Table 9:

Initial outcome of endovascular procedure: operator self assessment

Randomized TreatmentAbsolute Difference
HydrogelBare Platinum
No.%No.%(95% CI)
Total no. patients randomized249250
    No coiling done52.020.8
    Consent withdrawn10.400
Degree of occlusion (operator opinion)*
    Complete115/24347.3118/24847.6−0.3% (−9.0% to +8.5%)
    Nearly complete76/24331.394/24837.9−6.6% (−14.9% to +1.8%)
    Incomplete52/24321.436/24814.5+6.9% (+0.1% to 13.7%)
  • Note:—CI indicates confidence interval.

  • * χ2 test for trend, P = .3.