Results of the observer study rating the visibility without and with MAR

Without MARκWith MARκ
Overall Agreement, %Score 1 Agreement, %Score ≥2 Agreement, %Overall Agreement, %Score 1 Agreement, %Score ≥2 Agreement, %
Stent visibility
    P < .05
    OR = 7.87756120.667624400.64
    CI = 1.6–38.8
Vessel visibility
    P < .05
    OR = 8.77652120.647220400.58
    CI = 1.7–45.2
Relationship
    P < .05
    OR = 9.08160120.727020360.56
    CI = 1.7–47.0
Overall Agreement, %Yes Agreement, %No Agreement, %κOverall Agreement, %Yes Agreement, %No Agreement, %κ
Obscuring beyond
        coil mass?
    (P < .0001
    OR = 224.0735640.47784640.57
    CI = 12.8–3926.0)
Overall Agreement, %Without MAR Agreement, %With MAR Agreement, %κ
Overall best visibility940920.89
  • Note:—The rows “stent visibility,” “vessel visibility,” and “relationship” show the summarized results to the 3-point scale questions. Given are the percent overall agreement (ie, the number of cases that all reviewers agreed in total, calculated using the Fleiss method), the percent agreement for a score 1 (ie, the number of cases all reviewers agreed on giving a score of 1), and the percent agreement for a score ≥2 (ie, the number of cases all reviewers agreed on giving a score of 2 or 3). Similarly, agreements for the binary questions are indicated. For each observer question, the κ values, P value, odds ratio (OR), and 95% confidence intervals (CI) are given when applicable. OR represents the improvement of classification of 1 to ≥2 with MAR.