User profiles for David R. Gilland
David GillandUniversity of Florida Verified email at ufl.edu Cited by 2648 |
Implementation of simultaneous attenuation and detector response correction in SPECT
BMW Tsui, HB Hu, DR Gilland… - IEEE Transactions on …, 1988 - ieeexplore.ieee.org
Simultaneous correction of nonuniform attenuation and detector response was implemented
in single-photon-emission computed tomography (SPECT) image reconstruction. A ray-…
in single-photon-emission computed tomography (SPECT) image reconstruction. A ray-…
Multimodality nuclear medicine imaging in three-dimensional radiation treatment planning for lung cancer: challenges and prospects
…, EF Patz Jr, TG Turkington, RJ Jaszczak, DR Gilland… - Lung cancer, 1999 - Elsevier
The purpose of this study was to determine the utility of quantitative single photon emission
computed tomography (SPECT) lung perfusion scans and F-18 fluorodeoxyglucose positron …
computed tomography (SPECT) lung perfusion scans and F-18 fluorodeoxyglucose positron …
[PDF][PDF] Determination of the optimum filter function for SPECT imaging
DR Gilland, BMW Tsui, WH McCartney… - Journal of Nuclear …, 1988 - Soc Nuclear Med
BACKGROUND Filter Operation The filtering ofSPECT images has been performed at three
different stages of the reconstruction algorithm. Originally, the smoothing filter was combined …
different stages of the reconstruction algorithm. Originally, the smoothing filter was combined …
Fully Bayesian estimation of Gibbs hyperparameters for emission computed tomography data
…, VE Johnson, TG Turkington, DR Gilland… - … on Medical Imaging, 1997 - ieeexplore.ieee.org
In recent years, many investigators have proposed Gibbs prior models to regularize images
reconstructed from emission computed tomography data. Unfortunately, hyperparameters …
reconstructed from emission computed tomography data. Unfortunately, hyperparameters …
Simultaneous reconstruction and motion estimation for gated cardiac ECT
DR Gilland, BA Mair, JE Bowsher… - IEEE Transactions on …, 2002 - ieeexplore.ieee.org
The primary goal of this work has been to develop a processing method for gated cardiac
emission computed tomography (ECT) that simultaneously reconstructs the pixel intensities of …
emission computed tomography (ECT) that simultaneously reconstructs the pixel intensities of …
[PDF][PDF] Design and clinical utility of a fan beam collimator for SPECT imaging of the head
…, GT Gullberg, ER Edgerton, DR Gilland… - Journal of nuclear …, 1986 - Soc Nuclear Med
A long bore fan beam collimator for imaging the head was designed and constructed for a
SPECT system with a rotating scintillation camera. In order to avoid the patient's shoulder …
SPECT system with a rotating scintillation camera. In order to avoid the patient's shoulder …
Estimation of images and nonrigid deformations in gated emission CT
BA Mair, DR Gilland, J Sun - IEEE transactions on Medical …, 2006 - ieeexplore.ieee.org
In this paper, we propose and test a new iterative algorithm to simultaneously estimate the
nonrigid motion vector fields and the emission images for a complete cardiac cycle in gated …
nonrigid motion vector fields and the emission images for a complete cardiac cycle in gated …
Respiratory motion correction in gated cardiac SPECT using quaternion‐based, rigid‐body registration
JG Parker, BA Mair, DR Gilland - Medical physics, 2009 - Wiley Online Library
In this article, a new method is introduced for estimating the motion of the heart due to respiration
in gated cardiac SPECT using a rigid‐body model with rotation parametrized by a unit …
in gated cardiac SPECT using a rigid‐body model with rotation parametrized by a unit …
[PDF][PDF] An evaluation of maximum likelihood-expectation maximization reconstruction for SPECT by ROC analysis
DR Gilland, BMW Tsui, CE Metz… - Journal of Nuclear …, 1992 - Soc Nuclear Med
METhODS Data SImulation The cardiac data simulation method has been previouslyde
scribed (23), and an overview is presented here. The projections of simulated three-…
scribed (23), and an overview is presented here. The projections of simulated three-…
Quantitative SPECT reconstruction of iodine-123 data.
DR Gilland, RJ Jaszczak, KL Greer… - Journal of Nuclear …, 1991 - europepmc.org
Many clinical and research studies in nuclear medicine require quantitation of iodine-123 (123I)
distribution for the determination of kinetics or localization. The objective of this study …
distribution for the determination of kinetics or localization. The objective of this study …