TY - JOUR T1 - Diagnostic Accuracy of Screening MR Imaging Using Unenhanced Axial CISS and Coronal T2WI for Detection of Small Internal Auditory Canal Lesions JF - American Journal of Neuroradiology JO - Am. J. Neuroradiol. SP - 2366 LP - 2370 DO - 10.3174/ajnr.A4041 VL - 35 IS - 12 AU - T.A. Abele AU - D.A. Besachio AU - E.P. Quigley AU - R.K. Gurgel AU - C. Shelton AU - H.R. Harnsberger AU - R.H. Wiggins III Y1 - 2014/12/01 UR - http://www.ajnr.org/content/35/12/2366.abstract N2 - BACKGROUND AND PURPOSE: While enhanced T1WI is considered the “gold standard” for detection of internal auditory canal pathology, unenhanced fluid-sensitive sequences have shown high sensitivity for lesion identification. Our purpose was to evaluate the diagnostic accuracy of an unenhanced MR imaging protocol using axial CISS and coronal T2WI for detection of small (10 mm or less) internal auditory canal lesions. MATERIALS AND METHODS: Twenty-three patients with small internal auditory canal lesions and 13 patients without lesions who had undergone MR imaging using the screening protocol and confirmatory gadolinium-enhanced thin section T1WI were identified. Two blinded neuroradiologists retrospectively evaluated all examinations using 1) only axial CISS, 2) only coronal T2WI, and 3) axial and coronal sequences together. Accuracy, specificity, sensitivity, and interobserver agreement were assessed. RESULTS: Median maximum lesion dimension was 4 mm (range, 2–10 mm). Accuracy, specificity, and sensitivity for axial CISS alone were 0.94, 0.96, and 0.91 for observer 1 and 0.94, 0.92, and 1.00 for observer 2. The data for the coronal T2WI sequence only were 0.94, 0.96, and 0.91 for observer 1, and 0.99, 1.00, and 0.96 for observer 2. Using axial and coronal sequences, the data were 0.97, 0.96, and 1.00 for observer 1, and 0.99, 0.98, and 1.00 for observer 2. κ coefficients were 0.84 for the axial sequence only, 0.90 for coronal only, and 0.91 for axial and coronal both. CONCLUSIONS: Screening noncontrast MR imaging using a combination of axial CISS and coronal T2WI sequences can detect small internal auditory canal lesions with 100% sensitivity and excellent interobserver agreement. IACinternal auditory canal ER -