TY - JOUR T1 - Surveillance of Unruptured Intracranial Saccular Aneurysms Using Noncontrast 3D-Black-Blood MRI: Comparison of 3D-TOF and Contrast-Enhanced MRA with 3D-DSA JF - American Journal of Neuroradiology JO - Am. J. Neuroradiol. SP - 960 LP - 966 DO - 10.3174/ajnr.A6080 VL - 40 IS - 6 AU - C. Zhu AU - X. Wang AU - L. Eisenmenger AU - B. Tian AU - Q. Liu AU - A.J. Degnan AU - C. Hess AU - D. Saloner AU - J. Lu Y1 - 2019/06/01 UR - http://www.ajnr.org/content/40/6/960.abstract N2 - BACKGROUND AND PURPOSE: Patients with unruptured intracranial aneurysms routinely undergo surveillance imaging to monitor growth. Angiography is the criterion standard for aneurysm diagnosis, but it is invasive. This study aimed to evaluate the accuracy and reproducibility of a 3D noncontrast black-blood MR imaging technique for unruptured intracranial aneurysm measurement in comparison with 3D-TOF and contrast-enhanced MRA, using 3D rotational angiography as a reference standard.MATERIALS AND METHODS: Sixty-four patients (57.3 ± 10.9 years of age, 41 women) with 68 saccular unruptured intracranial aneurysms were recruited. Patients underwent 3T MR imaging with 3D-TOF-MRA, 3D black-blood MR imaging, and contrast-enhanced MRA, and they underwent 3D rotational angiography within 2 weeks. The neck, width, and height of the unruptured intracranial aneurysms were measured by 2 radiologists independently on 3D rotational angiography and 3 MR imaging sequences. The accuracy and reproducibility were evaluated by Bland-Altman plots, the coefficient of variance, and the intraclass correlation coefficient.RESULTS: 3D black-blood MR imaging demonstrates the best agreement with DSA, with the smallest limits of agreement and measurement error (coefficients of variance range, 5.87%–7.04%). 3D-TOF-MRA had the largest limits of agreement and measurement error (coefficients of variance range, 12.73%–15.78%). The average coefficient of variance was 6.26% for 3D black-blood MR imaging, 7.03% for contrast-enhanced MRA, and 15.54% for TOF-MRA. No bias was found among 3 MR imaging sequences compared with 3D rotational angiography. All 3 MR imaging sequences had excellent interreader agreement (intraclass correlation coefficient, >0.95). 3D black-blood MR imaging performed the best for patients with intraluminal thrombus (n = 10).CONCLUSIONS: 3D black-blood MR imaging achieves better accuracy for aneurysm size measurements compared with 3D-TOF, using 3D rotational angiography as a criterion standard. This noncontrast technique is promising for surveillance of unruptured intracranial aneurysms.BBblack-bloodCEcontrast-enhancedCVcoefficient of variance3DRA3D rotational angiographyIAintracranial aneurysmICCintraclass correlation coefficientLOAlimit of agreementSPACEspatial and chemical-shift encoded excitationUIAunruptured intracranial aneurysm ER -