Table 4:

Inadequate block and false-negative rate of diagnostic selective nerve root block

Inadequate BlockResults of DSNRBFalse-Negative RatePValue (Fisher Exact Test)
False-NegativeTrue-Positive
Present10283% (10/12).002
Absent102529% (10/35)
  • Note:—DSNRB indicates diagnostic selective nerve root block.