@article {Oot131, author = {R Oot and P F New and F S Buonanno and I L Pykett and P Kistler and R Delapaz and K R Davis and J M Taveras and T J Brady}, title = {MR imaging of pituitary adenomas using a prototype resistive magnet: preliminary assessment.}, volume = {5}, number = {2}, pages = {131--137}, year = {1984}, publisher = {American Journal of Neuroradiology}, abstract = {Magnetic resonance (MR) images were obtained with a prototype resistive magnet system in 10 patients, all of whom had been shown to have pituitary tumors by enhanced high-resolution computed tomography (CT). Histologic verification was obtained in eight cases. Inversion-recovery (IR) T1-weighted images revealed the tumor in six of nine cases; saturation-recovery (SR) images with less T1 weighting identified seven of nine tumors; Carr-Purcell-Meiboom-Gill (CPMG) spin-echo T2-weighted images revealed two of four tumors. MR images failed to demonstrate three microadenomas: 5 X 5 X 8 mm, 6 X 6 X 6 mm, and one less than 5 mm in estimated size. In the last pretreatment study, CT had demonstrated a 13 mm maximum diameter adenoma. Repeat CT at the time of MR imaging also showed a partially empty sella and did not resolve the residual adenoma. The larger adenomas were identified readily by MR imaging, which, unlike CT, suggested old tumor hemorrhage in two cases, which was confirmed at surgery and histologic examination. MR and CT images were also compared for relative effectiveness in identifying important perisellar structures.}, issn = {0195-6108}, URL = {https://www.ajnr.org/content/5/2/131}, eprint = {https://www.ajnr.org/content/5/2/131.full.pdf}, journal = {American Journal of Neuroradiology} }