position Statements

© 2023 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire