Evaluation of image quality and dose reduction of 80 kVp neck computed tomography in patients with suspected peritonsillar abscess

Clin Radiol. 2015 Aug;70(8):e67-73. doi: 10.1016/j.crad.2015.04.009. Epub 2015 Jun 6.

Abstract

Aim: To evaluate neck computed tomography (CT) with a reduced tube voltage of 80 kVp in patients with suspected peritonsillar abscess (PTA) regarding objective and subjective image quality, and the potential for dose reduction.

Materials and methods: Forty-seven patients with clinically suspected PTA were retrospectively analysed. Patients were examined using dual-source CT in dual-energy mode. The objective and subjective image quality of 80 kVp images were compared with linearly blended 120 kVp images (M_0.3; 30% of 80 kV, 70% of 140 kV spectrum). Attenuation of abscess rim enhancement, central necrosis, and several other anatomical landmarks were measured. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and rim-to-abscess CNR (raCNR) were calculated. Radiation dose was assessed as size-specific dose estimates (SSDE). Subjective image quality was assessed according to the European guidelines on quality criteria for CT. Interobserver agreement was calculated using the intraclass correlation coefficient (ICC).

Results: Attenuation of inflamed soft tissue (141.7 ± 16.3 versus 93.7 ± 9.3 HU, p < 0.001), CNR (9.6 ± 4.8 versus 5.6 ± 3.8, p = 0.001), raCNR (14.3 ± 5.9 versus 12.4 ± 4.4, p = 0.02), and subjective image sharpness (3.6 ± 0.6 versus 2.8 ± 0.7, p < 0.001) were significantly increased in the 80 kVp compared to 120 kVp, whereas subjective and objective image noise were significantly increased with 80 kVp acquisition (p < 0.001). Overall interobserver agreement was almost perfect (ICC, 0.87). Calculated SSDE of 80 kVp acquisition was decreased by 49.7% compared to 120 kVp (10.58 ± 0.76 versus 21.04 ± 1.43 mGy, p < 0.001).

Conclusion: Low-tube-voltage 80 kVp neck CT provides increased enhancement of soft-tissue inflammation, CNR, raCNR, and improved abscess delineation in patients with PTA compared to standard 120 kVp acquisition while resulting in a significant reduction of radiation exposure.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Child
  • Child, Preschool
  • Female
  • Humans
  • Male
  • Middle Aged
  • Peritonsillar Abscess / diagnostic imaging*
  • Radiation Dosage
  • Radiographic Image Enhancement / methods*
  • Radiographic Image Interpretation, Computer-Assisted / methods*
  • Retrospective Studies
  • Signal-To-Noise Ratio
  • Tomography, X-Ray Computed / methods*
  • Young Adult