Diagnostic accuracy of MRI in adults with suspect brachial plexus lesions: a multicentre retrospective study with surgical findings and clinical follow-up as reference standard

Eur J Radiol. 2012 Oct;81(10):2666-72. doi: 10.1016/j.ejrad.2011.10.007. Epub 2011 Nov 8.

Abstract

Objective: To evaluate brachial plexus MRI accuracy with surgical findings and clinical follow-up as reference standard in a large multicentre study.

Materials and methods: The research was approved by the Institutional Review Boards, and all patients provided their written informed consent. A multicentre retrospective trial that included three centres was performed between March 2006 and April 2011. A total of 157 patients (men/women: 81/76; age range, 18-84 years) were evaluated: surgical findings and clinical follow-up of at least 12 months were used as the reference standard. MR imaging was performed with different equipment at 1.5 T and 3.0 T. The patient group was divided in five subgroups: mass lesion, traumatic injury, entrapment syndromes, post-treatment evaluation, and other. Sensitivity, specificity with 95% confidence intervals (CIs), positive predictive value (PPV), pre-test-probability (the prevalence), negative predictive value (NPV), pre- and post-test odds (OR), likelihood ratio for positive results (LH+), likelihood ratio for negative results (LH-), accuracy and post-test probability (post-P) were reported on a per-patient basis.

Results: The overall sensitivity and specificity with 95% CIs were: 0.810/0.914; (0.697-0.904). Overall PPV, pre-test probability, NPV, LH+, LH-, and accuracy: 0.823, 0.331, 0.905, 9.432, 0.210, 0.878.

Conclusions: The overall diagnostic accuracy of brachial plexus MRI calculated on a per-patient base is relatively high. The specificity of brachial plexus MRI in patients suspected of having a space-occupying mass is very high. The sensitivity is also high, but there are false-positive interpretations as well.

Publication types

  • Multicenter Study

MeSH terms

  • Brachial Plexus / pathology*
  • Brachial Plexus Neuropathies / pathology*
  • Female
  • Follow-Up Studies
  • Humans
  • Italy
  • Magnetic Resonance Imaging / standards*
  • Male
  • Middle Aged
  • Reference Standards
  • Reproducibility of Results
  • Retrospective Studies
  • Sensitivity and Specificity