Grading of cerebral glioma with multiparametric MR imaging and 18F-FDG-PET: concordance and accuracy

Eur Radiol. 2014 Feb;24(2):380-9. doi: 10.1007/s00330-013-3019-3.

Abstract

Objectives: To retrospectively evaluate concordance rates and predictive values in concordant cases among multiparametric MR techniques and FDG-PET to grade cerebral gliomas.

Methods: Multiparametric MR imaging and FDG-PET were performed in 60 consecutive patients with cerebral gliomas (12 low-grade and 48 high-grade gliomas). As the dichotomic variables, conventional MRI, minimum apparent diffusion coefficient in diffusion-weighted imaging, maximum relative cerebral blood volume ratio in perfusion-weighted imaging, choline/creatine ratio and (lipid and lactate)/creatine ratio in MR spectroscopy, and maximum standardised uptake value ratio in FDG-PET in low- and high-grade gliomas were compared. Their concordance rates and positive/negative predictive values (PPV/NPV) in concordant cases were obtained for the various combinations of multiparametric MR techniques and FDG-PET.

Results: There were significant differences between low- and high-grade gliomas in all techniques. Combinations of two, three, four, and five out of the five techniques showed concordance rates of 77.0 ± 4.8%, 65.5 ± 4.0%, 58.3 ± 2.6% and 53.3%, PPV in high-grade concordant cases of 97.3 ± 1.7%, 99.1 ± 1.4%, 100.0 ± 0% and 100.0% and NPV in low-grade concordant cases of 70.2 ± 7.5%, 78.0 ± 6.0%, 80.3 ± 3.4% and 80.0%, respectively.

Conclusion: Multiparametric MR techniques and FDG-PET have a concordant tendency in a two-tiered classification for the grading of cerebral glioma. If at least two examinations concordantly indicated high-grade gliomas, the PPV was about 95%.

Key points: • Modern imaging techniques can help predict the aggressiveness of cerebral gliomas. • Multiparametric MRI and FDG-PET have a concordant tendency to grade cerebral gliomas. • Their high-grade concordant cases revealed at least 95 % positive predictive values. • Their low-grade concordant cases revealed about 70–80% negative predictive values.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Brain Neoplasms / diagnosis*
  • Diffusion Magnetic Resonance Imaging / methods*
  • Female
  • Fluorodeoxyglucose F18*
  • Glioma / diagnosis*
  • Humans
  • Male
  • Middle Aged
  • Neoplasm Staging / methods*
  • Positron-Emission Tomography / methods*
  • Predictive Value of Tests
  • Radiopharmaceuticals
  • Retrospective Studies

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18