Table 6:

Radiation dose and scan length by age

Younger Than 1 Year1 Year to Younger Than 5 Years5 Years to Younger Than 10 Years10 Years to Younger Than 18 YearsAll Children
No. of children7422750126
Mean original z-length (cm)13.9115.9319.9424.7720.18
Mean modified z-length (cm)6.638.0410.3213.0410.43
% Decrease in mean z-length for modified CT5250484748
Mean effective dose for original CT (mSv)0.860.630.731.531.02
Mean effective dose for modified CT (mSv)0.410.320.380.830.54
% Decrease in mean effective dose for modified CT5349484647