Table 2:

Aneurysm characteristics

Aneurysm CharacteristicsPED/CoilsPED AloneP Valuea
No. of aneurysms109797
No. of patients104689
Aneurysm size (mm)b<.0001
    Mean13.6 ± 7.810.3 ± 7.6
    Median, range12; 1.6–45.08; 1.0–55.0
Aneurysm neck (mm).017
    Mean6.4 ± 3.06.2 ± 5.1
    Median, range6; 0.8–16.05; 0.9–53.0
Aneurysm shape (No., %).3366
    Fusiform13 (11.9%)103 (12.9%)
    Saccular85 (78.0%)604 (75.8%)
    Dissecting3 (2.8%)51 (6.4%)
    Other8 (7.3%)39 (4.9%)
Aneurysm location (No., %)<.0001
    Internal carotid artery70 (64.2%)614 (77.0%)
    Middle cerebral artery8 (7.3%)35 (4.4%)
    Posterior cerebral artery0 (0%)15 (1.9%)
    Basilar artery16 (14.7%)28 (3.5%)
    Other15 (13.8%)105 (13.2%)
Aneurysm ruptured at initial presentation (No., %)13 (11.9%)63 (7.9%).155
Multiple PEDs usedc (No., %)34 (31.2%)274 (34.5%).499
  • a P values for aneurysm size and neck size were calculated with Wilcoxon rank sum tests. P values for categoric variables were calculated with χ2 tests.

  • b Of the 797 aneurysms treated with PEDs alone, size data were not available for 8 aneurysms. Of the 109 aneurysms treated with PED/coil, size data were not available for 2 aneurysms.

  • c Of the 797 aneurysms treated with PEDs alone, data regarding the number of PEDs used were not reported for 2 aneurysms.