Table 2:

Results of postoperative DECT image analysis with interreader concordance and subsequent consensus

Reader 1Reader 2Interreader ConcordanceConsensus
Presence of parenchymal hyperdensity
    Yes53/85 (62.4%)53/85 (62.4%)κ = 0.95; 95% CI, 0.882–1.00054/85 (63.5%)
    No32/85 (37.6%)32/85 (37.6%)31/85 (36.5%)
Hyperdensity location
    DWM26/53 (49.1%)31/53 (58.5%)κ = 0.745; 95% CI, 0.588–0.90329/54 (53.7%)
    DWM+cortical/subcortical21/53 (39.6%)16/53 (30.2%)18/54 (33.3%)
    Cortical/subcortical6/53 (11.3%)6/53 (11.3%)7/54 (13.0%)
Hyperdensity homogeneity
    Homogeneous29/53 (54.7%)31/53 (58.5%)κ = 0.799; 95% CI, 0.632–0.96630/54 (55.6%)
    Inhomogeneous24/53 (45.3%)22/53 (41.5%)24/54 (44.4%)
Mean maximum attenuation (HU)100 (median 77, range 45–701)103 (median 76, range 47–789)P = .99974 (range, 47–745)
Presence of iodine extravasation
    Yes53/85 (62.4%)53/85 (62.4%)κ = 0.976; 95% CI, 0.929–1.00054/85 (63.5%)
    No32/85 (37.6%)32/85 (37.6%)31/85 (36.5%)
Mean maximum iodine concentration (mg/dL)3.0 (median,1.8; range 0.5–28.4)2.9 (median, 1.6; range 0.6–27.7)P = .9261.8 (range, 0.5–28.1)
Hemorrhage on VNC images
    Yes5/85 (5.9%)5/85 (5.9%)κ = 1.000; 95% CI, 1.000–1.0005/85 (5.9%)
    No80/85 (94.1%)80/85 (94.1%)80/85 (94.1%)
  • Note:—DWM indicates deep white matter.