Sensitivity, specificity, and cutoff values of best models for classificationa

ModelSensitivitySpecificityCutoff ValuesAUC95% CI
TP vs PsP + mixed
    CP0.710.900.070.840.72–0.96
    FA0.710.750.130.780.64–0.93
    CL0.710.750.040.720.56–0.88
    rCBVmax0.620.804.060.770.63–0.92
    FA + CL + rCBVmax0.760.950.550.900.81–1.00
PsP vs TP + mixed
    CP0.571.000.070.740.59–0.89
    FA0.401.000.130.700.52–0.87
    rCBVmax0.820.632.770.730.54–0.91
    FA + rCBVmax0.790.750.770.810.66–0.95
TP vs mixed
    CP0.710.830.070.830.69–0.97
    FA0.710.750.130.760.56–0.95
    CL0.710.750.040.690.49–0.90
    rCBVmax0.620.834.060.740.57–0.92
    FA + CL + rCBVmax0.761.000.650.900.78–1.00
PsP vs mixed
    MDmin0.500.880.980.620.34–0.89
  • Note:—MDmin indicates minimum MD.

  • a The unit for MD is ×10−3mm2/s.