Hemodynamic parameters in an acute and a chronic swine rete AVM model

Acute ModelChronic ModelP Value
Age (months)3.9 ± 3.212.4 ± 0.5<.0001
Weight (kg)46.9 ± 22.7213.7 ± 25.9<.001
Pressure grandient (mm Hg)15.4 ± 1.423.7 ± 12.0.085
Rete outflow (mL/min)32.5 ± 17.57139.9 ± 100.29.030
Rete length (pixel)401.3 ± 65.2593.1 ± 39.9<.001