Skip to main content
Log in

Intracranial Stents Being Modeled as a Porous Medium: Flow Simulation in Stented Cerebral Aneurysms

  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

Abstract

Intracranial aneurysms may be treated by flow diverters, alternatively to stents and coils combination. Numerical simulation allows the assessment of the complex nature of aneurismal flow. Endovascular devices present a rather dense and fine strut network, increasing the complexity of the meshing. We propose an alternative strategy, which is based on the modeling of the device as a porous medium. Two patient-specific aneurysm data sets were reconstructed using conventional clinical setups. The aneurysms selection was done so that intra-aneurismal flow was shear driven in one and inertia driven in the other. Stents and their porous medium analog were positioned at the aneurysm neck. Physiological flow and standard boundary conditions were applied. The comparison between both approaches was done by analyzing the velocity, vorticity, and shear rate magnitudes inside the aneurysm as well as the wall shear stress (WSS) at the aneurysm surface. Simulations without device were also computed. The average flow reduction reaches 76 and 41% for the shear and inertia driven flow models, respectively. When comparing the two approaches, results show a remarkable similarity in the flow patterns and magnitude. WSS, iso-velocity surfaces and velocity on a trans-sectional plane are in fairly good agreement. The root mean squared error on the investigated parameters reaches 20% for aneurysm velocity, 30.6% for aneurysm shear rate, and 47.4% for aneurysm vorticity. It reaches 20.6% for WSS computed on the aneurysm surface. The advantages of this approach reside in its facility to implement and in the gain in computational time. Results predicted by the porous medium approach compare well with the real stent geometry model and allow predicting the main effects of the device on intra-aneurismal flow, facilitating thus the analysis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9

Similar content being viewed by others

References

  1. Aenis, M., et al. Modeling of flow in a straight stented and nonstented side wall aneurysm model. J. Biomech. Eng. 119(2):206–212, 1997.

    Article  CAS  PubMed  Google Scholar 

  2. Ahlhelm, F., et al. Treatment of wide-necked intracranial aneurysms with a novel self-expanding two-zonal endovascular stent device. Neuroradiology 49(12):1023–1028, 2007.

    Article  PubMed  Google Scholar 

  3. Ahn, J. Y., et al. Endovascular treatment of intracranial vertebral artery dissections with stent placement or stent-assisted coiling. AJNR Am. J. Neuroradiol. 27(7):1514–1520, 2006.

    CAS  PubMed  Google Scholar 

  4. Benndorf, G., et al. Treatment of a ruptured dissecting vertebral artery aneurysm with double stent placement: case report. AJNR Am. J. Neuroradiol. 22(10):1844–1848, 2001.

    CAS  PubMed  Google Scholar 

  5. Burleson, A. C., and V. T. Turitto. Identification of quantifiable hemodynamic factors in the assessment of cerebral aneurysm behavior. On behalf of the Subcommittee on Biorheology of the Scientific and Standardization Committee of the ISTH. Thromb. Haemost. 76(1):118–123, 1996.

    CAS  PubMed  Google Scholar 

  6. Cannon Albright, L. A., et al. A genealogical assessment of heritable predisposition to aneurysms. J. Neurosurg. 99(4):637–643, 2003.

    Article  PubMed  Google Scholar 

  7. Cebral, J. R., and R. Lohner. Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding technique. IEEE Trans. Med. Imaging 24(4):468–476, 2005.

    Article  PubMed  Google Scholar 

  8. Cebral, J. R., et al. Cerebral aneurysm hemodynamics modeling from 3D rotational angiography. In: Proc. 2004 IEEE International Symposium on Biomedical Imaging: From Nano to Macro, 2004, pp. 944–947.

  9. Cha, K. S., et al. Modeling the interaction of coils with the local blood flow after coil embolization of intracranial aneurysms. J. Biomech. Eng. 129(6):873–879, 2007.

    Article  PubMed  Google Scholar 

  10. Fernandez, M. A., J.-F. Gerbeau, and V. Martin. Numerical simulation of blood flows through a porous interface. ESAIM: Math. Model. Numer. Anal. 42(2008):961–990, 2008.

    Article  Google Scholar 

  11. Humphrey, J. D. Cardiovascular Solid Mechanics: Cells, Tissues, and Organs. New York: Springer, 2002, 757 pp.

    Google Scholar 

  12. Jou, L. D., D. Saloner, and R. T. Higashida. Determining intra-aneurysmal flow for coiled cerebral aneurysms with digital fluoroscopy. Biomed. Eng. Appl. Basis Commun. 16:43–48, 2004.

    Article  Google Scholar 

  13. Kakalis, N. M., et al. The haemodynamics of endovascular aneurysm treatment: a computational modelling approach for estimating the influence of multiple coil deployment. IEEE Trans. Med. Imaging 27(6):814–824, 2008.

    Article  PubMed  Google Scholar 

  14. Kallmes, D. F., et al. A new endoluminal, flow-disrupting device for treatment of saccular aneurysms. Stroke 38(8):2346–2352, 2007.

