Magnetic Resonance Imaging of the Globe-Tendon Interface for Extraocular Muscles: Is There an "Arc of Contact"?

Am J Ophthalmol. 2018 Oct:194:170-181. doi: 10.1016/j.ajo.2018.07.002. Epub 2018 Jul 19.

Abstract

Purpose: To determine if the "arc of contact" is an accurate approximation of the globe-tendon interface for the biomechanical modeling of extraocular muscle (EOM) force transfer onto the globe.

Methods: At a single academic institution, 18 normal and 14 strabismic subjects were prospectively recruited for surface-coil enhanced magnetic resonance imaging at 312- or 390-μm resolution in axial planes for horizontal EOMs (23 subjects, 26 orbits) and sagittal planes for vertical EOMs (13 subjects, 22 orbits) during large ipsiversive ductions. The measured angle at insertion and the predicted angle assuming an "arc of contact" were compared using paired t tests.

Results: For normal EOMs, the measured angle at insertion was significantly greater than predicted assuming an "arc of contact" for the medial rectus (MR) (5.0 ± 4.8 degrees vs 0.0 ± 0.0 degrees, P = .03), lateral rectus (LR) (4.9 ± 3.0 degrees vs 0.0 ± 0.0 degrees, P = .02), inferior rectus (7.4 ± 4.8 degrees vs 1.2 ± 2.6 degrees, P = .00003), and superior rectus (0.6 ± 1.1 degrees vs 0.0 ± 0.0 degrees, P = .04). In strabismic subjects, the measured angle was significantly greater for the MR in abducens palsy (9.9 ± 4.3 degrees vs 0.5 ± 0.7 degrees, P = .0007) and after MR resection (9.0 ± 6.9 degrees vs 1.2 ± 2.4 degrees, P = .02), but not after LR recession (2.9 vs 0.0 degrees). Single subjects had comparable angles after MR recession, but markedly different angles after MR and LR posterior fixation.

Conclusions: Contrary to the "arc of contact" biomechanical model, normal and postsurgical EOMs are significantly non-tangent to the globe at their scleral insertions. The "arc of contact" should be replaced in biomechanical modeling by the experimentally measured angles at tendon insertions. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Biomechanical Phenomena
  • Eye Movements / physiology
  • Female
  • Humans
  • Magnetic Resonance Imaging*
  • Male
  • Middle Aged
  • Models, Biological
  • Oculomotor Muscles / diagnostic imaging*
  • Oculomotor Muscles / physiology
  • Orbit / diagnostic imaging*
  • Prospective Studies
  • Strabismus / diagnostic imaging*
  • Strabismus / physiopathology
  • Tendons / diagnostic imaging*
  • Young Adult