Abstract
Arterial restenosis following stent deployment may be influenced by the local flow environment within and around the stent. We have used computational fluid dynamics to investigate the flow field in the vicinity of model stents positioned within straight and curved vessels. Our simulations have revealed the presence of flow separation and recirculation immediately downstream of stents. In steady flow within straight vessels, the extent of flow disturbance downstream of the stent increases with both Reynolds number and stent wire thickness but is relatively insensitive to stent interwire spacing. In curved vessels, flow disturbance downstream of the stent occurs along both the inner and outer vessel walls with the extent of disturbance dependent on the angle of vessel curvature. In pulsatile flow, the regions of flow disturbance periodically increase and decrease in size. Non-Newtonian fluid properties lead to a modest reduction in flow disturbance downstream of the stent. In more realistic stent geometries such as stents modeled as spirals or as intertwined rings, the nature of stent-induced flow disturbance is exquisitely sensitive to stent design. These results provide an understanding of the flow physics in the vicinity of stents and suggest strategies for stent design optimization to minimize flow disturbance.
Similar content being viewed by others
References
Albuquerque, M. L. C., C. M. Waters, U. Savla, H. W. Schnaper, and A. S. Flozak. Shear stress enhances human endothelial cell wound closure in vitro. Am. J. Physiol. 279:H293–H302, 2000.
Armaly, B. F., F. Durst, J. C. F. Pereira, and B. Schonung. Experimental and theoretical investigation of backward-facing step flow. J. Fluid Mech. 127:473–496, 1983.
Asakura, T., and T. Karino. Flow patterns and spatial distribution of atherosclerotic lesions in human coronary arteries. Circ. Res. 66:1045–1066, 1990.
Barakat, A. I. Responsiveness of vascular endothelium to shear stress: Potential role of ion channels and cellular cytoskeleton. Int. J. Mol. Med. 4:323–332, 1999.
Barakat, A. I., T. Karino, and C. K. Colton. Microcinematographic studies of the flow field in the excised rabbit aorta. Biorheology 34:195–221, 1997.
Berger, S. A., L. Talbot, and L.-S. Yao. Flow in curved pipes. Annu. Rev. Fluid Mech. 15:461–512, 1983.
Berry, J. L., A. Santamarina, J. E. Moore, Jr., S. Roychowdhury, and W. D. Routh. Experimental and computational flow evaluation of coronary stent. Ann. Biomed. Eng. 28:386–398, 2000.
Caro, C. G. The Mechanics of the Circulation. Oxford: Oxford University Press, 1978.
Carter, A. J., D. Scott, J. R. Laird, L. Bailey, J. A. Kovach, T. G. Hoopes, K. Pierce, K. Heath, K. Hess, A. Farb, and R. Virmani. Progressive vascular remodeling and reduced neointimal formation after placement of a thermoelastic self-expanding Nitinol stent in an experimental model. Catheter. Cardiovasc. Diag. 44:193–201, 1998.
Chandran, K. B. Flow dynamics in the human aorta. J. Biomech. Eng. 115:611–616, 1993.
Chappell, D. C., S. E. Varner, R. M. Nerem, R. M. Medford, and R. W. Alexander. Oscillatory shear stress stimulates adhesion molecule expression in cultured human endothelium. Circ. Res. 82:532–539, 1998.
Cheer, A. Y., H. A. Dwyer, A. I. Barakat, E. Sy, and M. Bice. Computational study of the effect of geometric and flow parameters on the steady flow field at the rabbit aorto-celiac bifurcation. Biorheology 35:415–435, 1998.
Chien, S., S. Usami, M. Taylor, J. L. Lundberg, and M. I. Gergersem. Effects of hematocrit and plasma proteins on human blood rheology at low shear rates. J. Appl. Physiol. 21:81–87, 1966.
Davies, P. F. Flow-mediated endothelial mechanotransduction. Physiol. Rev. 75:519–560, 1995.
Depaola, N., M. A. Gimbrone, Jr., P. F. Davies, and C. F. Dewey, Jr. Vascular endothelium responds to fluid shear stress gradients. Arterioscler. Thromb. 12:1254–1257, 1992.
Emanuelsson, H., W. J. van des Giessen, and P. W. Serruys. Benestent II: Back to the future. J. Intervent. Cardiol. 7:587–592, 1994.
Ettenson, D. S., E. W. Y. Koo, J. L. Januzzi, and E. R. Edelman. Endothelial heparan sulfate is necessary but not sufficient for control of vascular smooth muscle cell growth. J. Cell. Physiol. 184:93–100, 2000.
Frank, A. O., P. W. Walsh, and J. E. Moore, Jr. Computational fluid dynamics and stent design. Artif. Organs 26:614–621, 2002.
Helmlinger, G., B. C. Berk, and R. M. Nerem. Calcium responses of endothelial cell monolayers subjected to pulsatile and steady laminar flow differ. Am. J. Physiol. 269:C367-C375, 1995.