    Article  PubMed  Google Scholar 

  15. Kim, S. H., et al. Endovascular treatment by using double stent method for ruptured vertebral artery dissecting aneurysms. J. Korean Neurosurg. Soc. 38:132–135, 2005.

    Google Scholar 

  16. Kim, M., et al. Quantification of hemodynamic changes induced by virtual placement of multiple stents across a wide-necked basilar trunk aneurysm. Neurosurgery 61(6):1305–1312, 2007; discussion 1312–1313.

    Article  PubMed  Google Scholar 

  17. Kim, M., et al. Comparison of two stents in modifying cerebral aneurysm hemodynamics. Ann. Biomed. Eng. 36(5):726–741, 2008.

    Article  PubMed  Google Scholar 

  18. Lieber, B. B., A. P. Stancampiano, and A. K. Wakhloo. Alteration of hemodynamics in aneurysm models by stenting: influence of stent porosity. Ann. Biomed. Eng. 25(3):460–469, 1997.

    Article  CAS  PubMed  Google Scholar 

  19. Meng, H., et al. A model system for mapping vascular responses to complex hemodynamics at arterial bifurcations in vivo. Neurosurgery 59(5):1094–1100, 2006; discussion 1100–1101.

    PubMed  Google Scholar 

  20. Meng, H., et al. Complex hemodynamics at the apex of an arterial bifurcation induces vascular remodeling resembling cerebral aneurysm initiation. Stroke 38(6):1924–1931, 2007.

    Article  PubMed  Google Scholar 

  21. Mitsos, A. P., et al. Haemodynamic simulation of aneurysm coiling in an anatomically accurate computational fluid dynamics model: technical note. Neuroradiology 50(4):341–347, 2008.

    Article  PubMed  Google Scholar 

  22. Molyneux, A., et al. International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet 360(9342):1267–1274, 2002.

    Article  PubMed  Google Scholar 

  23. Nguyen, T. N., et al. Comparison of ruptured vs unruptured aneurysms in recanalization after coil embolization. Surg. Neurol. 68(1):19–23, 2007.

    Article  PubMed  Google Scholar 

  24. Radaelli, A. G., et al. Reproducibility of haemodynamical simulations in a subject-specific stented aneurysm model—a report on the Virtual Intracranial Stenting Challenge 2007. J Biomech 41(10):2069–2081, 2008.

    Article  CAS  PubMed  Google Scholar 

  25. Reymond, P., et al. Validation of a one-dimensional model of the systemic arterial tree. Am. J. Physiol. Heart Circ. Physiol. 297(1):H208–H222, 2009.

    Article  CAS  PubMed  Google Scholar 

  26. Sadasivan, C., et al. Treatment of rabbit elastase-induced aneurysm models by flow diverters: development of quantifiable indexes of device performance using digital subtraction angiography. IEEE Trans. Med. Imaging 28(7):1117–1125, 2009.

    Article  PubMed  Google Scholar 

  27. Schievink, W. I., et al. Intracranial aneurysm surgery in Ehlers-Danlos syndrome type IV. Neurosurgery 51(3):607–611, 2002; discussion 611–613.

    Article  PubMed  Google Scholar 

  28. Vernooij, M. W., et al. Incidental findings on brain MRI in the general population. N. Engl. J. Med. 357(18):1821–1828, 2007.

    Article  CAS  PubMed  Google Scholar 

  29. Wailliez, C. and G. Coussement. CFD Study of Multilayer Stent Haemodynamics Effects in Abdominal Aortic Aneurysms. www.cardiatis.com.

  30. Wang, Z., et al. Molecular alterations associated with aneurysmal remodeling are localized in the high hemodynamic stress region of a created carotid bifurcation. Neurosurgery 65(1):169–177, 2009; discussion 177–178.

    Article  PubMed  Google Scholar 

  31. Weir, B. K., et al. Cigarette smoking as a cause of aneurysmal subarachnoid hemorrhage and risk for vasospasm: a report of the Cooperative Aneurysm Study. J. Neurosurg. 89(3):405–411, 1998.

    Article  CAS  PubMed  Google Scholar 

  32. Wiebers, D. O., et al. Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment. Lancet 362(9378):103–110, 2003.

    Article  PubMed  Google Scholar 

  33. Zenteno, M. A., et al. Sole stenting bypass for the treatment of vertebral artery aneurysms: technical case report. Neurosurgery 57(1 Suppl):E208, 2005; discussion E208.

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

This work was generated in the framework of the @neurIST Project, which is co-financed by the European Commission through the contract no. IST-027703. This work has also been partially supported by StrokeLab Inc., Geneva, Switzerland.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to L. Augsburger.

Additional information

Associate Editor Aleksander S. Popel oversaw the review of this article.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Augsburger, L., Reymond, P., Rufenacht, D.A. et al. Intracranial Stents Being Modeled as a Porous Medium: Flow Simulation in Stented Cerebral Aneurysms. Ann Biomed Eng 39, 850–863 (2011). https://doi.org/10.1007/s10439-010-0200-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10439-010-0200-6

Keywords

Navigation