Wall shear stress on ruptured and unruptured intracranial aneurysms at the internal carotid artery

LD Jou, DH Lee, H Morsi… - American Journal of …, 2008 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Hemodynamics is often recognized as one of the major
factors in aneurysm rupture. Flow impingement, greater pressure, and abnormal wall shear …

Self-expandable stent-assisted coiling of wide-necked intracranial aneurysms: a single-center experience

S Akpek, A Arat, H Morsi… - American Journal …, 2005 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Endovascular treatment of wide-necked aneurysms remains
a therapeutic challenge. We conducted this study to evaluate the angiographic results …

Angiographic CT in cerebrovascular stenting

…, B Claus, R Naeini, H Morsi… - American Journal …, 2005 - Am Soc Neuroradiology
We evaluated the feasibility of angiographic CT (ACT) for visualizing metallic stents in three
patients who underwent intracranial (n = 2) or extracranial (n = 1) stent placement to treat …

Hemodynamic relationship between intracranial aneurysm and carotid stenosis: review of clinical cases and numerical analyses

LD Jou, HM Shaltoni, H Morsi, ME Mawad - Neurological research, 2010 - Taylor & Francis
Objective: Coexistence of both an intracranial aneurysm and a stenosis at the same internal
carotid artery is infrequent, but it may complicate therapeutic management of either disease. …

Evaluation of C-arm CT metal artifact reduction algorithm during intra-aneurysmal coil embolization: assessment of brain parenchyma, stents and flow-diverters

…, V Srinivasan, SR Chen, H Shaltoni, H Morsi… - European Journal of …, 2016 - Elsevier
Purpose Flat panel C-arm CT images acquired in the interventional suite provide valuable
information regarding brain parenchyma, vasculature, and device status during the procedure…

Computer-aided planning for endovascular treatment of intracranial aneurysms (CAPETA)

A Mohamed, E Sgouritsa, H Morsi… - Medical Imaging …, 2010 - spiedigitallibrary.org
Endovascular treatment planning of intracranial aneurysms requires accurate quantification
of their geometric parameters, including the neck length, dome height and maximum …

Neck localization and geometry quantification of intracranial aneurysms

E Sgouritsa, A Mohamed, H Morsi… - … Imaging: From Nano …, 2010 - ieeexplore.ieee.org
We present an approach for accurate localization of the neck of intracranial aneurysms and
quantification of their geometry that is useful for their treatment through endovascular …

[HTML][HTML] Extensive bilateral vertebral artery remodeling following treatment of dissection using pipeline embolic device

…, E Momin, LD Jou, H Shaltoni, H Morsi… - Journal of Vascular …, 2014 - ncbi.nlm.nih.gov
Background Cerebral artery dissection remains a significant cause of stroke, and the
mainstay of treatment has been medical management with anticoagulation, although flow-diverting …

Hemodynamics of small aneurysm pairs at the internal carotid artery

LD Jou, H Morsi, HM Shaltoni, ME Mawad - Medical engineering & physics, 2012 - Elsevier
Cerebral aneurysms carry significant risks because rupture-related subarachnoid hemorrhage
leads to serious and often fatal consequences. The rupture risk increases considerably …

Hyperacute Stenting for Acute Ischemic Stroke Is Associated with a High Rate of Symptomatic Intracranial Hemorrhage (P02. 200)

A Fong, E Bershad, H Morsi, H Shaltoni, M Mawad… - 2012 - AAN Enterprises
Objective: To report the safety of acute stent placement in patients with acute ischemic stroke.
Background Patients with large vessel occlusions often fail to recanalize with intravenous rt…