Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Other Publications
    • ajnr

User menu

  • Subscribe
  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
LetterLETTER

Comment on “Reproducibility of Cerebrospinal Venous Blood Flow and Vessel Anatomy with the Use of Phase Contrast–Vastly Undersampled Isotropic Projection Reconstruction and Contrast-Enhanced MRA”

F. Sisini, A. Taibi, M. Gambaccini, E. Menegatti and P. Zamboni
American Journal of Neuroradiology March 2014, 35 (3) E3; DOI: https://doi.org/10.3174/ajnr.A3868
F. Sisini
aDepartment of Physics and Earth Sciences
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A. Taibi
aDepartment of Physics and Earth Sciences
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Gambaccini
aDepartment of Physics and Earth Sciences
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
E. Menegatti
bVascular Diseases Center University of Ferrara Cona, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
P. Zamboni
bVascular Diseases Center University of Ferrara Cona, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • References
  • PDF
Loading

In the introduction of the article “Reproducibility of Cerebrospinal Venous Blood Flow and Vessel Anatomy with the Use of Phase Contrast–Vastly Undersampled Isotropic Projection Reconstruction and Contrast-Enhanced MRA,”1 the authors pointed out that the Zamboni hypothesis, known as chronic cerebrospinal venous insufficiency (CCSVI), “has prompted much interest in the accuracy and reproducibility of cerebrospinal venous flow measurements, which have not yet been established.” The authors also stated that the diagnosis of CCSVI based on duplex (gray-scale and color Doppler) ultrasonography (US) has well-known limitations that can be overcome by using the MR imaging technique.

We agree with the authors about the need to investigate the cerebrospinal flow measurements, and we believe that MR imaging is a promising technique for this task. Nevertheless, the US technique is safe, allows real-time visualization of the moving structures, and is relatively inexpensive compared with MR imaging. Therefore, we are working to improve the US diagnostic methodology by using indexes based on the quantification of flow in the cerebrospinal veins to extend the current qualitative approach.2 Indeed, in our article, we proposed a simple model that, by assuming the conservation of mass criterion, allows us to work out the flow in the internal jugular veins (IJVs) and the collateral veins. One of our findings, also confirmed by Chambers et al,3 is that the flow increases as blood nears the heart.2,4 On the other hand, in Table 1 of their article, Schrauben et al1 reported that flow slightly decreases nearing the heart, by considering the left and right IJVs both as separated or as one. It is beyond the scope of this letter to compare the potential of the 2 modalities in assessing cerebrospinal flow. Moreover, the number of subjects used in both studies is too low to draw conclusive results. In conclusion, we believe that at present, the US potential is not limited to a qualitative assessment of the cerebrospinal veins, and we recommend always comparing the MR imaging results with the US ones. This comparison will improve the knowledge of the cerebrospinal flow that, as the authors said, is still incomplete.

REFERENCES

  1. 1.↵
    1. Schrauben EM,
    2. Johnson KM,
    3. Huston J,
    4. et al
    . Reproducibility of cerebrospinal venous blood flow and vessel anatomy with the use of phase contrast–vastly undersampled isotropic projection reconstruction and contrast-enhanced MRA. AJNR Am J Neuroradiol 2013 Nov 28. [Epub ahead of print]
  2. 2.↵
    1. Zamboni P,
    2. Sisini F,
    3. Menegatti E,
    4. et al
    . An ultrasound model to calculate the brain blood outflow through collateral vessels: a pilot study. BMC Neurol 2013;13:81
    CrossRefPubMed
  3. 3.↵
    1. Chambers B,
    2. Chambers J,
    3. Churilov L,
    4. et al
    . Internal jugular and vertebral vein volume flow in patients with clinically isolated syndrome or mild multiple sclerosis and healthy controls: results from a prospective sonographer-blinded study. Phlebology 2013 Sep 24. [Epub ahead of print]
  4. 4.↵
    1. Zamboni P,
    2. Menegatti E,
    3. Pomidori L,
    4. et al.
    , Does thoracic pump influence the cerebral venous return? J Appl Physiol 2012;112:904–10
    Abstract/FREE Full Text
  • © 2014 by American Journal of Neuroradiology
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 35 (3)
American Journal of Neuroradiology
Vol. 35, Issue 3
1 Mar 2014
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Comment on “Reproducibility of Cerebrospinal Venous Blood Flow and Vessel Anatomy with the Use of Phase Contrast–Vastly Undersampled Isotropic Projection Reconstruction and Contrast-Enhanced MRA”
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Comment on “Reproducibility of Cerebrospinal Venous Blood Flow and Vessel Anatomy with the Use of Phase Contrast–Vastly Undersampled Isotropic Projection Reconstruction and Contrast-Enhanced MRA”
F. Sisini, A. Taibi, M. Gambaccini, E. Menegatti, P. Zamboni
American Journal of Neuroradiology Mar 2014, 35 (3) E3; DOI: 10.3174/ajnr.A3868

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Comment on “Reproducibility of Cerebrospinal Venous Blood Flow and Vessel Anatomy with the Use of Phase Contrast–Vastly Undersampled Isotropic Projection Reconstruction and Contrast-Enhanced MRA”
F. Sisini, A. Taibi, M. Gambaccini, E. Menegatti, P. Zamboni
American Journal of Neuroradiology Mar 2014, 35 (3) E3; DOI: 10.3174/ajnr.A3868
del.icio.us logo Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • REFERENCES
  • Info & Metrics
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Reply:
  • The Complementary Role of CT Perfusion and Transcranial Doppler in the Assessment of Delayed Cerebral Ischemia after Aneurysmal SAH
  • Dilator-Dotter Technique for Acute Ischemic Stroke: Further Applications in the Vertebral Arteries
Show more Letters

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2021 Distinguished Reviewers
  • Press Releases

Resources

  • Evidence-Based Medicine Level Guide
  • How to Participate in a Tweet Chat
  • AJNR Podcast Archive
  • Ideas for Publicizing Your Research
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Share Your Art in Perspectives
  • Get Peer Review Credit from Publons
  • Moderate a Tweet Chat

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal
  • Position Statements

© 2022 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire