Balloon-assisted coiling through a 5-French system

  • Interventional Neuroradiology
  • Published:
Neuroradiology Aims and scope Submit manuscript

Abstract

Introduction

We present a catheter technique that utilizes a 5F system for the purpose of balloon-assisted coiling in the setting of intracranial aneurysms.

Methods

A standard 5F short sheath is placed in the common femoral artery, and a 5F diagnostic catheter is placed through the sheath and used for selective vessel angiography. When endovascular intervention is pursued, the diagnostic catheter is placed in the appropriate vessel and systemic heparinization is ensured. Over an exchange length wire, the 5F vertebral catheter and 5F short sheath are exchanged for a 5F Shuttle (Cook) sheath. We then routinely place a 10, 14 or 18 microcatheter over an appropriately gauged microguidewire into the aneurysm. As needed, balloon catheters are then placed across the neck of the aneurysm for remodeling purposes. During the course of the procedure, control angiography is performed through the Shuttle sheath. Following the placement of coils, the microcatheter and balloon catheter are removed and a final biplane image is obtained via the 5F Shuttle sheath.

Results

This technique has been employed in 15 patients who required balloon-assisted coiling of an intracranial aneurysm. There were no technical difficulties or arterial access site complications from the procedures. Catheter mobility and torque were not affected, nor was the quality of our imaging.

Conclusion

We conclude that this small-diameter system provides ample “room” for catheter placement and interventional treatment while reducing the known risks of postprocedural complications. Angiographic images remain excellent and are comparable to those obtained by larger catheters.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1

Similar content being viewed by others

References

  1. Lilly MP, Reichman W, Sarazen AA Jr et al (1990) Anatomic and clinical factors associated with complications of transfemoral arteriography. Ann Vasc Surg 4:264–269

    Article  PubMed  CAS  Google Scholar 

  2. Kohli RS, Vetrovec GW, Lewis SA et al (1989) Study of the performance of 5 French and 7 French catheters in coronary angiography: a functional comparison. Cathet Cardiovasc Diagn 18:131–135

    Article  PubMed  CAS  Google Scholar 

  3. Morgan R, Belli A-M (2003) Current treatment methods for postcatheterization pseudoaneurysms. J Vasc Interv Radiol 14:697–710

    PubMed  Google Scholar 

  4. Luzardo GD, Ross IB, Gal G (2006) Balloon-assisted coiling through a single 6F guiding catheter. AJNR Am J Neuroradiol 27:190–191

    PubMed  CAS  Google Scholar 

Download references

Conflict of interest statement

We declare that we have no conflict of interest.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Harry J. Cloft.

Rights and permissions

Reprints and permissions

About this article

Cite this article

White, J.B., Layton, K.F., Kallmes, D.F. et al. Balloon-assisted coiling through a 5-French system. Neuroradiology 49, 157–159 (2007). https://doi.org/10.1007/s00234-006-0163-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00234-006-0163-3

Keywords

Navigation