@article {Isoda1463, author = {H Isoda and R G Ramsey and Y Takehara and M Takahashi and M Kaneko}, title = {MR angiography of aneurysm models of various shapes and neck sizes.}, volume = {18}, number = {8}, pages = {1463--1472}, year = {1997}, publisher = {American Journal of Neuroradiology}, abstract = {PURPOSE To investigate the signal intensity of lateral and terminal saccular aneurysm models with differing neck sizes using three-dimensional time-of-flight (TOF) MR angiography with various imaging parameters.METHODS The study included four lateral and four terminal saccular aneurysm models with pulsatile flow. The height and fundus diameter were 10 mm; the neck diameters were 2.5 mm, 5 mm, 7.5 mm, and 10 mm, respectively. Each aneurysm model was examined with fast imaging with steady-state precession MR sequences with parameters of 20-140/7 (repetition time/echo time) and flip angles of 10 degrees to 30 degrees. Signal intensity was measured and compared among the models.RESULTS Three-dimensional TOF MR angiography with the shorter repetition time and/or larger flip angle showed weaker signal intensity in the aneurysm models. Stronger signal intensity was obtained in the terminal saccular aneurysm models and/or the models with a wider neck than in the lateral saccular aneurysm models and/or the models with a narrower neck. In some aneurysm models, longer repetition times produced greater signal intensity than that of background brain models, but not in aneurysms with narrow necks.CONCLUSION Noncontrast 3-D TOF MR angiography delineated terminal saccular aneurysms and/or aneurysms with wider necks and did not delineate lateral saccular aneurysms and/or aneurysms with narrower necks. Longer repetition times are recommended to allow the spins flowing into the aneurysms to recover.}, issn = {0195-6108}, URL = {https://www.ajnr.org/content/18/8/1463}, eprint = {https://www.ajnr.org/content/18/8/1463.full.pdf}, journal = {American Journal of Neuroradiology} }