@article {Sirakov681, author = {A. Sirakov and K. Minkin and S. Sirakov}, title = {Intermixed Dimethyl-Sulfoxide{\textendash}Based Nonadhesive Liquid Embolic Agents Delivered Serially via the Same Microcatheter for Cerebral AVM Treatment}, volume = {41}, number = {4}, pages = {681--686}, year = {2020}, doi = {10.3174/ajnr.A6453}, publisher = {American Journal of Neuroradiology}, abstract = {BACKGROUND AND PURPOSE: Conventional nonadhesive liquid embolic agents currently are the criterion standard for endovascular embolization of cerebral AVMs. However, inadequate distal penetration into the nidus and unstable proximal plug formation are the major limitations of this approach and of the currently available embolic materials. The aim of this study was to evaluate the hypothetic efficacy of combining liquid embolic agents with different properties and viscosities for use in endovascular embolization of cerebral AVMs.MATERIALS AND METHODS: From March 2018 to March 2019, sixteen patients with cerebral AVMs (12 women, 4 men; age range, 33{\textendash}61 years) underwent endovascular embolization with combined liquid embolic agents delivered serially via a single microcatheter. The procedure consists of initial embolization with PHIL 30\%, followed by Menox 18 through the same microcatheter. According to the Spetzler-Martin scale, 11 (68.75\%) AVMs were grades I{\textendash}II, 4 (25\%) were grade III, and 1 (6.25\%) was grade IV. Angiographic, technical, and clinical outcomes were analyzed independently.RESULTS: Combined PHIL and Menox embolization through the same microcatheter via 21 pedicles was performed in these 16 patients. Once the length of the reflux reached approximately 2 cm, PHIL 30\% was switched to Menox 18. Antegrade flow and distal penetration of the serially applied liquid embolic agents were observed in all 16 cases. The ability to completely control the flow of the materials and avoid any dangerous proximal reflux was noted in all performed embolizations. The estimated average size reduction of the treated AVMs was 85\%, ranging from 50\% to 100\%. Complete embolization was achieved in 10/16 or 62.5\% of the cases. There was no procedure-related complication during or after the embolization. No mortality or postprocedural clinical worsening was seen. Clinical success and complete obliteration were confirmed with at least 1 follow-up angiography in 10/16 patients.CONCLUSIONS: Serial delivery of nonadhesive liquid embolic agents via the same microcatheter was safe and effective in our study and may be a potential technique for routine AVM treatment. However, further investigations are required to validate the safety and the efficacy of the method.DMSOdimethyl-sulfoxideEVOHethylene-vinyl alcohol copolymerLEAliquid embolic agent}, issn = {0195-6108}, URL = {https://www.ajnr.org/content/41/4/681}, eprint = {https://www.ajnr.org/content/41/4/681.full.pdf}, journal = {American Journal of Neuroradiology} }