TABLE 3:

Left-right symmetry of qualitative findings and measurements

FindingGanglionV2V3
Visualized*P = 1.0, agree = 0.92P = .51, agree = 0.86P = .51, agree = 0.86
Morphology and enhancement*P = .37, agree = 0.92P = .16, agree = 0.75P = .39, agree = 0.91
Plexus completely surrounding V2 or seen on both sides of V3NAP = 1.0, agree = 0.49P = 1.0, agree = 0.62
Diameter of nerve and plexus (mm)NAP = .36, diff = 0.07P = .23, diff = 0.16
Diameter of nerve and alone (mm)NAP = .12, diff = 0.13P = .57, diff = 0.05
  • Note.—Reported P values for significant different between left and right from McNemar’s test for qualitative findings (indicated by asterisks) and paired t tests for measurements. Agree indicates proportion concordant (sides in agreement/total); diff, mean difference in millimeters (right-left).