Nephrotoxic effects in high-risk patients undergoing angiography

N Engl J Med. 2003 Feb 6;348(6):491-9. doi: 10.1056/NEJMoa021833.

Abstract

Background: The use of iodinated contrast medium can result in nephropathy. Whether iso-osmolar contrast medium is less nephrotoxic than low-osmolar contrast medium in high-risk patients is uncertain.

Methods: We conducted a randomized, double-blind, prospective, multicenter study comparing the nephrotoxic effects of an iso-osmolar, dimeric, nonionic contrast medium, iodixanol, with those of a low-osmolar, nonionic, monomeric contrast medium, iohexol. The study involved 129 patients with diabetes with serum creatinine concentrations of 1.5 to 3.5 mg per deciliter who underwent coronary or aortofemoral angiography. The primary end point was the peak increase from base line in the creatinine concentration during the three days after angiography. Other end points were an increase in the creatinine concentration of 0.5 mg per deciliter or more, an increase of 1.0 mg per deciliter or more, and a change in the creatinine concentration from day 0 to day 7.

Results: The creatinine concentration increased significantly less in patients who received iodixanol. From day 0 to day 3, the mean peak increase in creatinine was 0.13 mg per deciliter in the iodixanol group and 0.55 mg per deciliter in the iohexol group (P=0.001; the increase with iodixanol minus the increase with iohexol, -0.42 mg per deciliter [95 percent confidence interval, -0.73 to -0.22]). Two of the 64 patients in the iodixanol group (3 percent) had an increase in the creatinine concentration of 0.5 mg per deciliter or more, as compared with 17 of the 65 patients in the iohexol group (26 percent) (P=0.002; odds ratio for such an increase in the iodixanol group, 0.09 [95 percent confidence interval, 0.02 to 0.41]). No patient receiving iodixanol had an increase of 1.0 mg per deciliter or more, but 10 patients in the iohexol group (15 percent) did. The mean change in the creatinine concentration from day 0 to day 7 was 0.07 mg per deciliter in the iodixanol group and 0.24 mg per deciliter in the iohexol group (P=0.003; value in the iodixanol group minus the value in the iohexol group, -0.17 mg per deciliter [95 percent confidence interval, -0.34 to -0.07]).

Conclusions: Nephropathy induced by contrast medium may be less likely to develop in high-risk patients when iodixanol is used rather than a low-osmolar, nonionic contrast medium.

Publication types

  • Clinical Trial
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Angiography / adverse effects
  • Contrast Media / adverse effects*
  • Creatinine / blood*
  • Diabetes Mellitus / blood
  • Double-Blind Method
  • Female
  • Humans
  • Iohexol / adverse effects*
  • Kidney / drug effects*
  • Kidney Diseases / blood
  • Kidney Diseases / chemically induced
  • Male
  • Osmolar Concentration
  • Prospective Studies
  • Risk Factors
  • Triiodobenzoic Acids / adverse effects*

Substances

  • Contrast Media
  • Triiodobenzoic Acids
  • Iohexol
  • Creatinine
  • iodixanol