TABLE 1:

Diagnostic Discrimination for MR Sialography and Digital Subtraction Sialography for the Three Most Frequent Diagnoses

Performance MeasureChronic SialadenitisAcute SialadenitisSialolithiasis
MRSDSSMRSDSSMRSDSS
Sensitivity (%)70961001008090
Specificity (%)981001001009898
PPV (%)951001001008990
NPV (%)86981001009798
  • Note.—MRS indicates MR sialography; DSS, digital subtraction sialography; PPV, positive predictive value; NPV, negative predictive value.