Table 3:

Results of the analysis of ISSON width in 19 patients with CSHa,b

Patient No.ISSON WidthISSON Width (Gross Visual Inspection)
Position 1Position 2Position 3Position 4
–/NMM–/NMM–/NMM–/NMM–/N
1N1.1000
2N.A.0.60.60.7
3N1.2N1.10.70.8
40000
50000
60000
70000
80000
9N1.6N0.90.70
10N1.20.60.70
110.8000.8
12N1.1000
130000
14N1.2000
150.8000
160.7000
170000
18N1.4N1.20.70
190000
Mean0.60.20.20.1
SD0.60.40.30.3
Sensitivity61%84%100%100%100%
CI (95%)36%–83%60%–97%85%–100%85%–100%85%–100%
ICCc0.9080.8590.8620.824
κc1
  • a Measurements were obtained in 4 intraorbital positions approximately 3, 6, 10, and 20 mm behind the eyeball. Specificity was 97% each.

  • b –indicates decreased (<1.0 mm, [position 1]; <0.9 mm, [positions 2–4]). Regarding gross visual inspection,–corresponds to a reduction or absence of CSF in the ISSON.

  • c ICC and κ values were computed for results of 3 readers.