Abstract
The purpose of this study was to evaluate the usefulness of a tool that we developed to simulate performance of visceral angiography to train beginners in the field of splanchnic angiography. Seven residents and two fellows who were rotating within the Division of Interventional Radiology at our institution between June and August 2008 participated in the evaluation of this tool. They had no experience in performing visceral angiography as an operator. Time for selection of arterial branches arising from the celiac axis on the model was measured before and after training. After such training, the participants performed actual visceral angiography as an operator with instructors beside them. Success of the trainees in selecting visceral arterial branches was evaluated in these real-life cases. In the first test using the model, seven of nine trainees (77.8%) succeeded in selecting all required arteries, while the remaining two failed to select all required arteries. After training using the model, all trainees succeeded in selecting all required arteries just before the actual angiographic study. In the actual angiography, the catheter was successfully inserted from the femoral artery and advanced to the superior mesenteric, celiac, splenic, common hepatic, gastroduodenal, and right and left hepatic arteries by all trainees with only two exceptions. In conclusion, this tool is helpful for training beginners in visceral angiographic procedures.
Similar content being viewed by others
References
Patal AA, Gould DA (2006) Simulators in interventional radiology training and evaluation: a paradigm shift is on the horizon. J Vasc Interv Radiol 17:S163–S173
Berry M, Hellstrom M, Gothlin J, Reznick R, Lonn L (2008) Endovascular training with animals versus virtual reality systems: an economic analysis. J Vasc Interv Radiol 19:233–238
Rigattieri S, Ferraiuolo G, Loschiavo P (2007) Transradial access in a cath lab with moderate procedual volume: a single operator’s experience. Minerva Cardioangiol 55:303–309
Rieker O, Duber C, Schmiedt W, von Zitzewitz, Schweden F, Thelen M (1996) Prospective comparison of CT angiography of the legs with intraarterial digital subtraction angiography. AJR Am J Roentgenol 166:269–276
Guven A, Acunas B (2004) Multidetector computed tomography angiography of the abdomen. Eur J Radiol 52:44–55
Hertz SM, Baum RA, Owen RS, Holland GA, Logan DR, Carpenter JP (1993) Comparison of magnetic resonance angiography and contrast arteriography in peripheral arterial stenosis. Am J Surg 166:112–116
Michaely HJ, Dietrich O, Nael K, Weckbach S, Reiser MF, Schoenberg SO (2006) MRA of abdominal vessels: technical advances. Eur Radiol 16:1637–1650
Michaely HJ, Attenberger UI, Kramer H, Nael K, Reiser MF, Schoenberg SO (2007) Abdominal and pelvic MR angiography. Magn Reson Imaging Clin N Am 15:301–314
Wang F, Duratti L, Samur E, Spaelter U, Bleuler H (2007) A computer-based real-time simulation of interventional radiology. Conf Proc IEEE Eng Med Biol Soc 2007:1740–1742
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Yamagami, T., Osuga, K., Yoshimatsu, R. et al. Development of a Portable Training Tool for Simulating Visceral Angiographic Procedures for Beginners. Cardiovasc Intervent Radiol 32, 412–416 (2009). https://doi.org/10.1007/s00270-009-9519-5
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00270-009-9519-5