Table 3:

Optimal threshold, sensitivity, specificity, overall accuracy, and ROC area imaging variables that were significant with univariate analysis

VariableThresholdSpecificitySensitivityOverall AccuracyROC Area
Base infarct volume (mL)24.176.5%63.6%70.1%0.717
Final infarct volume (mL)4582.4%59.1%70.7%0.706
Volume of ATD>6 s (mL)27.7788.2%63.6%75.9%0.777
Volume of ATD2–6 s (mL)38.2882.4%81.8%82.1%0.906
rCBF158.8%90.9%74.9%0.709
rCBV2–6 s1.688.2%81.8%85.0%0.900
PCIa61.7088.2%100.0%94.1%0.973
  • a PCI = Volume of ATD2–6 seconds × rCBV2–6 seconds.