Resolution Improvements inin Vivo1H NMR Spectra with Increased Magnetic Field Strength

https://doi.org/10.1006/jmre.1998.1542Get rights and content

Abstract

The measurement of cerebral metabolites using highly homologous localization techniques and similar shimming methods was performed in the human brain at 1.5 and 4 T as well as in the dog and rat brain at 9.4 T. In rat brain, improved resolution was achieved by shimming all first- and second-order shim coils using a fully adiabatic FASTMAP sequence. The spectra showed a clear improvement in spectral resolution for all metabolite resonances with increased field strength. Changes in cerebral glutamine content were clearly observed at 4 T compared to 1.5 T in patients with hepatic encephalopathy. At 9.4 T, glutamine H4 at 2.46 ppm was fully resolved from glutamate H4 at 2.37 ppm, as was the potential resonance from γ-amino-butyric acid at 2.30 ppm and N-acetyl-aspartyl-glutamate at 2.05 ppm. Singlet linewidths were found to be as low as 6 Hz (0.015 ppm) at 9.4 T, indicating a substantial decrease in ppm linewidth with field strength. Furthermore, the methylene peak of creatine was partially resolved from phosphocreatine, indicating a close to 1:1 relationship in gray matter. We conclude that increasing the magnetic field strength increases spectral resolution also for1H NMR, which can lead to more than linear sensitivity gains.

References (40)

  • J. Hu et al.

    J. Magn. Reson. B

    (1995)
  • P.C.M. van Zijl et al.

    J. Magn. Reson. A

    (1994)
  • J. Tropp et al.

    J. Magn. Reson.

    (1989)
  • R. Gruetter et al.

    J. Magn. Reson.

    (1992)
  • R.A. de Graaf et al.

    J. Magn. Reson. B

    (1996)
  • C.T.W. Moonen et al.

    J. Magn. Reson.

    (1990)
  • M. Terpstra et al.

    J. Magn. Reson.

    (1998)
  • L.L. Cheng et al.

    Proc. Natl. Acad. Sci. USA

    (1997)
  • T.G. Reese et al.

    J. Magn. Reson. Imaging

    (1995)
  • E. Schneider et al.

    Magn. Reson. Med.

    (1991)
  • S. Kanayama et al.

    Magn. Reson. Med.

    (1996)
  • F.A. Jaffer et al.

    Magn. Reson. Med.

    (1996)
  • P. Webb et al.

    Magn. Reson. Med.

    (1991)
  • M.G. Prammer et al.

    J. Magn. Reson.

    (1988)
  • R. Gruetter

    Magn. Reson. Med

    (1993)
  • R. Gruetter, K. Ugurbil, In “3rd Annual Meeting ISMRM,...
  • M.D. Boska et al.

    Magn. Reson. Med

    (1990)
  • S. Weisdorf, K. Hendrich, H. Merkle, K. Ugurbil, M. Garwood, In “Soc. Magn. Reson. Med,...
  • N. Beckman et al.

    Magn. Reson. Med.

    (1990)
  • Cited by (172)

    • MR Perfusion and MR Spectroscopy of Brain Neoplasms

      2019, Radiologic Clinics of North America
      Citation Excerpt :

      Besides the metabolite concentration in vivo, the signal to noise ratio is a key factor, which is affected by magnetic field strength and homogeneity and the radiofrequency coil. Additional factors include the specific pulse sequence and imaging parameters, which affect the spectral resolution and therefore determine the number of metabolites that are gleaned.42,43 Many different molecules have been evaluated for their clinical utility.

    View all citing articles on Scopus
    View full text