Kastrati, A., J. Mehilli, J. Dirschinger, F. Dotzer, H. Schuhlen, F.-J. Neumann, M. Fleckenstein, C. Pfafferott, M. Seyfarth, and A. Schomig. Intracoronary stenting and angiographic results—Strut thickness effect on restenosis outcome (ISAR-STEREO) trial. Circulation 103:2816–2821, 2001.
Kastrati, A., J. Mehilli, J. Dirschinger, J. Pache, K. Ulm, H. Schuhlen, M. Seyfarth, C. Schmitt, R. Blasini, F.-J. Neumann, and A. Schomig. Restenosis after coronary placement of various stent types. Am. J. Cardiol. 87:34–39, 2001.
Komatsu, R., M. Ueda, T. Naruko, A. Kojima, and A. T. Becker. Neointimal tissue response at sites of coronary stenting in humans—Macroscopic, histological, and immunohistochemical analyses. Circulation 98:224–233, 1998.
Ku, D. N., D. P. Giddens, C. K. Zarins, and S. Glagov. Pulsatile flow and atherosclerosis in the human carotid bifurcation: Positive correlation between plaque location and low and oscillating shear stress. Arteriosclerosis 5:293–302, 1985.
Lum, R. M., L. M. Wiley, and A. I. Barakat. Influence of different forms of shear stress on vascular endothelial TGF-β1 mRNA expression. Int. J. Mol. Med. 5:635–641, 2000.
Moore, J. E., C. Xu, S. Glagov, C. K. Zarins, and D. N. Ku. Fluid wall shear stress measurements in a model of the human abdominal aorta: Oscillatory behavior and the relationship to atherosclerosis. Atherosclerosis 110:225–240, 1994.
Morice, M.-C., P. W. Serruys, J. E. Sousa, J. Fajadet, E. B. Hayashi, M. Perin, A. Colombo, G. Schuler, P. Barragan, G. Guagliumi, F. Molnar, and R. Falotico. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N. Engl. J. Med. 346:1773–1780, 2002.
Moses, J. W., M. B. Leon, J. J. Popma, P. J. Fitzgerald, D. R. Holmes, C. O’Shaughnessy, R. P. Caputo, D. J. Keriakes, D. O. Williams, P. S. Teirstein, J. L. Jaeger, and R. E. Kuntz. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N. Engl. J. Med. 349:1315–1323, 2003.
Natarajan, S., and M. R. Mokhtarzadeh-Dehghan. A numerical and experimental study of periodic flow in a model of a corrugated vessel with application to stented arteries. Med. Eng. Phys. 22:555–566, 2000.
Nerem, R. M. Vascular fluid mechanics, the arterial wall, and atherosclerosis. J. Biomech. Eng. 114:274–282, 1992.
Pedley, T. J. The Fluid Mechanics of Large Blood Vessels. Cambridge, UK: Cambridge University Press, 1980.
Resnick, N., and M. A. Gimbrone, M. A., Jr. Hemodynamic forces are complex regulators of endothelial gene expression. FASEB J. 9:874–882, 1995.
Rhee, K., and J. M. Tarbell. A study of the wall shear rate distribution near the end-to-end anastomosis of a rigid graft and compliant artery. J. Biomech. 27:329–338, 1994.
Rogers, C., and E. R. Edelman. Endovascular stent design dictates experimental restenosis and thrombosis. Circulation 91:2995–3001, 1995.
Rogers, C., S. Parikh, P. Seifert, and E. R. Edelman. Endogenous cell seeding—Remnant endothelium after stenting enhances vascular repair. Circulation 94:2909–2914, 1996.
Schatz, R. A. A view of vascular stents. Circulation 79:445–457, 1989.
Suvatne, J., A. I. Barakat, and M. E. O’Donnell. Shear stress regulation of endothelial Na-K-Cl co-transport expression: Dependence on K+ and Cl− channels. Am. J. Physiol. 280:C216–C227, 2001.
Wentzel, J. J., R. Krams, C. H. Schuurbiers, J. A. Oomen, J. Kloet, W. J. van der Giessen, P. W. Serruys, and C. J. Slager. Relationship between neointimal thickness and shear stress after Wallstent implantation in human coronary arteries. Circulation 103:1740–1745, 2001.
Wentzel, J. J., D. M. Whelan, W. J. van der Giessen, H. M. M. van Beusekom, I. Andhyiswara, P. W. Serruys, C. J. Slager, and R. Krams. Coronary stent implantation changes 3-D vessel geometry and 3-D shear stress distribution. J. Biomech. 33:1287–1295, 2000.
White, C. R., M. Haidekker, X. P. Bao, and J. A. Frangos. Temporal gradients in shear, but not spatial gradients, stimulate endothelial cell proliferation. Circulation 103:2508–2513, 2001.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Seo, T., Schachter, L.G. & Barakat, A.I. Computational Study of Fluid Mechanical Disturbance Induced by Endovascular Stents. Ann Biomed Eng 33, 444–456 (2005). https://doi.org/10.1007/s10439-005-2499-y
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s10439-005-2499-y